WWW.ZEPHYRONLINE.COM Lux ALU-E43CSX, ALU-E43CWX, ALU-E63CSX, ALU-E63CWX EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DEC21.
DESIGNER LUX ISLAND 2 Lux Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information............................................................................. 4-6 Types of Safety Warnings.................................................................... 4 General Safety...................................................................................4-5 Operation............................................................................................ 6 Electrical Requirements.........................................................
DESIGNER Safety Information LUX ISLAND READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
DESIGNER Safety Information LUX ISLAND READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. ► The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
DESIGNER Installation Instructions LUX ISLAND Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting Roof Cap 6” or 10” round duct* 30” to 72” above cooking surface * 6”: CBI-290C, CBI-600A * 10”: CBI-290C, CBI-600A, PBI-1100B CBE-1000A, PBN-1000A For single internal blowers (CBI-290C, CBI-600A), a minimum of 6” round duct work must be used to maintain maximum air flow efficiency. For dual internal blowers, 10” minimum round duct work must be used for dual internal blowers.
DESIGNER Installation Instructions LUX ISLAND Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. ► Use single wall rigid metal ductwork only. ► Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM Hood Specifications 27-9/16” BOTTOM (43”) 43-5/16”, (63”) 63-1/2” SIDE Remote blower junction box 9” 6-9/16” AC power junction box 4-9/16” 2-5/8” Min. 14” Max.
DESIGNER Installation Instructions LUX ISLAND Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Ceiling Opening Preparation 1. The hood should always be centered over the cooktop. Make sure there is adequate space in the ceiling structure to install the hood and ductwork. 2. The hood should be mounted 30” to 72” above the cooktop for best removal of cooking impurities. Use joist size lumber to frame in around the range hood opening. The ceiling structure must be able to support the weight of the hood (FIG. B).
DESIGNER Installation Instructions LUX ISLAND Hood Support Preparation 1. Construct a wood framing system shown in FIG. D and FIG. E. The structure must be capable of supporting its own weight, plus the weight of the hood. ALU-E43 weighs 65 pounds and ALU-E63 weighs 85 pounds. FIG. E 5-1/2” 5-1/2” B 35-9/16” FIG.
Installation Instructions ZEPHYRONLINE.COM Hood Preparation 1. Push in lock tab behind center of perimeter panel to open the hood, FIG. F. 2. Open the perimeter panels and remove the mesh filters, FIG. G. 3. Remove the central panels, unscrewing the 3/16 x 1/4 screws, FIG. G. 4. Remove the (2) light panels by unscrewing the 3/16 x 1/4 screws (ALU-E43 model only), FIG. H. FIG. F REMOVE (4) MOUNTING SCREWS (3/16 x 1/4 Flat Head) FIG.
DESIGNER Installation Instructions LUX ISLAND Blower Installation Internal Blowers (CBI-290C, CBI-600A, or PBI-1100B) 1. Choose blower ducting outlet. Duct options are from top, side, or front. Refer to page 10 for more details. 2. Remove knockout plate for only one chosen duct outlet position. 3. Attach internal blower plate to blower by (4) M4 x 16 screws provided with internal blower, FIG. I. 4. Install internal blower with blower plate into hood body. Bottom of blower plate hooks into body tabs.
Installation Instructions ZEPHYRONLINE.COM Internal Blower Wire Connections NOTE: This range hood must be properly grounded. This unit should be installed by a qualified electrician in accordance with all applicable national and local electrical codes. Internal Blowers (CBI-290C and CBI-600A) 1. Mount capacitor box to hood body by (2) M4 x 8mm screws from blower hardware package. 2. Connect 6 pin female end from PCB box to 6 pin male end of capacitor box wiring, FIG. L1. 3.
DESIGNER Installation Instructions LUX ISLAND Remote Blower Wire Connections A Remote Blowers (CBE-1000 and PBN-1000A) 1. Connect 6 pin remote blower cable to 6 pin molex plug from internal A component box inside range hood, FIG. N. 2. Run 5 wire power with ground cable from remote blower to the remote blower wiring box, FIG. O. 3. Connect the 5 wire power with ground cable to the remote blower cable wires, FIG. P. 4.
