User manual

mate class indicated on the rating plate of the
appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Location
The appliance should be installed well away
from sources of heat such as radiators, boilers,
direct sunlight etc. Ensure that air can circulate
freely around the back of the cabinet. To ensure
best performance, if the appliance is positioned
below an overhanging wall unit, the minimum
distance between the top of the cabinet and
the wall unit must be at least 100 mm . Ideally,
however, the appliance should not be posi-
tioned below overhanging wall units. Accurate
levelling is ensured by one or more adjustable
feet at the base of the cabinet.
Warning! It must be possible to
disconnect the appliance from the mains
power supply; the plug must therefore be easily
accessible after installation.
A
B
100 mm
min
20 mm
Electrical Connection
Caution! Any electrical work required to
install this appliance should be carried out
by a qualified electrician or competent person.
Warning! This appliance must be earthed.
The manufacturer declines any liability
should these safety measures not be observed.
AB
C
D
E
Important! The wires in the mains lead are
coloured in accordance with the following
code:
A Green and Yellow: Earth
C Brown: Live
D Blue: Neutral
As the colours of the wires in the mains lead of
this appliance may not correspond with the col-
oured markings identifying the terminals in your
plug, proceed as follows:
1. Connect the wire coloured green and yel-
low to the terminal marked either with the
letter “E“ or by the earth symbol
or col-
oured green and yellow.
2. Connect the wire coloured blue to the ter-
minal either marked with the letter “N“ or
coloured black.
3. Connect the wire coloured brown to the
terminal either marked with the “L“ or col-
oured red.
10