19 Manual Module M-G1 33300
release the button, and the rmware update process commences.
If the device is not recognised, if the pop-up window “Target device ID not found” appears, or if the
process fails before 100% is reached, you must restart the update procedure. Repeat all the steps as
described above.
The Status display and the Progress bar show the progress of
the rmware update. The update is completed when the mes-
sage “Complete…100%” or “Complete!!” appears.
During the update process both LEDs on the transmitter glow
constantly. When it is complete, the red LED goes out and you
will hear a brief con rmation melody. Both LEDs on the receiver
also light up; when the process is complete, the green LED
goes out, and the red LED starts ashing.
Switch your transmitter / receiver off, and disconnect the ad-
apter lead.
Caution: after completing an update process, you must in-
itialise the device before using it, i.e. reset it to the factory
default values.
Initialisation:
To initialise the transmitter, or to reset it to the factory default settings, press and hold the BIND / RAN-
GE button on the module while you switch the transmitter on, then release the BIND / RANGE button
again.
Please note:
When initialisation is complete, the transmitter will be in Fail-Safe set-up mode. You can therefore imme-
diately continue by programming your fail-safe settings.
If you previously set your transmitter’s Country setting to “France” mode, you must also re-enter the
Country setting.