S 301.01-00 11
95.11
PARAMETERS PART VISUALISATION
FOOD SAFE CONTROL (FSC)
MULTIPOINT PROBE CONFIGURATION
As this is a measuring system is mandatory to guarantee
the desired precision, so is necessary to introduce an
OFFSET parameter (one for each probe sensor).
1. Switch the oven on and carry out a LAMP TEST by
simultaneously pressing the buttons A,B and C.
2. Wait until the boiler is pre-heated (the boiler status led on
the control panel will go out).
3. Set a steam cycle (100°C) using the cycle selector or the
key pad depending on the function level.
4. Press and hold down the service buttons “A” and “B” and
at the same time start the cycle by pressing the “START”
button.
5. Release the service buttons “A” and “B” and wait for the
oven to stabilise.
6. Wait for the 6 sensors temperatures to stabilise itself of
MOLTIPOINT probe, by pressing simultaneously and for at
least 3 seconds the buttons HISTORY<< and HISTORY
the display shows the going on values of the different
PT1000 sensors temperatures (fig. 8).
7. When the 6 values of temperature have stabilised by
pressing all three buttons A,B and C simultaneously.
8. Swich off the oven by pressing the button START or ON/
OFF.
At the end of this operation, the oven motherboard memorises
the 6 PT1000 offsets.
If the offset parameters are greater than the threshold, the
error EPT3 appears on the LCD and the probe temperature
display (if used).
F-FACTOR VISUALISATION (fig. 8)
By pressing simultaneously and for at least 3 seconds the
buttons HISTORY<<, HISTORY, and HISTORY>> the
display shows the going on value of the F-factor:
F = x x . x
CORE-PROBE TEMPERATURES (fig. 8)
By pressing simultaneously and for at least 3 seconds the
buttons HISTORY>> and HISTORY the display shows the
going on values of the different PT1000 sensors
temperatures:
T: T1 T2 T3
T4 T5 T6
CORE-PROBE RESISTANCES (fig. 8)
By pressing simultaneously and for at least 3 seconds the
buttons HISTORY>> and PRINTER the display shows the
going on values of the different PT1000 sensors resistances:
R: R1 R2 R3
R4 R5 R6
==-- HACCP 10 : 15
34.5˚C 18-04-01
Fig. 8
CONFIGURAZIONE SPILLONE MULTIPOINT (FSC)
Pressing for the first
time after switching the
oven on carries out a
“LAMP TEST”
Start a steam cycle with
the following buttons
pressed. A continuous
steam cycle will start up
(one which never disactivates
the heating elements)
To display the 6 sensors
temperatures of
MOLTIPOINT probe
(FSC fig. 8)
3 sec
When the 6 temperatures have
stabilised simultaneously
press the three buttons
Fig. 7