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood CAUTION 2x4 WOOD 2x4 WOOD FRAME FRAME At least two installers are recommended due to the weight and size of the hood. 1. Lift range hood into the ceiling opening. 2. Secure each support frame to the wooden hood support frame using the provided (6 to 10) #6 x 2” screws, FIG. Q. 3. Adjust the height of the telescoping support frame to ensure a tight fit between the hood and finishing ceiling.
DESIGNER Installation Instructions LUX ISLAND Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
Features & Controls ZEPHYRONLINE.COM Laminated Touch Controls 2 Fan speed indicator 8 Bluetooth® Indicator 9 Wi-Fi Indicator 1 Blower On/Off 3 Lights; Low/Medium/High/Off 6 Replace Charcoal Filter Indicator 4 Auto-Off Indicator 2 Fan; 3 speed levels 5 Clean Air Active Indicator 7 Clean Grease Filter Indicator 1. Blower On/Off ► By pressing On/Off, the blower is switched on and off. When switched on, the blower starts up on speed level 1. 2.
DESIGNER Features & Controls LUX ISLAND Laminated Touch Controls 6. Recirculating Mode Reminder - Replace Charcoal Filter ► If this feature is enabled, after 200 hours of fan use, the indicator will illuminate. Press and hold On/Off, Light, and Fan for 3 seconds while the hood is off to enable this feature. Press and hold On/Off and Light for 3 seconds while the hood is off to reset the reminder. 7. Clean Grease Filter ► After 120 hours of fan use, the Clean Grease Filter indicator will illuminate.
Features & Controls ZEPHYRONLINE.COM Zephyr Connect Your range hood is compatible with our Zephyr Connect app. All you need is a WiFi connection with access to the Internet that can reach the location of your range hood. Zephyr Connect allows you to control your range hood from anywhere using a mobile device or your Amazon Alexa or Google Home smart speaker. Zephyr Connect also includes real time diagnostics and provides you with important product information.
DESIGNER Features & Controls LUX ISLAND Zephyr Connect Control Type Power Fan Light Delay-Off Control Type Power Fan Light Delay-Off 24 Amazon Alexa Voice Commands Alexa, turn on [Hood Name] Description Turn on range hood power Alexa, turn off [Hood Name] Turn off range hood power Alexa, increase [Hood Name] Fan Speed Increase fan speed on range hood Alexa, decrease [Hood Name] Fan Speed Decrease fan speed on range hood Alexa, set [Hood Name] Fan Speed to [1-6] Set range hood to specifi
Features & Controls ZEPHYRONLINE.COM RF Remote Control To order the RF remote control, the part number is 14000005. The blue antenna wire needs to be extended for optimal signal. Unwrap the antenna wire and position it behind the duct cover. It does not need to be secured. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
DESIGNER Features & Controls LUX ISLAND RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. U. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote. Maximum remote control communication distance is 15 feet from the hood. FIG.
Maintenance ZEPHYRONLINE.COM Hood & Grease Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
DESIGNER Maintenance LUX ISLAND Removing and Installing the Grease Filter (FIG. W) NOTE: Prior to use, remove the protective film from the filter frame. 1. To remove the aluminum mesh filter, pull down on latch tab to disengage the filter from hood. 2. Tilt the filter downward and remove. 1. To install the aluminum mesh filter, align rear filter tabs with slots in the hood. Pull latch tab down. Push filter into place and release tab. 2. Make sure the filter is securely engaged after installation.
