Venting
The hood is more effective when used in the
extraction setting (ducted to the outside).
Venting kits may be purchased through
your retailer or DIY store, and must be
ducted to an outside vent of 100mm (4”)
minimum.
The ducting used must be manufactured from
fire retardant material.
When the hood is ducted externally the
charcoal filter must be removed and the
slider control must be in the ducting position.
To Fit the Ducting
1. Open the grille by pressing inwardly on the
actuator bolts at each side of the grille, while
pulling the grille panel downwards. The grille
panel will slide into the intermediate position.
Raise the lower edge of the grille forward through
45° angle until the grille becomes detached from
the slide mechanism.
2. Align the flat sides on the spigot with the recesses
in the top of the casing. Insert and snap fix the
spigot into the casing.
3. Connect the ducting to the spigot and make an
air tight seal.
4. Remove the charcoal filter and ensure the slider
control is in the ducting position.
To Remove the Charcoal Filter
1. Remove the thumb screw through the centre of
the charcoal filter, from the motor support.
2. The charcoal filter can now be removed.
Recirculation
The charcoal filter must be fitted for
recirculation and the slide control must be in
the recirculation position.