6.16 HACCP (Hazard Analysis and Critical Control Point)
This function can only be activated on the controllers with the RTC option  tted, and allows advanced control of the operating
temperature and the recording of any anomalies due to power failures or increases in the operating temperature due to various
causes (breakages, severe operating conditions, operator errors, etc…).
There are two types of HACCP alarm, signalled on the display with the following codes respectively: HA and HF. “HA - if, during
operation, the temperature measured is higher than the threshold set for the parameter AH” (high temperature alarm threshold)
for a time Th higher than the sum of the parameter Ad” (HACCP alarm delay) and the parameter “Htd” (temperature alarm detection
delay), the HA alarm is generated.
“HF” – this occurs after a power failure for an extended time (>1 minute) if, when power returns, the temperature is higher than
the threshold set for the parameter AH” (the absolute value of AH,
if A1”= 0; the relative value equal to AH” + “St”, if A1”= 1.
The following data are saved when the HA or HF event occurs:
hour, minutes and day of the week,
type of alarm,
maximum temperature reached after the activation of the alarm,
duration of the power failure.
The activation of one or both of the alarms causes the HACCP LED to  ash and the display of the alarm code, as well as the recording
of the alarm to the E2PROM and the activation of the alarm relay or buzzer
(if present).
Pressing SET and for more than 5 seconds from the HACCP alarm menu resets the  ashing of the HACCP LED, the HA and/or HF
signal and reinitialises the monitoring of HA.
Pressing the PRG button mutes the buzzer and resets the alarm relay (if present).
The date and time of the last 3 HA and HF alarms can be displayed with 6 parameters: HA, HA1, HA2 and HF, HF1, HF2. The activation
of a new HA or HF alarm shifts the list of the last 3 alarms, deleting the oldest event. The new alarm can be displayed using the
parameter that identi es the most recent alarm, that is, HA or HF.
The counter of the alarm events, HAn or HFn, is increased up to a maximum value of The activation of one or both of the alarms
causes the HACCP LED to  ash and the display of the alarm code, as well as the recording of the alarm to the E2PROM and the
activation of the alarm relay or buzzer (if present).
Pressing SET and down for more than 5 seconds resets the  ashing of the HACCP LED, the HA and/or HF signal and reinitialises the
monitoring of HA.
Pressing the button mutes the buzzer and resets the alarm relay (if present).
The date and time of the last 3 HA and HF alarms can be displayed with 6 parameters: HA, HA1, HA2 and HF, HF1, HF2. The activation
of a new HA or HF alarm shifts the list of the last 3 alarms, deleting the oldest event. The new alarm can be displayed using the
parameter that identi es the most recent alarm, that is, HA or HF.
The counter of the alarm events, HAn or HFn, is increased up to a maximum value of 15.