Owner's manual

GB 13
Connections
Ducting Version AirExhaust System
When installingthehood in ductingversion,a rigid or
a exible pipe with the diameter corresponding to the
ange diameter is used in order to connect the hood
to theair outletpiping.
• Fixthepipewithanadequatequantityofpipeclamps
(not supplied).
• Remove possiblecharcoal lters.
Recirculation Version AireOutlet
• Cutaholeø125mminanyshelfthatmaybeposi-
tioned overthe hood.
• Insert theange 10aon thehoodbody outlet.
• Connect the ange to the outlet on the shelf over
the hoodusing aexible orrigid pipe ø120mm.
• Fix thepipe in positionusingsufcient pipe clamps
(not supplied).
• Fixthedirectionalgrille8ontherecirculationairoutlet
using the2 screws12e (2,9x 12,7) provided.
• Ensurethat theactivated charcoalltershave been
inserted.
Electrical Connection
• Connect the hood to the mains through a two-pole
switch havinga contactgap ofat least 3mm.
• When opening the sliding carriage for the rst time
after installing the hood, pull it out briskly until it
clicks.

