Operating instructions

Manual Module M-G1 33300 12
5.2.6 Servo test (RX SERVO TEST)
To switch to the Servo test display, press the ENTER button repeatedly until RX SERVO TEST appears
on the screen
Display-Anzeige Erläuterung Einstellungen
ALL MAX Maximum control surface travel position for all servos 1500 – 2000 usec
ALL Min Minimum control surface travel position for all servos 1000 – 1500 usec
TEST Test procedure START / STOP
ALARM VOLT Displays the set voltage at which the low voltage
warning signal is triggered
3.0 – 6.0 V
Factory setting 3.8 V
ALARM TEMP+ Displays the upper limit value at which the warning
signal is triggered
50 – 80° C
Factory setting 70°C
ALARM TEMP- Displays the lower limit value at which the warning
signal is triggered
-20 – +10° C
Factory setting -10°C
CH OUTPUT TYPE Channel sequence ONCE / SAME / SUMI
/ SUMO
Maximum control surface travel position (ALL MAX): this is where you set the maximum control
surface travel for the servo test
Minimum control surface travel position (ALL min): this is where you set the minimum control sur-
face travel for the servo test
Test procedure (TEST): START initiates the servo test process; STOP halts it again. You start and stop
the test by simultaneously pressing the INC / DEC buttons (dark background disappears)
Receiver low voltage warning (ALARM VOLT): monitors the receiver voltage, and can be set to any
value within the range 3.0 to 6.0 Volt. If the voltage falls to the threshold value, an audible signal is
emitted (continuous beeping), and “VOLT.E” ashes at top right in all the Smartbox’s receiver displays;
at the same time the parameter R-VOLT is displayed in inverse form in the receiver data display (RX
DATAVIEW).
Receiver temperature monitor (ALARM TEMP +/-): monitors the receiver temperature. It is pos-
sible to program both a lower limit value ALARM TEMP- (-20 – +10°C) and an upper limit value
ALARM TEMP+ TEMP (50 – 80°C). If the receiver temperature rises above the maximum value or falls
below the minimum, the unit generates an audible warning (continuous beeping). At the same time all
the Smartbox receiver displays show a ashing “TEMP.E” at top right, and the parameter R-TEM is
shown in inverse form in the receiver data display (RX DATAVIEW).
It is important that the temperature of your receiver always stays within the approved range under all
ight
conditions (ideally between 10 and 55°C; please refer to your RC system instructions). If the tempera-
ture rises above maximum or falls below minimum an audible signal is emitted (continuous beeping)
Channel- (CH OUTPUT TYPE): at this point you can select how the receiver signals are sent to the
outputs.
ONCE: the receiver outputs are transmitted in sequence: recommended for analogue servos. This set-
ting ensures that the servos are automatically operated using a 20 msec cycle - 30 msec in the case
of the twelve-channel receiver (Order No. 33512) - regardless of the value set and displayed in the RX
RX SERVO TEST <
ALL-MAX : 2000usec
ALL-MIN : 1000usec
TEST : STOP
ALARM VOLT : 3.8V
ALARM TEMP+ : 70°C
ALARM TEMP- : 10°C
CH OUTPUT TYPE: ONCE
INC + DEC
INC + DEC
INC
DEC
ENTER
ESC
RX SERVO TEST <
ALL-MAX : 2000usec
ALL-MIN : 1000usec
TEST : STOP
ALARM VOLT : 3.8V
ALARM TEMP+ : 70°C
ALARM TEMP- : 10°C
CH OUTPUT TYPE: ONCE