Technical information

Fitting the Hood Body
Before starting to fix the hood body,
tighten the two screws Vr located on
the top of the hood body.
Hook the hood body onto the two
4.2x44.4mm screws item 12a.
Fully tighten the screws item 12a.
Using a screw driver and spirit level,
adjust the screws item Vr until the
hood body is level.
Extraction
The cooker hood is more effective when used
in the extraction mode (ducted to the outside).
Venting kits may be purchased through
your retailer or DIY store, and must be
ducted to an outside vent of Ø125mm (5”)
or Ø150mm (6”).
The ducting used must be manufactured
from fire retardent material conforming to the
relevant British Standard or DIN 4102-B1.
When the cooker hood is ducted to the outside
the charcoal filter must be removed.
Recirculation
The cooker hood is supplied specified for use in
the recirculation mode, with the charcoal filter
fitted.
In the recirculation mode contaminated air is
passed through the charcoal filter to be purified
and recirculated into the kitchen through the
grille outlets on either side of the chimney.
To assemble the recirculation duct, place the
recirculation outlet connection item 15 into the
support item 7.3.
Insert the extension ducts item 14.1 into either
side of the recirculation outlet item 15 ensuring
the connections are vertically and horizontally
aligned with the outlets in the chimney.
Connect the recirculation oulet item 15 to the
outlet on top of the hood body using either a
piece of Ø125mm or Ø150mm flexible or rigid
pipe.
Rigid pipe is strongly recommended and should
be used where possible as this will ensure the
best performance while lowering noise.
13
ø 150
14.1
15