Use, Care, and Installation Guide www.zephyronline.com Twister AK8000AS Tornado I AK8100AS Model number: Serial Number: Date of Purchase: Sales Dealer: APR14.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... 6SHFL¿FDWLRQV ............................................................... Electrical ......................................................................... Installing the Power Pack ........................................ 5 6 7 8 9 10 FEATURES & CONTROLS Slide Controls .................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.com MODELS: AK8000AS AND AK8100AS PARTS SUPPLIED AK8000AS and AK8100AS 1 - Power Pack 0HWDO PHVK ¿OWHU $. $6 'HFRUDWLYH PHVK ¿OWHU $.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 6” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap x( ) = Ft. 7”-10” Round, 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect.90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect.45 0 elbow x( ) = Ft. 6” round to 16 Ft. 3-1/ 4” x 10” rect.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only.
Installation – 6SHFL¿FDWLRQV www.zephyronline.
WARNING $OO (OHFWULFDO ZRUN PXVW EH SHUIRUPHG E\ TXDOL¿HG HOHFWULFLDQ RU SHUVRQ ZLWK VLPLODU WHFKQLFDO NQRZ how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
! CAUTION: At least two installers are required due to the weight and size of the hood. 26 7/8” C/L 1. Install optional AK08xxAS Stainless Steel Liner. Review manual included with liner for more details. 10 5/8” Installation – Installing the Power Pack www.zephyronline.com C/L 2. If no liner is used cut out an opening in the bottom of the cabinet by following the dimensions in FIG 1. cabinet bottom cut-out size FIG 1 3.
III II I 2 Lights Bright/Dim/Off II 0 1 BLOWER ON/OFF/SPEED SELECTION 0 is off, I is low speed, II is medium speed and III is high speed. 2 LIGHTS BRIGHT/DIM/OFF 0 is off, I is dim, and II is bright.
Maintenance – Cleaning and Installing Filters www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser.
Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the power pack functions in air “purifying” mode rather than exhausting the air. Fumes and H[KDXVW IURP FRRNLQJ LV GUDZQ DQG ¿OWHUHG E\ D FKDUFRDO ¿OWHU 7KH DLU LV WKHQ SXUL¿HG DQG UHFLUFXODWHG EDFN into the kitchen.
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly. 4.
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART # Replacement Parts /LJKW %XOE 05 *8 : HDFK 0HWDO 0HVK )LOWHU HDFK 'HFRUDWLYH 0HVK )LOWHU HDFK = % Optional Accessories Liner,30” Liner,36” 5HFLUFXODWLQJ .LW $. $6 21/< AK0800AS AK0836AS =5& To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Ten Year Limited Warranty fo