6. DESCRIPTION OF THE FUNCTIONS
6.1 Models
Below is a list of the functions relating to the various models of controller.
Function M (*) SYFCH (**) A (***) D (***)
temperature display
display second probe with external contact
temperature alarm monitoring
compressor control
defrost with compressor stop
defrost with heater or hot gas
continuous cycle
duty setting
evaporator fans
auxiliary output 1
auxiliary output 2
Tab. 6.a
The controllers can be tted with a maximum of two auxiliary relays. The associated functions are:
• alarm output, normally open or closed;
• auxiliary output;
• light output;
• second evaporator output;
• control output for pump down valve;
• control output for condenser fans;
• second delayed compressor output,
• auxiliary output, with deactivation when OFF;
• light output, with deactivation when OFF;
• no function associated with the output;
• reverse output in control with dead band;
• second compressor step output;
• second compressor step output with rotation.
The controllers can be tted with a maximum of three digital inputs (or three probe inputs).
The associated functions are:
• immediate alarm;
• delayed alarm;
• select probe displayed (model M);
• enable defrost;
• start defrost;
• door switch with compressor and fan shutdown and light management;
• remote ON/OFF;
• curtain switch with set point variation and light management;
• low pressure alarm;
• door switch with fan shutdown and light management;
• direct/reverse selection;
• light sensor and light management;
• door switch with compressor and fans o , without light management;
• door switch with fans o , without light management.
The controllers can be tted with a maximum of ve probes (three of which as alternatives to the digital inputs). The associated
functions are:
• ambient probe (used to calculate the virtual control probe);
• product probe (if necessary, used to calculate the virtual control probe);
• defrost probe (main or secondary evaporator, end defrost on 3 evaporator temperature probes);
• condenser probe (used, if necessary, for condenser fan control).
Other functions that enhance the range of the refrigeration controllers include:
• real time clock, for management of real time defrosts;
• real time clock for HACCP alarms management;
• real time clock for the activation/deactivation of the AUX and LIGHT outputs;
• real time clock for the automatic variation of the set point
6.2 Testing the display and keypad on start-up
When the controller is switched on, a special procedure tests the display and the keypad:
Phase Display Keypad Note
First Display completely OFF for 2 seconds Press PRG for 2 seconds to set the default
values
Second Display completely ON for 2 seconds No e ect
Third Three segments (‘---’) on Pressing each button lights up a speci c
segment
In this phase,
appears to indicate
the presence of the RTC
Fourth Normal operation Normal operation
Tab. 6.b
(*) = ir33 only
(**) = powercompact and ir33 DIN only
(***) = mastercella only