User manual

Appliance class: 3
BYPASS DIAMETERS
BURNER Ø BYPASS 1/100 mm
Rapid 42
Semi-rapid 32
Auxiliary 28
GAS BURNERS FOR NATURAL GAS G20/G25 20/25 mbar (BE) - G20 20 mbar (LU)
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Rapid 2,9 0,75 119
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar G31 37 mbar
Rapid 2,7 0,75 86 196 193
Semi-rapid 1,9 0,45 71 138 136
Auxiliary 1,0 0,33 50 73 71
ENERGY EFFICIENCY
PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification ZGO63414BA
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid 54.9%
Right rear - Semi-rapid 54.9%
Left front - Rapid 57.5%
Right front - Auxiliary not applicable
28