Service manual

SOI/DT 2007-02 dmm 46/56 599 38 60-23
Alarm Possible fault Action/machine status Reset
E58
Motor defective; Wiring defective on inverter for motor, inverter board defective,
abnormal motor operation (motor overloaded).
Cycle stops with door locked (after 5 attempts). RESET
E59
Motor defective; Wiring defective on inverter for motor;
Inverter board defective.
Cycle stops with door locked (after 5 attempts). RESET
E5A
Inverter board defective. NTC open (on the inverter board).
Overheating caused by continuous operation or ambient conditions (let appliance cool
down)
Cycle stops with door locked (after 5 attempts). RESET
E5B
Wiring defective, Inverter board defective Cycle stops with door locked (after 5 attempts). RESET
E5C
Inverter board defective, the masters voltage is too high (measure the masters voltage) Cycle stops with door locked (after 5 attempts). RESET
E5D
Line interference, Wiring defective, defective main board or inverter board Cycle stops with door locked (after 5 attempts). RESET
E5E
Defective wiring between main board and inverter board, Defective inverter board,
defective main board.
Cycle stops ON/OFF
E5F
Defective inverter board, Defective wiring, defective main board Cycle stops with door locked (after 5 attempts). RESET
E61
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped. START/RESET
E62
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET
E66
PCB faulty . Safety drain cycle – Cycle stopped with door open. RESET
E68
Earth-leakage between heater and earth. Cycle blocked with door open. RESET
E71
Faulty NTC sensor; Wiring faulty;
PCB faulty.
Heating is skipped. START/RESET
E74
NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty. Heating is skipped. START/RESET
E82
PCB faulty (Wrong configuration data). Selector, wiring ---------------- RESET
E83
PCB faulty (Wrong configuration data). Selector, wiring Cycle cancelled. START/RESET
E91
Wiring faulty; Faulty control/display board
PCB faulty.
---------------- RESET
E92
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Cycle interrupted. OFF/ON START
E93
Incorrect configuration data; PCB faulty. Cycle interrupted. OFF/ON
E94
Incorrect configuration data; PCB faulty. Cycle interrupted. OFF/ON
E95
PCB faulty. Cycle interrupted. RESET
E97
Faulty PCB (Wrong configuration data). Cycle interrupted. RESET
E98
Incompatibility between main board and Inverter Cycle interrupted. OFF/ON
E99
Main PCB. Cycle interrupted. OFF/ON
E9B
Display board.
Cycle interrupted.
Reset
E9C
Display board. Cycle interrupted.
Reset
E9D
Display board. Cycle interrupted.
Reset
E9F