AP-7622 Access Point Installation Guide
AP-7622 Access Point Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies, Inc., a Zebra Technologies company. © 2016 Symbol Technologies, Inc.
Installation Guide 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.3 Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.4 AP-7622 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.4.
AP-7622 Access Point 5.4.2 International . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.4.3 Access Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 5.5 Power Supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 5.6 Radio Frequency Interference Requirements - FCC . . . . . . . . . . 26 5.6.1 Radio Transmitters - Part 15 . . . . . . . . . . . . . . . . . . . . . . . . 26 5.6.
Installation Guide 5 1 Introduction The Access Point’s unique WiNG 5 software enables the Access Point to function as either a Standalone Access Point, an Adaptive Access Point or a Virtual Controller. If new to Access Point technology, refer to the WiNG Access Point System Reference Guide to familiarize yourself with the feature set supported by the WiNG operating system. The guide is available at www.zebra.com/support. This document is written for the qualified network device installer. 1.
AP-7622 Access Point • 1.4 Verify cable lengths are within the maximum allowable distances for optimal signal transmission. AP-7622 Package Contents An AP-7622 Access Point is available in internal antenna (AP-7622) configurations. An AP-7622 ships with the following: • • 1.4.1 AP-7622 Access Point AP-7622 Quick Install Guide Features An AP-7622 Access Point supports the following feature set: • • • Two RJ-45 connectors (GE1/POE and Console) Three LED indicators (2.4GHz, 5GHZ and BLE) One 2.
Installation Guide 7 2 Hardware Installation 2.1 Installation Instructions An AP-7622 Access Point mounts either on a wall or on a suspended ceiling T-Bar. To prepare for the installation: 1. Match the part number on the purchase order with the part numbers in the packing list and on the case of the Access Point. 2. Verify the contents of the box include the intended AP-7622 Access Point, and the included hardware matches the package contents (see AP-7622 Package Contents on page 6).
AP-7622 Access Point 2.2 Precautions Before installing an AP-7622 Access Point, verify the following: • Your are using the correctly rated power solution for the AP-7622. AP-PSBIAS-2P3-ATR PWR INJECTOR: SINGLE PORT HI-PWR 802.3AT PWR SPLY:100-240 VAC, 12VDC, AC/DC Power Supply 1.0A min, 2.5mm barrel, center positive, maximum operating temperature at least 40°C • • • 2.3 Do not to install the AP-7622 in wet or dusty areas.
Installation Guide 9 reducing the burden of installation and allowing optimal Access Point placement in respect to the intended coverage area. ! ! CAUTION Using a non-compliant injector, or an injector supporting legacy modes will not allow the AP-7622 to function at optimum performance levels. CAUTION Do not plug the AP-PSBIAS-2P3-ATR Power Injector into the Access Point’s Console port. Connecting the Power Injector into the console port can damage the port and void the AP-7622’s product warranty.
AP-7622 Access Point A separate Power Injector is required for each AP-7622 Access Point comprising the network. The Power Injector can be installed free standing, on an even horizontal surface or wall mounted using the power injector’s wall mounting key holes. The following guidelines should be adhered to before cabling the Power Injector to an Ethernet source and an Access Point: • • • Do not block or cover airflow to the Power Injector.
Installation Guide ! 11 CAUTION Ensure AC power is supplied to the Power Injector using an AC cable with an appropriate ground connection approved for the country of operation. To install the Power Injector to an Ethernet data source and an Access Point: 1. Connect the Power Injector to an AC outlet (100VAC to 240VAC). 2. Connect an RJ-45 Ethernet cable between the Power Injector Data & Power Out connector and the Access Point’s GE1/POE port. 3.
AP-7622 Access Point 2. Drill pilot holes at the locations marked on the wall. 3. Cable the Access Point using the Power Injector solution, approved AP-7622 power supply or a POE enabled switch. For Power Injector installations: a. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the Power Injector Data & Power Out connector and the Access Point’s GE1/POE port. b. Connect a RJ-45 CAT5e (or CAT6) Ethernet cable between the network data supply (host) and the Power Injector Data In connector. c.
