User manual

47
SPECIFICATION NOZZLES NO. 1
(Cat : I 3+)
Burner
Normal
power
(Kw)
Reduced
power
(Kw)
Gas type
Pressure
(mbar)
Nozzle
diameter
Cons.
(g/h)
RAPID
2,60 0,72
Butane G30
Propane G31
28-30
37
0,86
0,86
188,8
SEMIRAPID
2,00 0,43
Butane G30
Propane G31
28-30
37
0,71
0,71
145,2
AUXILIARY
1,00 0,35
Butane G30
Propane G31
28-30
37
0,50
0,50
72,6
OVEN
3,20 1,00
Butane G30
Propane G31
28-30
37
0,88
0,88
232,4
GRIL
2,50 -
Butane G30
Propane G31
28-30
37
0,80
0,80
181,4
OVEN LAMP REPLACEMENT
Before replacing the lamp take care
that all control knobs be on “off”
position
« ».
Disconnect the appliance; watch that the
oven be cool.
This lamp of 15 W, convection E 14
(230/240V) is a special lamp for “higher”
temperature, up to 300˚C. It is supplied on
order, by your After Sales Service.
The lamp is fixed in front of the oven and is
accessible from inside.
For reaching the lamp:
1. Unscrew the glass lamp protection (fig.
18);
2. Unscrew the lamp;
3. Replace the lamp;
4. Remount the lamp protection
fig.18