Operation Manual

INSTALLATION
31
The microwave can be fitted in position A, B or C:
INSTALLING THE APPLIANCE
1. Remove all packaging and check carefully for any signs of damage.
2. If the microwave is fitted in position C, ensure that the minimum air gaps are maintained as
shown in the diagram.
3. Secure four cupboard retention blocks in position using the setting template
(TMAPTA004URR0).
4. Fit the appliance into the kitchen cupboard, lift over the bottom/front blocks then push slowly,
and without force, until the front frame of the oven seals against the front opening of the
cupboard.
5. Ensure the appliance is stable and not leaning.
6. Fix the oven in position with the screws provided. The fixing points are located within the
louvre areas at the top and bottom of the oven (see diagram, item 1 on page 7).
7. Fit the frame fastener caps to the four fixing positions (2 spare caps are provided).
8. It is important to ensure that the installation of this product conforms to the instructions in this
operation manual and the conventional oven or hob manufacturer’s installation instructions.
Measurements in (mm)
D
Position B
Position A
Conventional
oven
Position C
Cable clip
POSITION NICHE SIZE
W D H
CHIMNEY Gap between
cupboard & ceiling
A 560 x 550 x 450 20 50
B 560 x 500 x 450 20 50
C 560 x 550 x 460 20 Not applicable
65 mm
5 mm
460 mm
20 mm
min. 20 mm
450 mm
min. 20 mm
450 mm
Conventional
oven
Position A
Position B
Position C
Chimney
Cable clip