User manual

10
Rectangular cut-out size for hob
560
150 min
480
55 min.
FO 2038
Dimensions are given in mm.
Installation
Cut Out Size
The dimensions of the cut-out are given in the
diagram.
A) End of shaft with nut
B) Washer
C) Adjustable joint
IMPORTANT
This appliance must be installed by qualified
personnel.
The manufacturer will not accept liability,
should the above instructions or any of the
other safety instructions incorporated in
this book be ignored.
Gas Connection
On the end of the shaft (A) , which includes the GJ 1/
2" threaded elbow, an adjustable joint is fixed so that
the washer (B) is fitted between the components as
shown in the diagram.
A drop of paint at both edges of the "L" joint (C) will
evidence that the good seal of the connection has
been tested in the factory.
Before connecting the gas supply pipe to the joint
(C), the installer will ensure that the paint drop is
unbroken and the "L" connector has not been moved
by the vibrations during handling and transportation.
When the final connection has been made, it is
essential that a thorough leak test is carried out on the
hob and installation.
Ensure that the main connection pipe does not exert
any strain on the hob.
FO 1010