User manual

Problem Possible cause Solution
The door is not closed correctly. Refer to "Closing the door".
The temperature regulator is not set
correctly.
Set a higher temperature.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets.
Contact the Service Center.
Technical data
Dimension of the recess
Height 880 mm
Width 560 mm
Depth 550 mm
Rising Time 20 h
Voltage 230-240 V
Frequency 50 Hz
The technical information are situated in the rating plate
on the internal left side of the appliance and in the energy
label.
Installation
Caution! Read the "Safety Information" carefully for
your safety and correct operation of the appliance
before installing the appliance.
Positioning
Install this appliance at a location where the ambient tem-
perature corresponds to the climate class indicated on the
rating plate of the appliance:
Climate
class
Ambient temperature
SN +10°C to + 32°C
N +16°C to + 32°C
ST +16°C to + 38°C
T +16°C to + 43°C
Electrical Connection
Caution! Any electrical work required to install this
appliance should be carried out by a qualified
electrician or competent person.
Warning! This appliance must be earthed.
The manufacturer declines any liability should these
safety measures not be observed.
8
www.zanussi.com