Installation Guide 2.6 13 Ceiling Mount Instructions A ceiling mount requires holding the AP-7622 up against a T-Bar of a suspended ceiling grid and twisting the unit on to the T-Bar. If deploying the AP-7622 on a sculpted ceiling T-Bar, the Access Point mounting kit (Part No. KT-135628-01) can be used as well. A beam clip is also available to attach the Access Point to a ceiling beam. NOTE Before mounting the AP-7622 on a ceiling, obtain the unit’s default IP address from the backside of the unit.
AP-7622 Access Point 6. Push the back of the Access Point chassis on to the bottom of the ceiling T-Bar. 7. Rotate the Access Point 45 degrees counter-clockwise. The clips click as they fasten to the T-Bar. 8. The Access Point is ready to configure. 2.6.1 AP-7622 Beam Clip When needed, an AP-7622 can also be ceiling mounted using a beam clip. If utilizing a beam clip, attach the beam clip to the AP-7622’s integrated mounting bracket. Then connect the Access Point to the ceiling beam.
Installation Guide 2.7 15 LED Indicators The AP-7622’s three LED activity indicators are located on the front of the housing and are visible through the enclosure. The LEDs provide a status display indicating error conditions, transmission, and network activity for the 5 GHz 802.11ac (amber) radio, 2.4 GHz 802.11n (green) radio and Bluetooth activity (blue) radio. NOTE LED behavior for the AP-7622 are identical in both WLAN and client bridge modes.
AP-7622 Access Point Task Green Amber Blue Sensor with Server Not Connected On 1 second, Off 5 seconds Synced with Amber LED On 1 second, Off 5 seconds Synced with Green LED N/A Locate AP Mode Irregular Blink Rate, Green/Amber/Blue Irregular Blink Rate, Green/Amber/Blue Irregular Blink Rate, Green/Amber/Blue Bluetooth Radio Enabled N/A N/A Solid Blue Bluetooth Radio Disabled N/A N/A Off
Installation Guide 17 3 Basic Access Point Configuration Once the Access Point is installed and powered on, complete the following WiNG Assist configuration steps to get the Access Point up and running with minimal administrative intervention. Startup Assist updates existing settings. To delete or revise existing Startup Assist settings, either rerun Startup Assist or navigate to where those parameters appear in the user interface and update them accordingly.
AP-7622 Access Point If Startup Assist does not automatically display, it can be invoked at any time from the upper-left of the Basic Configuration screen. Note • Startup Assist automatically sets the radio transmit power and enables Auto Channel selection. The Access Point's name is automatically assigned based on the Access Point type and the last three octets of the device's hardcoded MAC address. WLAN 1 and WLAN 2 both use VLAN ID 2200 by default.
Installation Guide 19 Access Point's AP Name as its own. Only one Virtual Controller can be designated. • Country Name - Set the country specific to this Access Point's deployment location. Selecting the correct country is central to legal operation. Each country has its own regulatory restrictions concerning electromagnetic emissions and the maximum RF signal strength that can be transmitted. • Timezone - Use the drop-down menu to specify the geographic timezone where the Access Point is deployed.
AP-7622 Access Point 4 AP-7622 Access Point Specifications 4.1 Electrical Characteristics An AP-7622 Access Point has the following electrical characteristics: Operating Current 12VDC, 1A, 2.5mm barrel connector, center positive & Voltage 4.2 Physical Characteristics An AP-7622 Access Point has the following physical characteristics: Dimensions 7.1 in. L x 6.5 in. W x 1.6 in. H 180 mm L x 165 mm W x 41 mm H Weight 0.85 lbs/0.
Installation Guide 4.3 21 Radio Characteristics The AP-7622 Access Point has the following radio characteristics: Data Rates Supported 802.11b/g: 1,2,5.5,11,6,9,12,18,24,36,48 and 54 Mbps 802.11a: 6,9,12,18,24,36,48, and 54 Mbps 802.11n: MCS 0-15 up to 300 Mbps 802.11ac: MCS 0-9 up to 866.7 Mbps Wireless Medium Direct Sequence Spread Spectrum (DSSS) Orthogonal Frequency Division Multiplexing (OFDM) Network Standards IEEE 802.11a/b/g/n/ac 802.11d and 802.
