21-199765-01 Integration Guide Document # MN000026A03 ©2016 ZIH Corp. All rights reserved. Zebra and the stylized Zebra head are trademarks of ZIH Corp., registered in many jurisdictions worldwide. All other trademarks are the property of their respective owners.
1 Introduction 1.1 Background The 21-199765-01 Module is intended as an RFID reader which is integrated into a larger product to provide embedded RFID reader capability. It is intended to use the antenna system of the larger product and can get power and communication from an external source. 1.2 Purpose The purpose of this document is to provide a guideline for product designers when integrating the 21-999765-01 RFID Module. 1.3 Part Number Part Number SKU 21-199765-01 US/Canada RFID Module 1.
accomplished using a half-duplex signal consisting of a modulated reader signal followed by a Continuous Wave (CW) signal. The modulated signal sends data to the tag. The tag decodes this signal and then Backscatters (uplinks) its data during the CW portion of the cycle. The Transmitter (downlink) modulation used for communication with RFID tags is Double Sideband Amplitude Shift Keying (DSB-ASK) or Phase Reversal Amplitude Shift Keying (PR-ASK), depending on tag type and reader operating mode.
2.2 Block Diagram DDR2 SDRAM 128MB – 512MB GPO (x3) GPI (x2) GPIO-OUT Opto-Isolators GPIO 166MHz GPIO-IN Opto-Isolators GPIO SDRC 24MHz NAND Flash 256MB – 1GB USB Host USB Host Port USB Host XCVR USB Hub HSUSB1 60MHz USB Client Port USB0 Factory Test Serial Access (test points) SERIAL RF @ 902 – 928MHz GPMC UART3 SDRAM FLASH 64MB 4MB 8 Port RF Interface RF Switch PA 8 50MHz Microprocessor 124.
4 Specifications 4.1 Physical and Environmental Specifications Parameter Size Weight Base Material Mounting Operating Temperature Storage Temperature Humidity Shock/Vibration ESD Specification 7.52 x 5.52 x 1.4” 1.6 lbs Die Cast Aluminum Custom Bracket -20C to +55C -40C to 70C 5 to 95% non-condensing Mil-Std-810G +8kV Contact/+15kV Air Notes Parameter Frequency Range Transmit Power Specification 902-928 MHz +10 to +31.5dBm Notes US/Canada Limited to +30dBm Conducted at antenna interface.
Air Protocol EPCglobal UHF Class 1 Gen2, ISO 18000-6C Receiver Sensitivity IP Addressing Host Interface Protocol API Support -82 dBm Static and Dynamic LLRP v1.0.1 Host Applications – .NET, C and Java EMDK; Embedded Applications – C & Java SDK 5 Integration Guidelines 5.1 Mounting The 21-199765-01 is to be mounted using a bracket that latches on to the latch on the back of the 21199765-01 Module. There is no requirement for screws or heat sinking once the bracket is installed onto the final product.
5.2.1 Ethernet Connection Using a standard Cat5e/Cat6 UTP cable connect the 21-199765-01 module to an Ethernet switch or PC. If the end application is using POE, a POE injector or Midspan should be connected between the 21199765-01 Ethernet connector and the Ethernet switch/PC. 5.2.
7 Regulatory Requirements Add a Labeling Section and a Documentation Section 7.1 Host Labeling: The FCC and Industry Canada require that the FCC ID and the Canadian Listing ID be visible on the end unit. If the label on the module is not visible when the radio module is installed, the contents of the label must be placed on a permanently attached label on the outside of the device. See example of required labeling for a Host device that contains the radio module, 7.