User manual

Make sure the end
cannot come un-
hooked when the ma-
chine is emptying.
This could be done
by tying it to the tap
with a piece of string
or attaching it to the
wall.
If the machine is permanently plumbed in, hook
the end of the hose into a standpipe installed
for the purpose. The standpipe must have an
internal diameter of at least 40 mm (1 1/2”) in
order that there is an air gap between the drain
hose and the standpipe. Make sure, that it is
designed in such a way, that the end of the
drain hose cannot be covered with water.
650-800 mm
40 mm
Whether discharging into a sink or a standpipe,
check that the end of the drain hose is neither
too high or too low. The top of the curve in the
hose’s end should be no more than 800 mm
(31.5”), and no less than 650 mm (25.6”)
above floor level.
40mm (1 1/2”) diameter
standpipe
Min 30 cm (12”)
The drain hose can be extended up to total 3,5
m. For the extension piece use a hose with an
internal diameter at least as large as that of the
machine's own hose. Use a suitable hose con-
nector.
Electrical connection
Any electrical work required to install this appli-
ance should be carried out by a qualified elec-
trician or competent person.
Warning! THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability
should this safety measure not be
observed.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the appliance’s rating plate.
Warning! Information on the
electrical connection is given on the
rating plate on the inner edge of the
appliance door.
The appliance is supplied with a 13 amp plug
fitted.
In the event of having to change the fuse in the
plug supplied, a 13 amp ASTA approved
(BS1363/A) fuse must be used.
Should the plug need to be replaced for any
reason, proceed as described below.
The wires in the mains lead are coloured in ac-
cordance with the following code:
Green and Yellow - Earth
Blue- Neutral
Brown- Live
21
www.zanussi.com