AP-7622 Access Point 5 Regulatory Information 5.1 Regulatory Information This guide applies to the following Model Number AP-7622. Zebra devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local language translations are available at the following Website: www.zebra.com/support Any changes or modifications to Zebra equipment, not expressly approved by Zebra could void the user's authority to operate the equipment.
Installation Guide 5.2.1 23 Country Selection Select only the country in which the device will be used. Any other selection will make the operation of this device illegal. Country Roaming This device incorporates the International Roaming feature (IEEE802.11d) which will ensure the product operates on the correct channels for the particular country of use. Ad-Hoc Operation (2.4 GHz band) Ad-Hoc operation is limited to Channels 1-11 (2412-2462 MHz). 5.2.
AP-7622 Access Point • Reduce or eliminate excessive force • Keep objects that are used frequently within easy reach • Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures Wireless devices transmit radio frequency energy and may affect medical electrical equipment.
Installation Guide 5.4 25 RF Exposure Guidelines 5.4.1 Safety Information Reducing RF Exposure - Use Properly Only operate the device in accordance with the instructions supplied. 5.4.2 International The device complies with internationally recognized standards covering human exposure to electromagnetic fields from radio devices. For information on “International” human exposure to electromagnetic fields refer to the Zebra Declaration of Conformity (DoC) at: www.zebra.com/doc.
AP-7622 Access Point 5.5 Power Supply Use ONLY a Zebra approved UL LISTED ITE (IEC/EN 60950-1, LPS/SELV) power supply with electrical ratings: Output 12Vdc, min 1A, with a maximum ambient temperature of at least 40 degrees C. Use of alternative power supply will invalidate any approvals given to this unit and may be dangerous. Alternately this device may be powered from a 802.
Installation Guide 5.6.2 27 Radio Frequency Interference Requirements - Canada CAN ICES-3 (B)/NMB-3(B) Radio Transmitters This device complies with Industry Canada's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference; and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
5.8 AP-7622 Access Point Statement of Compliance Zebra hereby declares that this radio equipment is in compliance with Directive 2011/65/EU and 1999/5/EC or 2014/53/EU (2014/53/EU supersedes 1999/5/EC from 13th June 2017). The full text of the EU Declaration of Conformity is available at the following internet address www.zebra.com/doc. 5.
Installation Guide 5.11 29 Other Countries All 2.4GHz and 5GHz Wireless Devices: Australia Use of 5GHz RLAN’s in Australia is restricted in the following band 5.50 – 5.65GHz. Chile Este equipo cumple con la Resolución No 403 de 2008, de la Subsecretaria de telecomunicaciones, relativa a radiaciones electromagnéticas. This device complies with the Resolution Not 403 of 2008, of the Undersecretary of telecommunications, relating to electromagnetic radiation.
AP-7622 Access Point China www.zebra.com/support Eurasian Customs Union Hong Kong In accordance with HKTA1039, the band 5.15GHz - 5.35GHz is for indoor operation only. Mexico Restrict Frequency Range to: 2.450 – 2.4835 GHz. La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.
Installation Guide Taiwan 電磁波曝露量MPE標準值 1mW/cm² ; 送測產品實測值為 : 0.35473 mW/cm² 本產品使用時建議應距離人體 20cm The equipment shall be subject to professional engineering personnel to install and configure, it just can be used, and may not be sold directly to the general consumer. Based on 20cm separation distance to assess the amount of electromagnetic exposure (MPE). For FCC parts, MPE limit 1mW/cm²; Test result is 0.35473 mW/cm² For IC parts, MPE limit 5.4039 W/cm²; Test result is 2.
