User manual

5
EN
EN
Is there enough air circulation space around the freezer?
Is the Super Freeze function activated accidentally?
Termperature is too warm
Has a large amount of food just been added to the freezer?
Is the lid opened often?
Is the temperature control set correctly for the surrounding conditions?
Too much ice has formed
Is the lid not closed completely? See underneath.
Is the water drainage plug correctly positioned?
The lid will not close completely
Is there excessive frost or a package preventing the lid from closing?
Are food packages blocking the lid?
Is the lid seal dirty or sticky?
Does the freezer wobble or seem unstable?
The lid is difficult to open
Is the lid seal dirty or sticky?
Is the valve blocked?
If you still need help, please contact your local Sercive Force Centre.
Service or repair
In cases of breakdown or faults, your freezer must be serviced by an authorized Electrolux Service Centre.
Important! Under no circumstances should you attempt to repair the appliance yourself.
Technical Data
Model BNI 225 BNI 325 BNI 425
ZFC 321 WBB ZFC 330 WBB ZFC 340 WBB
Volume (gross) Litre 213 304 404
Volume (net) Litre 210 300 400
Height without/with roller Cm 86,8 86,8 87,6
Width Cm 79,5 105 132,5
Depth Cm 66,5 66,5 66,5
Weight Kg 39 49 56
Energy consumption/24h kWh/24h 0,78 0,957 1,152
Freezing capacity kg/24h 14 17 19
Hold-over time Hours 28 32 31
Rated power Watt 80 85 105
Voltage Volts 230 230 230
Climatic class SN-T SN-T SN-T
Climatic classification Ambient temperature limits
SN from +10°C to +32°C
N from +16°C to +32°C
ST from +18°C to +38°C
T from +18°C to +43°C
This appliance complies with the following EC Directives:
73/23/EEC of 19. 02. 1973 Low-Voltage Directive
89/336/EEC of 03. 05. 1989 (including Amendment Directive 92/31/EEC - EMC
Directive)