Wiring Diagram ZEPHYRONLINE.COM THERMALLY PROTECTED For Residential Use Only BODY BLACK GREY Internal Blower Wiring Diagram WHITE MOTOR LED LED LED LED RED YELLOW BLUE WHITE BLACK BLACK WHITE BODY GREEN BLACK WHITE Model: ALU-E43CSX ALU-E43CWX Voltage: 120V 60Hz Power consumption Total:Max. 155W @ 1.8A (CBI-290C) Max. 340W @ 3.1A (CBI-600A) Max. 780W @ 6.8A (PBI-1100B) Fan: 125W (CBI-290C) 310W (CBI-600A) 750W (PBI-1100B) Lamp: Max.
DESIGNER Wiring Diagram LUX ISLAND BODY BLACK GREY Internal Blower Wiring Diagram WHITE MOTOR LED LED LED LED RED YELLOW BLUE WHITE BLACK BLACK WHITE BODY GREEN BLACK WHITE Model: ALU-E63CSX ALU-E63CWX Voltage: 120V 60Hz Power consumption Total:Max. 165W @ 1.8A (CBI-290C) Max. 350W @ 3.1A (CBI-600A) Max. 790W @ 6.8A (PBI-1100B) Fan: 125W (CBI-290C) 310W (CBI-600A) 750W (PBI-1100B) Lamp: Max.
Troubleshooting ZEPHYRONLINE.COM Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. The unit is vibrating. Possible Cause Solutions The power source is not turned ON. Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. The switch board or control board is defective. The wires on control board are loose.
DESIGNER Troubleshooting LUX ISLAND Possible Problem The hood is not venting out properly. The unit turns on by itself. Mesh filter is vibrating. Possible Cause Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 30” and 72” range. Close all the windows and doors to eliminate the outside wind flow.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The range hood won’t connect to Wi-Fi. User cannot change Wi-Fi connections. Cannot bind the hood to my Zephyr Connect account. Zephyr Connect app won’t register user inputs. Zephyr Connect app stuck on “Loading”. Possible Cause The user’s router or modem is turned off. The user’s router is connected to a 5 GHz wireless frequency. The user’s coaxial cables are loose. Solutions Turn on the router or modem. Connect to the 2.
DESIGNER List of Parts & Accessories LUX ISLAND Description Replacement Parts Aluminum Mesh Filter (each) Replacement Charcoal Filter LED Light Strip, 10W RF Remote Control RF Remote Control Battery A23 12V Optional Accessories Recirculating Kit Single Internal Blower Dual Internal Blower External Blower In-line Blower Part Number 50200046 Z0F-C002 Z0B-0044 14000005 15000007 ZRC-01LX CBI-290C / CBI-600A PBI-1100B CBE-1000 PBN-1000A To order parts, visit us online at http://store.zephyronline.com.
Limited Warranty ZEPHYRONLINE.COM Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.
DESIGNER Product Registration LUX ISLAND Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Lux ALU-E43CSX, ALU-E43CWX, ALU-E63CSX, ALU-E63CWX EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DEC21.
DESIGNER LUX ÎLE 2 Lux Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité........................................................................ 4-6 Types d’avertissements de sécurité...................................................... 4 Sécurité générale................................................................................4-5 Opération............................................................................................ 6 Exigences électriques.......................................................
DESIGNER Consignes de sécurité LUX ÎLE LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
Consignes de sécurité ZEPHYRONLINE.
DESIGNER Consignes de sécurité LUX ÎLE LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. ► Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
DESIGNER Instructions d’installation LUX ÎLE Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine Chapeau de toit Conduit rond de 6 po ou 10po* 30 po à 72 po au-dessus de la surface de cuisson Pour les ventilateurs internes simples (CBI-290C, CBI-600A), un minimum de conduits ronds de 6 po doit être utilisé pour maintenir une efficacité maximale du débit d’air. Pour les ventilateurs internes doubles, des conduits ronds de 10 po minimum doivent être utilisés pour les ventilateurs internes doubles.
DESIGNER Instructions d’installation LUX ÎLE Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. ► Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM Spécifications de la hotte 27-9/16 po BAS (43 po) 43-5/16 po, (63 po) 63-1/2 po CÔTÉ Boîte de jonction de ventilateur à distance Boîte de jonction d'alimentation CA 20-1/8 po 6-9/16 po 4-9/16 po 9 po 2-5/8 po Min. 14 po Max.