AP-7622 Access Point Turkey For terminals that support Turkish characters in SMS Release 8 services, the following statement should be printed on the packages and manual of the device: Bu cihaz Türkçe karakterlerin tamam?n? ihtiva eden ETSI TS 123.038 V8.0.0 (veya sonraki sürümün kodu) ve ETSI TS 123.040 V8.1.0 (veya sonraki sürümün kodu) teknik özelliklerine uygundur. This device conforms to technical specification in ETSI TS 123.038 V8.0.0 (or the code of any subsequent release) and ETSI TS 123.
Installation Guide 5.12 33 Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Zebra for recycling. For information on how to return product, please go to: www.zebra.com/weee. Français: Clients de l'Union Européenne: Tous les produits en fin de cycle de vie doivent être retournés à Zebra pour recyclage. Pour de plus amples informations sur le retour de produits, consultez : www.zebra.com/weee.
AP-7622 Access Point Malti: Għal klijenti fl-UE: il-prodotti kollha li jkunu waslu fl-aħħar tal-ħajja ta' l-użu tagħhom, iridu jiġu rritornati għand Zebra għar-riċiklaġġ. Għal aktar tagħrif dwar kif għandek tirritorna l-prodott, jekk jogħġbok żur: www.zebra.com/weee. Românesc: Pentru clienţii din UE: Toate produsele, la sfârşitul duratei lor de funcţionare, trebuie returnate la Zebra pentru reciclare. Pentru informaţii despre returnarea produsului, accesaţi: www.zebra.com/weee.
Installation Guide 35 6 Support If you have a problem with your equipment, contact support for your region. Contact information is available at: www.zebra.com/support When contacting support, please provide the following information: • Serial number of the unit • Model number or product name • Software type and version number Support responds to calls by e-mail, telephone, or fax within the time limits set forth in support agreements.
AP-7622 Access Point 7 Zebra Technologies Corporation ("Zebra") End-User Software License Agreement BY INSTALLING AND/OR USING THIS PRODUCT, YOU ACKNOWLEDGE THAT YOU HAVE READ THIS AGREEMENT, UNDERSTAND IT AND AGREE TO BE BOUND ITS TERMS. IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT, ZEBRA IS NOT WILLING TO LICENSE THE PRODUCT TO YOU, AND YOU MUST NOT INSTALL OR USE THIS PRODUCT.
Installation Guide 37 the Products like any other copyrighted material (e.g., a book or musical recording) except that you may make one copy of the Product solely for back-up purposes. Unauthorized duplication of the Products constitutes copyright infringement, and in the United States is punishable in federal court by fine and imprisonment.
AP-7622 Access Point above exclusions may not apply to you. This Limitation of Liability provision survives the termination of this Agreement and applies notwithstanding any contrary provision in this Agreement. Licensee must bring any action under this Agreement within one (1) year after the cause of action arises. Maintenance Unless provided for in a separate agreement, Zebra shall not be responsible for maintenance or field service of the Products.
Installation Guide 39 written approval of the other party, which will not be unreasonably withheld. Any attempted assignment, delegation, or transfer without the necessary approval will be void.
AP-7622 Access Point OF THE THIRD-PARTY SOFTWARE WILL THEN BE GOVERNED BY THE SEPARATE THIRD-PARTY LICENSE. Open Source Software The Products may contain one or more items of Open Source Software.
Installation Guide 41 8 AP-7622 Access Point China ROHS Compliance 有害物质 部件名称 (Parts) 金属部件 (Metal Parts) 电路模块 (Circuit Modules) 电缆及电缆组件 (Cables and Cable Assemblies) 塑料和聚合物部件 (Plastic and Polymeric Parts) 光学和光学组件 (Optics and Optical Components) 电池 (Batteries) 多溴二苯 醚 (PBDE) O 铅 (Pb) 汞 (Hg) 镉 (Cd) 六价铬 (Cr(VI)) O O O O 多溴联 苯 (PBB) O X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O 本表格依据 SJ/T 11364 的规定编制。 O: 表示该有害物质在该部件所有均质材料中的含量均在 GB/T 26572 规定的限量 要求以下。 X:
AP-7622 Access Point
Installation Guide 43
Zebra Technologies Corporation Lincolnshire, IL 60069 USA Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies, Inc. a Zebra Technologies company. © 2016 Symbol Technologies, Inc.