6. DESCRIPTION OF THE FUNCTIONS
6.1 Models
Below is a list of the functions relating to the various models of controller.
Function M (*) SYFCH (**) A (***) D (***)
temperature display

display second probe with external contact

temperature alarm monitoring

compressor control

defrost with compressor stop

defrost with heater or hot gas

continuous cycle

duty setting

evaporator fans

auxiliary output 1

auxiliary output 2

Tab. 6.a
The controllers can be  tted with a maximum of two auxiliary relays. The associated functions are:
alarm output, normally open or closed;
• auxiliary output;
• light output;
second evaporator output;
control output for pump down valve;
control output for condenser fans;
second delayed compressor output,
auxiliary output, with deactivation when OFF;
light output, with deactivation when OFF;
no function associated with the output;
reverse output in control with dead band;
second compressor step output;
second compressor step output with rotation.
The controllers can be  tted with a maximum of three digital inputs (or three probe inputs).
The associated functions are:
• immediate alarm;
• delayed alarm;
select probe displayed (model M);
• enable defrost;
• start defrost;
door switch with compressor and fan shutdown and light management;
• remote ON/OFF;
curtain switch with set point variation and light management;
low pressure alarm;
door switch with fan shutdown and light management;
• direct/reverse selection;
light sensor and light management;
door switch with compressor and fans o , without light management;
door switch with fans o , without light management.
The controllers can be  tted with a maximum of  ve probes (three of which as alternatives to the digital inputs). The associated
functions are:
ambient probe (used to calculate the virtual control probe);
product probe (if necessary, used to calculate the virtual control probe);
defrost probe (main or secondary evaporator, end defrost on 3 evaporator temperature probes);
condenser probe (used, if necessary, for condenser fan control).
Other functions that enhance the range of the refrigeration controllers include:
real time clock, for management of real time defrosts;
real time clock for HACCP alarms management;
real time clock for the activation/deactivation of the AUX and LIGHT outputs;
real time clock for the automatic variation of the set point
6.2 Testing the display and keypad on start-up
When the controller is switched on, a special procedure tests the display and the keypad:
Phase Display Keypad Note
First Display completely OFF for 2 seconds Press PRG for 2 seconds to set the default
values
Second Display completely ON for 2 seconds No e ect
Third Three segments (‘---’) on Pressing each button lights up a speci c
segment
In this phase,
appears to indicate
the presence of the RTC
Fourth Normal operation Normal operation
Tab. 6.b
(*) = ir33 only
(**) = powercompact and ir33 DIN only
(***) = mastercella only