DESIGNER Instructions d’installation LUX ÎLE Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette l’insert doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Préparation de l’ouverture du plafond 1. La hotte doit toujours être centrée sur la table de cuisson. Assurez-vous qu’il y a suffisamment d’espace dans la structure du plafond pour installer la hotte et les conduits. 2. La hotte doit être montée de 30” à 72” au-dessus de la table de cuisson pour une meilleure élimination des impuretés de cuisson. Utilisez du bois de la taille d’une solive pour encadrer l’ouverture de la hotte.
DESIGNER Instructions d’installation LUX ÎLE Préparation du support de hotte 1. Construisez un système de charpente en bois illustré à la FIG. D et FIG. E. La structure doit être capable de supporter son propre poids, plus le poids de la hotte. ALU-E43 pèse 65 livres et ALU-E63 pèse 85 livres. Encadrement 2x4 FIG. E 5-1/2 po 5-1/2 po B Trou pilote 1/8 po (6) 35-9/16 po FIG.
Instructions d’installation ZEPHYRONLINE.COM Préparation de la hotte 1. Poussez la languette de verrouillage derrière le centre du panneau périphérique pour ouvrir le capot, FIG. F. 2. Ouvrez les panneaux périphériques et retirez les filtres à mailles, FIG. G. 3. Retirer les panneaux centraux en dévissant les vis 3/16 x 1/4, FIG. G. 4. Retirez les (2) panneaux lumineux en dévissant les vis 3/16 x 1/4 (modèle ALU-E43 uniquement), FIG. H. FIG. F Retirer (4) vis de montage (3/16 x 1/4 tête plate) FIG.
DESIGNER Instructions d’installation LUX ÎLE Installation du ventilateur Ventilateurs internes (CBI-290C, CBI-600A ou PBI-1100B) 1. Choisissez la sortie du conduit du ventilateur. Les options de conduit sont du haut, du côté ou de l’avant. Reportez-vous à la page 10 pour plus de détails. 2. Retirez la plaque défonçable pour une seule position de sortie de conduit choisie. 3. Fixez la plaque du ventilateur interne au ventilateur à l’aide des (4) vis M4 x 16 fournies avec le ventilateur interne, FIG. I. 4.
Instructions d’installation ZEPHYRONLINE.COM Connexions internes des fils du ventilateur REMARQUES: Cette hotte doit être correctement mise à la terre. Cet appareil doit être installé par un électricien qualifié conformément à tous les codes électriques nationaux et locaux applicables. Ventilateurs internes (CBI-290C et CBI-600A) 1. Montez le boîtier du condensateur sur le corps de la hotte à l’aide de (2) vis M4 x 8 mm de l’emballage du matériel du ventilateur. 2.
DESIGNER Instructions d’installation LUX ÎLE Connexions des fils du ventilateur à distance Souffleurs à distance (CBE-1000 et PBN-1000A) A à 6 broches du boîtier 1. Connectez le câble du ventilateur à distance à 6 broches à la prise molex de composants interne à l’intérieur de la hotte, FIG. N. A 2. Acheminez une alimentation à 5 fils avec un câble de mise à la terre du ventilateur à distance au boîtier de câblage du ventilateur à distance, FIG. O. 3.
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte ATTENTION Cadre en2x4 WOOD bois 2x4 FRAME Au moins deux installateurs sont recommandés en raison du poids et de la taille de la hotte. 1. Soulevez la hotte dans l’ouverture du plafond. 2. Fixez chaque cadre de support au cadre de support de la hotte en bois à l’aide des vis fournies (6 à 10) #6 x 2”, FIG. Q. 3. Ajustez la hauteur du cadre de support télescopique pour assurer un ajustement serré entre la hotte et le plafond de finition.
