35668-9201 INSTRUCTION BOOKLET INSTALLATION AND SERVICING INSTRUCTIONS GAS HOBS ZGG 642 A ZGG 642 B ZGG 642 W ZGG 642 Y 2 GB
WARNINGS AND GUIDANCE It is most important that this instruction book should be retained with the appliance for future reference. Should the appliance be sold or transferred to another owner, or should you move house and leave the appliance, always ensure that the book is left with the appliance in order that the new owner can get to know the functions of the appliance and the relevant warnings. These warnings are provided in the interest of safety.
CONTENTS SECTION 1 - Instructions for the User Page 5 Description of the Appliance Page 5 Operation Page 6 Maintenance and Cleaning Page 6 Servicing Page 7 Peace of Mind for 24 Months Page 8 SECTION 2 - Instructions for the Installer - Technical Data Page 9 Installation Page 10 Gas Connection Page 10 Installation above Cupboard or Drawer Page 11 Important Safety Requirements Page 12 Electrical Connection Page 13 Wiring Diagram Page 14 Fault Finding Page 15 Commissio
INSTRUCTIONS FOR THE USER INSTALLATION It is mandatory that all operations required for the installation are carried out by a Competent Gas Installer (CORGI registered installers normally meet this criteria), and in accordance with existing rules and regulations. The relevant instructions are to be found in the second section of this manual. This appliance meets the requirements laid down in EEC directive No. 89/336 relating to the suppression of radio and TV interferences.
OPERATION HOB BURNERS To light a burner, turn the relevant knob anticlockwise to maximum position and push down the knob to ignite. Then adjust the flame as required. If the burner does not ignite, turn the control knob to zero, and try again. When switching on the mains, after installation or a power cut, it is quite normal for the spark generator to be activated automatically.
SERVICING If you require service or spare parts, contact your local Zanussi Service Force Centre. Please, carry out the following checks before contacting your local Zanussi Service Force Centre.
PEACE OF MIND FOR 24 MONTHS Zanussi Standard Guarantee Conditions This guarantee is in addition to your statutory and other legal rights.
INSTRUCTIONS FOR THE INSTALLER - TECHNICAL DATA OVERALL DIMENSIONS CUT OUT DIMENSIONS Width: Depth: Thickness: Height: Weight: Width: Depth: 580 mm. 510 mm. 40 mm. 88 mm. 11 Kg. 550 mm. 470 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse. This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical interference.
INSTALLATION IMPORTANT Rectangular cut-out size for hob It is essential that a competent installer is employed to fit this appliance. The manufacturer will not accept liability, should the above instruction or any of the other safety instructions incorporated in this book be ignored. On the end of the shaft, which includes the GJ 1/2" threaded nut, adjustment is fixed so that the washer is interposed between the components as shown in Figure 1.
INSTALLATION ABOVE CUPBOARD OR DRAWER ON/OFF SWITCH B ON/OFF SWITCH C 30 A It is also recommended to carry out the electrical connection to the hob as shown in illustrations A and B. a 60 FLEX OUTLET 20 min If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface.
IMPORTANT SAFETY REQUIREMENTS This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The hob should not be installed in a bed sitting room with a volume of less than 20 m3.
ELECTRICAL CONNECTIONS All electrical connections must be carried out by competent persons in accordance with the current regulations. This appliance is designed to be connected to a 240V 50Hz AC electrical supply. The appliance is fitted with a 3 core flexible supply cord incorporating a moulded 3amp plug top fitted with a 3amp ASTA rated fuse. THIS APPLIANCE MUST BE EARTHED. When replacing the plug top fuse only a 3amp BS1362 ASTA rated replacement should be used.
WIRING DIAGRAM N 220 240 1 2 3 0 4 2 1 L 1. TAPS IGNITOR SWITCHES 2.
FAULT FINDING PRELIMINARY ELECTRICAL SYSTEMS CHECK Blue Green Yellow START Isolate appliance and carry out: A: Earth Continuity check. Neutral Wire Blue ( ) E( ) FUSE Earth Wire Green/Yellow Brown SOCKET (face view) PLUG (with cover removed) N L Blue Brown Green Yellow NO YES Carry out: C: Polarity check. Electricity supply should now be satisfactory. A. EARTH CONTINUITY CHECK appliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale and adjust zero if necessary.
IGNITION SYSTEM / GAS IGNITION Ignitor does not spark YES Check gas supply at burner NO Check plug top fuse and replace if necessary Light burner manually Check by pass simmer adjusted Check polarity and earth continuity of supply point Check position of the electrode Check earth continuity of appliance Check continuity from 'N' on the mains connector block and "O" on the ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check continuity fro
COMMISSIONING When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below. - Turn the gas tap to the MAX position and ignite. - Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below. a) Minimum adjust.screw b) Tap Procedure: Re-ignite the burner and set to MIN.
SERVICING A: Removal Of Hob Top D: Removal Of Burner 1. Remove the panstands and each burner cap and crown. 2. Lift the hob from off the working top. 3. Remove the two self tapping screws from each burner and the two fixing screws on the right hand side of the hob. 1. Follow the procedures in Section A. 2. With the aid a 12mm spanner loosen off the pipe connection nut. 3. From the underside of the hob remove 2 self tapping screws from the burner body. 4.