0GPROUDA-W-ABO Instruction Manual YS-TR-520FDS Ⅱ -590FDS Ⅱ (PROUD) W-Cylinder UT -Thank you very much for purchasing Yuyama Full Auto Tablet Packer YS-TR-520FDS Ⅱ /590FDS Ⅱ . -Read this manual carefully and use YS-TR-520FDS Ⅱ /590FDS Ⅱ properly. -Store this manual at hand with the guarantee card. Read Pages 3 to 5 “Safety Precautions” carefully before use.
Table of Contents Introduction Maintenance Safety instructions ......................................3 Accessories ................................................7 Names of Each Section..............................8 • Machine appearance .........................8 • Inside the machine .............................9 • W-Cylinder Interior ...........................10 Touch panel .............................................. 11 • Key button ........................................
はじめに Safety instructions ■ Degrees of dangers and damages caused by wrong usage ignoring instructions are categorized and explained in the following symbols. WARNING This symbol indicates that failure to obey this instruction may result in serious injury or death. CAUTION This symbol indicates that failure to obey this instruction may result in injury or only property damage. This symbol is used to “promote awareness.” This symbol is used to indicate “prohibited” actions.
WARNING Do not move your fingers close to the cutter blade. Sharp blades are used for the machine. Do not move your fingers close to the cutter blades. Failure to obey this instruction may result in injury. Failure to obey this instruction may result in burn injury or injury. Prohibited ᅠഥ Do not move your fingers close to the heater roller during paper feed. Failure to obey this may result in burn injury.
CAUTION Be sure to use the genuine power outlet. Use of an outlet with an inapplicable voltage and electric capacitance may result in heat generation and fire. In addition, lack of the power capacity and rapid voltage fluctuations may result in malfunctions. Be sure to use the genuine power outlet. Disconnect the power cord and plug in case of abnormal conditions. Damaged power cord/plug, loosen outlet or piled dust may cause an electric shock, heat generation and fire.
FCC Part15.19 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Part.15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Accessories (1) a (4)e (7) h (2b ) (5) f (i 8) (10) k (11) l (3c ) (6) g (j 9) (13) n (14) o (12) m (15) p (16) p (1) Packing paper (10) Tool box (2) Ink ribbon (black or color) * (3) Half type ink ribbon (black) * (11) Phillips screwdriver (large and small) and straight slot screwdriver (4) Drug basket (12) Wax (5) Key (for upper door) x 2 (13) Printer head cleaner (6) Key (for the sides of the packing machine) x 2 (14) Heater roller cleaning brush (7) Request for packing paper and l
Names of Each Section ■ Machine Appearance a g j b k POWER i c CUTTER d e ① Upper door ② Operation panel ③ DTA tray ④ Adaptive table ⑤ Lower doors ⑥ PC (notebook PC or desktop PC) ⑦ Touch panel ⑧ [Power] switch ⑨ [Cutter] switch ⑩ Loudspeaker ⑪ Door key ⑫ [Emergency] switch 8 h l f
■ Inside the machine s o l mn t r q c k Roller u a b p v j i h g f e d ① Revolver unit 21 [Heater Roller Backward] switch ② Major hopper 22 [Heater Roller Forward] switch ③ Circuit breaker ④ Paper tube shaft ⑤ Packing paper ⑥ Packaging section opening/closing lever ⑦ Paper guide ⑧ Heater roller ⑨ Conveyor ⑩ Final hopper ⑪ Lower section operation panel ⑫ Paper guide pin ⑬ Ribbon tension bar ⑭ Ink ribbon ⑮ Printer head release lever ⑯ Paper end sensor ⑰ Ribbon guide ⑱ Platen roller ⑲ [C
■ W-Cylinder Interior a b c d f ① Upper door ② Operation panel ③ Door key ④ Lower door ⑤ Tablet route unit ⑥ Standby unit 10 e
Touch panel (1) (2) POWER CUTTER (3) (4) (1) Message display Displays the status and operation of the packing machine. (2) Key button Used to operate the packing machine. (P12) (3) Display of prescription information Displays the prescription information for the drug that is now being dispensed (or and status of the packing machine is to be dispensed) and the status of the packing machine. (P13) (4) Display and setting of details Displays the detail of prescription.
■ Key button (1) (2) (3) (4) (5) (6) (7) (8) (10) (9) (11) (12) (1) Switches the mode to the one where dispensing is issued only by the packing machine. Restarts dispensing when the machine is temporarily stopped. (2) Stops dispensing temporarily. (3) Opens/closes the DTA tray. (4) Sets the DTA. (Cannot set the DTA when [Number of DTAs: 2]. (5) Switches the screen to the [Call Cassette] screen. (6) Switches the screen to the [Call Drug] screen.