DESIGNER Instructions d’installation LUX ÎLE Recirculation sans conduit La recirculation sans conduit est destinée aux applications où il n’est pas possible d’installer un conduit d’évacuation. Une fois convertie, la hotte fonctionne comme une hotte à recirculation plutôt que comme une hotte aspirante. Les fumées et les gaz d’échappement de la cuisson sont aspirés et filtrés par un ensemble de filtres à charbon en option. L’air est ensuite purifié et recirculé dans la maison.
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles laminées 2 Indicateur de vitesse du ventilateur 8 Indicateur Bluetooth® 9 Indicateur Wi-Fi 1 Ventilateur marche/arrêt 3 Lumières; Faible/Moyen/Haut/Arrêt 6 Indicateur de remplacement du filtre à charbon 4 Indicateur d'arrêt automatique 2 Ventilateur; 3 niveaux de vitesse 5 Indicateur d'air pur actif 7 Indicateur de nettoyage du filtre à graisse 1. Ventilateur marche/arrêt ► En appuyant sur On/Off, le ventilateur est allumé et éteint.
DESIGNER Fonctionnalités et commandes LUX ÎLE Commandes tactiles laminées 6. Rappel du mode de recirculation - Remplacer le filtre à charbon ► Si cette fonction est activée, après 200 heures d’utilisation du ventilateur, l’indicateur s’allumera. Appuyez et maintenez enfoncés les boutons Marche/Arrêt, Lumière et Ventilateur pendant 3 secondes pendant que la hotte est éteinte pour activer cette fonction.
Fonctionnalités et commandes ZEPHYRONLINE.COM Zephyr Connect Votre hotte est compatible avec notre application Zephyr Connect. Tout ce dont vous avez besoin est une connexion WiFi avec accès à Internet qui peut atteindre l’emplacement de votre hotte. Zephyr Connect vous permet de contrôler votre hotte depuis n’importe où à l’aide d’un appareil mobile ou de votre haut-parleur intelligent Amazon Alexa ou Google Home.
DESIGNER Fonctionnalités et commandes LUX ÎLE Zephyr Connect Type de contrôle Puissance Ventilateur Lumière Délai d'arrêt Type de contrôle Puissance Ventilateur Lumière Délai d'arrêt 24 Commandes vocales Amazon Alexa Alexa, turn on [Hood Name] La description Allumez la hotte Alexa, turn off [Hood Name] Coupez l'alimentation de la hotte Alexa, increase [Hood Name] Fan Speed Augmenter la vitesse du ventilateur sur la hotte Alexa, decrease [Hood Name] Fan Speed Diminuez la vitesse du ventila
Fonctionnalités et commandes ZEPHYRONLINE.COM Télécommande RF Pour commander la télécommande RF, la référence est 14000005. Le fil bleu de l’antenne doit être rallongé pour un signal optimal. Déroulez le fil d’antenne et placez-le derrière le couvercle du conduit. Il n’a pas besoin d’être sécurisé.
DESIGNER Fonctionnalités et commandes LUX ÎLE Télécommande RF Fonctionnalités de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. U. Le support de télécommande peut être inséré dans une prise électrique standard pour un rangement facile. Remarque : le support de télécommande ne charge pas la télécommande RF.
Entretien ZEPHYRONLINE.COM Nettoyage de la hotte et du filtre à graisse Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. ► N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
DESIGNER Entretien LUX ÎLE Retrait et installation du filtre à graisse (FIG. W) REMARQUES: Avant utilisation, retirez le film protecteur du cadre du filtre. 1. Pour retirer le filtre à mailles en aluminium, tirez sur la languette du loquet pour dégager le filtre de la hotte. 2. Inclinez le filtre vers le bas et retirez-le. 1. Pour installer le filtre à mailles en aluminium, alignez les languettes arrière du filtre avec les fentes du capot. Tirez la languette du loquet vers le bas.
