Specifications

15
Important Safety Requirements
This appliance must be installed in accordance with
the Gas Safety (Installation and Use) Regulations
(current addition) and the I.E.E. Wiring Regulations.
Detailed recommendations are contained in the
following British Standard Codes of Practice - B.S.
6172, B.S. 5440: Part 2 and B.S. 6891: Current Editions.
For appliances installed in the Republic of Ireland
please refer to NSAI- Domestic Gas Installation I.S.
813 Current Editions and the ETCI Rules for Electrical
Installations.
Provision for Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be met.
The cooker should not be installed in a bed sitting room
Technical Data
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural Gas 20 mbar
Dimensions
Height 900 mm
Depth 600 mm
Width 600 mm
Oven Capacity 56 litres / 1.97 Cu. ft
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.286 0.062 0.190 0.043 0.095 0.031
NOZZLE REFERENCE 11 9 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 202 47 144 32 72 24
NOZZLE REFERENCE 86 40 71 32 50 28
NATURAL
GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37
mbar
1/100 mm
1/100 mm
VALUE =
Hs 49.92 MJ/Kg
Ws 82.09 MJ/ m
3
VALUE =
Hs 37.78 MJ/m
3
Ws 50.72 MJ/ m
3
Instructions for the Installer
Hob
Rear left burner (semi-rapid) 2.0 kW
Front left burner (rapid) 3.0 kW
Rear right burner (semi-rapid) 2.0 kW
Front right burner (auxiliary) 1.0 kW
Oven
Convection Heating Element 2000 W
Grill Element 1650 W
Convection Fan 30 W
Oven light 25 W
Cooker rating (total) 2055 W
Supply voltage (50 Hz) 230 V
with a volume of less than 20m
3
, if it is installed in a
room of volume less 5m
3
an air vent of effective area
of 110cm
2
is required; if it is installed in a room of
volume between 5m
3
and 10m
3
, an air vent of effective
area 50cm
2
is required, while if the volume exceeds
11m
3
no air vent is required. However, if the room has
a door which opens directly to the outside, no air vent
is required even when the volume is between 5m
3
and
11m
3
.
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland
please refer to the NSAI- Domestic Gas Installation I.S.
813 Current Editions Table Four.