User manual

16
SPECIFICATION NOZZLES
Table no.1
CAT: II 2H3B/P
Burner
Normal
power
(kW)
Economi
c
power
(kW)
Gas Type
Pressu
re
(mbar)
By-
pass
(mm)
Nozzle
diameter
(mm)
Cons
g/h
Rapid
2,60
2,60
2,30
0,78
0,72
0,72
Natural Gas G20
Butan G20
Propan G30
13
20
28-30
0,42
-
-
-
1,24
1,13
0,77
-
-
189,05
Semi-rapid
2,00
2,00
2,00
0,50
0,43
0,43
Natural Gas G20
Butan G20
Propan G30
13
20
28-30
0,32
-
-
-
1,11
0,96
0,71
-
-
145,43
Auxiliary
1,00
1,00
1,00
0,40
0,35
0,35
Natural Gas G20
Butan G20
Propan G30
13
20
28-30
0,29
-
-
-
0,82
0,70
0,50
-
-
72,71
Oven
2,60
2,50
2,60
0,90
0,90
0,90
Natural Gas G20
Butan G20
Propan G30
13
20
28-30
0,50
2,5
1,8
2,5
1,30
1,15
0,80
-
-
189,05
Grill
-
-
-
-
-
-
Natural Gas G20
Butan G20
Propan G30
13
20
28-30
-
-
-
-
-
-
-
-
-
-
-
-
Replace the nozzles of the hob burners
Before any modifications or adapt the range
to a kind of different gas, you must DISCONNECT
the cooker from the electricity supply and ensure
that all control knobs are in the OFF position, and
the appliance has cooled completely.
Hob burners
Remove the pan supports;
Remove the caps and the burner crowns;
Using a No 7 socket spanner unscrew the
nozzles and replace them with those required for
the type of gas in use (see table no. 1).
Reassemble the parts following the same procedure
in reverse.
These burners do not need any primary air regulation.
Adjustment of minimum level for the hob burners
The burner is correctly adjusted when the flame is
stable silent and goes out without any noise.
When changing the type of gas check that the
minimum level is correct. The air admission is correct
when the flame is about 4 mm in length.
The top burners do not need adjustment of primary
air.
Check that, turning the knob quickly from the
maximum position to the minimum one, the flame
does not go out.