User manual

13
Ventilation Requirements
The appliance must have adequate ventilation to ensure
correct operation.
Diagram shows the ventilation requirements when
installed:
A* Under a worktop, or cupboard.
* The clearance space of 10 cm above the appliance
may be reduced to 5 cm providing a clearance space
2.5 cm is left on either side of the appliance.
B When freestanding
Door Reversal
If required the opening direction of the door can be
changed as follows:
To reverse the hinge assembly proceed as follows:
Disconnect the appliance from the electricity supply.
Remove the top hinge cover.
Unscrew the 2 retaining screws, and remove the
hinge from the appliance.
Take the door off.
Remove the screw fixing the lower door holder and
the other screw fixing the lower door holder and the
foot. Then remove the door holder and the foot as
shown in the Figure.
Loosen the screw fixing the foot opposite the lower
door holder in order to remove the foot.
Fix the door holder and the corresponding foot on
the opposite side and then the other loosened foot
at the former place of the door holder as shown in
the Figure.
Please make sure to place the lower foot
below the door holder. The lower foot is
recognizable by its 4 ribs on the outer surface.
Fix the door onto the lower hinge pin.
To fit top door hinge, remove the plastic blanking
plugs carefully, and refit them in the holes left by the
hinge retaining screws.
Refit the top hinge using the 2 retaining screws, tak-
ing care that the edge of the door is parallel with side
of the cabinet.
Replace the hinge cover.
Remove screw covers (if fitted) and handle retaining
screws. Remove blanking plugs on the opposite side
using a punch.
Relocate the handle to the opposite side and refit
retaining screws (covers if fitted), and
push the plas-
tic plugs supplied with the instruction book into the
holes where the handle was previously fitted.