Model: YX500-PCS Advanced Compliance Solutions FCC ID: SO4YX500-PCS FCC Part 24 Transmitter Certification Test Report FCC ID: SO4YX500-PCS FCC Rule Part: CFR 47 Part 24 Subpart E ACS Report Number: 04-0364-24E Manufacturer: Wireless Extenders Equipment Type: PCS Band Bi-Directional Booster Model: YX500-PCS Manual
Wireless Extenders YX500-PCS Installation Guide
Copyright Notice This manual is copyrighted. All rights reserved. This manual, whole or in part, may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form for distribution. This manual, whole or in part, may not be modified without prior consent, in writing, from Wireless Extenders. Copyright © 2004 by Wireless Extenders, 11450 Technology Circle, Duluth, GA 30097, U.S.A.
Table of Contents YX500-PCS Package Contents .....................................................1 YX500-PCS Product Overview......................................................1 Overview ................................................................................................................. 1 Why Cellular Signals Can be Weak ...................................................................... 2 Safety and Product Warranty Information...................................3 Safety Guidelines.....
YX500-PCS Package Contents Before you begin installing the YX500-PCS, make sure all of the following parts came with your kit: Item Quantity Part# Description 1 1 DMAN-0001 YX500-PCS Installation Guide 2 1 APRD-0001 YX500-PCS Base Unit 3 1 CANT-0002 YX500-PCS Base Unit Antenna 4 1 CANT-0001 YX500-PCS Signal Antenna 5 1 CCBL-0001 35’ White RG6@ 3GHZ Coaxial Cable 6 1 CPSP-0001 YX500-PCS Base Unit Power Supply 8 2 CHDW-0001 Self-tapping 7/8” Philips Screw 9 2 CHDW-0002 Self
home or office. By following the simple instructions in this installation guide, you will soon be enjoying wireless where you want it. Why Cellular Signals Can be Weak There are several obstacles that can contribute to the poor reception you receive in your home or office: Proximity of the Cellular Tower to your Home/Office Unlike the sun, strong cellular signals do not fill the sky from every direction.
Safety and Product Warranty Information Safety Guidelines Please adhere to the following safety guidelines during the installation of the YX500-PCS. Specific Absorption Rate In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be installed such that a minimum separation distance of 8 inches (20cm) is maintained between the radiating element and the user and/or general population.
Grounding the Signal Antenna Make sure that the Signal Antenna is properly grounded if you decide to install it outdoors. This will help protect your property and the Base Unit against lightning strikes during a lightning storm. Securing Cable with a Drip Loop If you install the Signal Antenna outdoors, create a drip loop with the coaxial cable at the point where the cable enters the building. This can be done by twisting and securing the cable into a loop near the entry point.
provided that the system is returned promptly upon discovery of the defect while the product is still under warranty. To obtain service, the system must be: {What is Wireless Extender’s return and repair policy?} Warning: Changes or modifications not expressly approved by Wireless Extenders could void the user’s authority to operate this equipment.
Preparing to Install the YX500-PCS Check the Signal Strength Before installing the YX500-PCS in your home, make sure that your cell phone is able to receive a signal on the outside of your home or in the attic. Like a skylight that brings sunlight into a room, the YX500-PCS can only bring cellular signals into your home if cellular signals are reaching the outside of your home. Simply go outside or go into your attic with your cell phone and check the number of signal bars that are displayed.
coaxial cable will be required. For the best performance, The cable length should not exceed 60 feet. Power Requirements The Base Unit can be plugged into a standard 2prong 110 VAC receptacle using the supplied power supply. Warning: Installation Tools The YX500-PCS base unit should only be used with the supplied power cable. Attempts to use other power cables will void the warranty.
{ insert picture of Signal Antenna and mounting parts} photo Using the supplied mounting parts, install the Signal Antenna. For the best signal reception, the antenna should be installed at the highest possible point in your attic. {insert picture of attic installation} 1 drawing – inserting wire into base with exploded view of screws; 2nd drawing – attaching antenna to a mast 3rd drawing – show Signal Antenna mounted to wood beam and antenna mounted to mast.
and connectors. Installing the Base Unit For the widest possible signal reception, it recommended that you install the YX500-PCS Base Unit in the middle of a room or on an interior wall. This is because the Base Unit uses an omnidirectional antenna, which like a lantern delivers the signal in a circular pattern around the antenna. The Base Unit can either be directly mounted on a wall or set on a furniture piece (e.g., a bookshelf, desk, filing cabinet, end table etc.).
2. Attach the antenna to the Base Unit and position it so that it is at a 90 degrees angle to the Base Unit. 3. Set the Base Unit on a furniture piece. 4. Plug the Base Unit’s power supply into a wall outlet. 5. Turn your on your cell phone and check the signal strength. You should now have wireless where you want it. Note: If you are unable to position the Base Unit so that the LEDs shine a steady green, you may have to move the Base Unit to another location in the room, or mount it on a wall.
4. Holding the Base Unit, adjust its position on the wall until the LEDs shine a steady green. The Base Unit can be mounted on the wall with the antenna pointing to the ceiling or towards the floor. 5. Attach the self-tapping wall/ceiling anchors to the wall and attach the Base Unit. 6. Turn on your cell phone and check the signal strength. You should now have wireless where you want it.
Troubleshooting Base Unit LED Operation Mode Normal / Idle In most cases, problems with the YX500-PCS can be diagnosed using the Base Unit’s LEDs.
Mode User Shutdown LED Settings Power LED = Off Signal LED = Solid Red Install LED = Off Network Caution – Reduced Range Power LED = Solid Green Signal LED = Flashing Red (20 seconds) Install LED = Flashing Red (20 seconds) Action User’s phone/device is too close to the Base Unit. The Base Unit has temporarily shut down to prevent network problems. The Signal Antenna is receiving a strong signal from a nearby cell tower (probably another service provider) and is operating with reduced range.
Technical Specifications Frequency 1850-1990 MHz (PCS only) Networks: CMA, GSM, TDMA Total Signal Gain: 60dB (adaptive) Output Power: < 0.5 Watt EiRP (with included antenna) Base Unit Weight: 1 lb. Base Unit Size: 5” x 7” x 2” Power Input: 90 – 120 VAC 60Hz Power Output: 5VDC, 1.
Safety Precautions CAUTION ! For INDOOR use, an Omni-Directional Antenna with a maximum gain of 8 dBi is authorized for use with this unit. Inside antennas must be positioned to observe minimum separation of 20 cm. (~ 8 in.) from all users and bystanders. For the protection of personnel working in the vicinity of inside (downlink) antennas, the following guidelines for minimum distances between the human body and the antenna must be observed.