User manual

OTHER TECHNICAL DATA
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 8 kW
Gas replacement: G30 (3+) 28-30 mbar = 567 g/h
G31 (3+) 37 mbar = 557 g/h
G30/G31 (3B/P) 30/30 mbar = 567g/h
Electric supply: 220 - 240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car-
tridge fuse
Appliance category: II2H3+
I3B/P (AE)
Gas connection: R 1/2"
Appliance class: 3
GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar G31 37 mbar
Rapid 2,8 0,75 86 204 200
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
GAS BURNERS FOR LPG G30/G31 30/30 mbar - ONLY UNITED ARAB EMIRATES
BURNER
NORMAL POWER
kW
MINIMUM POW-
ER kW
INJECTOR MARK
1/100 mm
NOMINAL GAS FLOW
g/h
Rapid 2,8 0,75 86 204
Semi-rapid 2,0 0,45 71 145
Auxiliary 1,0 0,33 50 73
15