Schéma de câblage ZEPHYRONLINE.COM PROTÉGÉ THERMIQUEMENT Pour usage résidentiel seulement CORPS NOIR GRIS Schéma du ventilateur interne BLANC MOTEUR LED LED LED LED ROUGE JAUNE BLEU BLANC NOIR NOIR BLANC CORPS VERT NOIR BLANC Modèle: ALU-E43CSX ALU-E43CWX Voltage: 120V 60Hz Consommation d'énergie Total:Max. 155W @ 1.8A (CBI-290C) Max. 340W @ 3.1A (CBI-600A) Max. 780W @ 6.8A (PBI-1100B) Ventilateur: 125W (CBI-290C) 310W (CBI-600A) 750W (PBI-1100B) Lampe: Max.
DESIGNER Schéma de câblage LUX ÎLE CORPS NOIR GRIS Schéma du ventilateur interne BLANC MOTEUR LED LED LED LED ROUGE JAUNE BLEU BLANC NOIR NOIR BLANC CORPS VERT NOIR BLANC Modèle: ALU-E63CSX ALU-E63CWX Voltage: 120V 60Hz Consommation d'énergie Total:Max. 165W @ 1.8A (CBI-290C) Max. 350W @ 3.1A (CBI-600A) Max. 790W @ 6.8A (PBI-1100B) Ventilateur: 125W (CBI-290C) 310W (CBI-600A) 750W (PBI-1100B) Lampe: Max.
Dépannage ZEPHYRONLINE.COM Problème possible Après l’installation, l’appareil ne fonctionne pas. Cause possible Solutions La source d’alimentation n’est pas allumée. La ligne électrique et le connecteur de verrouillage du câble ne se connectent pas correctement. Les câblages du tableau de commande et du tableau de commande sont déconnectés. Assurez-vous que le disjoncteur et l’alimentation de l’unité sont allumés. Vérifiez que la connexion d’alimentation avec l’unité est correctement connectée.
DESIGNER Dépannage LUX ÎLE Problème possible La hotte ne s’évacue pas correctement. Le filtre vibre. La télécommande RF ne fonctionne pas. Cause possible Utiliser la mauvaise taille de conduit. Changez le conduit à au moins 6 po ou plus pour le ventilateur interne et 8 po ou plus pour le ventilateur externe. La hotte peut être suspendue trop Ajustez la distance entre la table de haut à la table de cuisson. cuisson et le bas de la hotte dans une plage de 30 po et 72 po.
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions Le ventilateur Le connecteur de la lumière LED est fonctionne, mais pas les déconnecté. lumières. Lumière LED défectueuse. Connectez le connecteur de la lumière LED. La hotte ne se connecte Le routeur ou le modem de pas au Wi-Fi. l’utilisateur est désactivé. Le routeur de l’utilisateur est connecté à une fréquence sans fil de 5 GHz. Les câbles coaxiaux de l’utilisateur sont desserrés.
DESIGNER Liste des pièces et accessoires LUX ÎLE La description Pièces de rechange Filtre à mailles en aluminium (chacun) Filtre à charbon de rechange Bande lumineuse LED, 10W Télécommande RF Télécommande RF Batterie A23 12V Accessoires optionnels Rallonge de couvercle de conduit Ventilateur interne simple Ventilateur interne double Ventilateur externe Ventilateur en ligne Numéro d’article 50200046 Z0F-C002 Z0B-0044 14000005 15000007 ZRC-01LX CBI-290C / CBI-600A PBI-1100B CBE-1000 PBN-1000A Pour comma
Garantie limitée ZEPHYRONLINE.COM Garantie limitée POUR OBTENIR UN SERVICE SOUS GARANTIE OU POUR TOUTE QUESTIONS LIÉES AU SERVICE Les clients des États-Unis doivent appeler le: 1-888-880-8368 ou nous contacter à: zephyronline.com/contact Clients du Canada, veuillez appeler: 1-800-361-0799 ou par courriel: service@distinctive-online.
DESIGNER Enregistrement du produit LUX ÎLE Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.