User manual

28
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air vent necessary [m
3
]
Auxiliary (A) 2,00
Semirapid (SR)
3,80
Rapid 6,30
Double-ring 6,90
Oven 10,00
Grill 8,00
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H3+
Auxiliary (A) 1,00 0,30 27 50 3
*
Semirapid (SR)
1,90 0,38 29 67 5,7
*
Rapid 3,15 0,60 39 86
Fully open
*
Double-ring 3,45 0,85 47 92
Fully open
*
Oven 5,00 1,10 53 107
Fully open
*
Grill 4,00 98
Fully open
*
Nominal
power
[kW]
Reduced
power
[kW]
Tube ring
opening [mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
G 30 / G 31
28-30/37 mbar
BURNERS
Auxiliary (A) 1,00 0,30 72 1
*
Semirapid (SR)
1,90 0,38 100 2
*
Rapid 3,15 0,60 130
5
*
Double-ring 3,45 0,85 135
5
*
Oven 5,00 1,10 53 160
1,5
*
Grill 4,00 150
3
*
Nominal
power
[kW]
Reduced
power
[kW]
Tube ring
opening [mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
G 20
20 mbar
BURNERS
Adjusted
*
Reference value