■ Displaying the prescription Information and the status of the packing machine (1) (12) (2) (3) (4) (5) (6) (7) (8) (9) (11) (10) (1) Number of pouches Displays the number of finished pouches and the number of the remaining pouches during dispensing. (2) Patient ID Displays the patient ID during dispensing. (3) Name of patient Displays the name of the patient during dispensing. (4) Ticket number Displays the ticket number of the drug that is currently being dispensed.
使いかた(基本) Turning on the power Press the power switch,turns on the power of packaging machine. Even when the packing machine has been turned ON, do not start operation until the eating of the heater roller is completed. *Operate the breaker before installing the packing machine or cleaning the printer head. 1. Connect the power plug to the outlet. • Be sure to use an AC100V outlet with the 3P earth. • Do not use a multi-outlet extension cord from a device such as a table tap.
3. Turn [ON] the breaker. • After the breaker has been turned on, close the lower door. 4. Packaging machine power switch on. POWER CUTTER • Wait for a while until packing is ready as the heater roller is heated. • You can start dispensing when [Ready to dispense] is displayed.
Unlocking the upper door You are required to input a password to open the upper door. Open the door after entering the password. Once the password has been entered, you can set the machine so that you can open the door without entering the password or you are required to enter the password every time you open the door. Once the power is turned off, you are required to enter the password again. * Entering a password is required only for the packing machine whose upper door has a lock. 1. Touch [RELEASE].
Refilling tablets The following describes how to refilling tablets. * The cassette varies depending on the size and shape of the tablets. Be sure to refill the tablets specified on the cassette. 1. Touch [CAN FIND]. • The screen is switched to the [Call Cassette] screen. • After touching a shelf number, please search for touch. • The called cassette moves to the front. 2. Open the upper door. • Open the upper door while holding its handle.
3. Remove the cassette. • Remove the cassette by pressing the lock of the cassette until it makes a click sound. 4. Put tablets in the cassette. • Replace the desiccant in the cassette periodically. CAUTION Note the following points when re filling tablets. •Note that foreign materials are not mixed. •Do not put too many tablets. •Make sure that tablets are not put in the backside of the cassette (the part where the tablets are ejected). 5. Touch [QTY].
• Touch [REFILL]. • After refilling, touch [RETURN] to return to the original screen. • [+] and [-] are alternatively displayed by touching the code next to [QTY]. • You can reduce the inventory amount by touching [REFILL] with [-]. 6. Install the cassette. • Insert the cassette all the way. 7. Close the upper door. • Close the upper door while holding its handle.
■ [Refill information entry] You can go to the refill information entry screen by reading the drug name by its barcode and clicking the displayed drug name while the refill screen is displayed. 1. Read the drug name using its barcode and click the displayed drug name. 2. Enter the manufacturing number (up to 20 alphanumeric characters). • Touch the manufacturing number display item and enter alphanumeric characters using the numeric keypad.
3. The manufacturing number is displayed. Enter the expiration date (2-digit Christian era and 4-digit month and day or 2-digit Christian era and 2-digit month). • Touch the expiration date display item and enter a numeric figure using the numeric keypad. • Enter of either the manufacturing number or the expiration date is acceptable. 4. The expiration date is displayed. Touch [ENTER]. 5. You can return to the refill screen. The “ i ” mark is displayed next to the drug name (barcode).
■ When all tablets have been dispensed during dispensing Dispensing stops when all tablets have been dispensed. After refill of tablets is completed ([REFILL] is touched), dispensing automatically resumes. 1. [Cassette empty warning] is displayed on the touch panel and an alarm is issued. (The detail of the short drug is displayed.) 2. Touch [MUTE] to stop the alarm. 3. Refill tablets in the cassette and touch [REFILL]. • [Cassette empty warning] is released and dispensing resumes.
■ When all tablets have been dispensed during dispensing (when the group cassette is empty) This page describes the case when tablets registered in the group cassette are short during dispensing. 1. When the drug for the group cassette is short, the [Next Cass] button is displayed. • Touch [MUTE] to stop the alarm. • Press the [Next Cass] button. • The location number (MB#) of the displayed cassette is changed.
■ [Call Cassette] You can call a desired cassette using its cassette number. When the cassette is placed on the refilling table on the [Call Cassette] screen, the location number where the cassette was attached to is displayed. 1. Touch [CAN FIND]. • Enter the cassette number and then touch [SEARCH]. • The called cassette moves to the front of the tablet rack. • Then refill the drug.
■ [Call Drug] You can call a desired cassette using a drug name. 1. Touch [CAN FIND]. • The screen is switched to the [Call Cassette] screen. • Then touch [Call Drug]. (The screen is switched to the [Call Drug] screen.) • Touch the capital letter of the drug to be called. (1) • Drugs with the selected capital letter are displayed in a list. Touch a desired drug in the list. (2) • Touch [SEARCH]. • The called cassette moves to the front of the tablet rack. • Then refill the drug.
■ [Search] You can search places where any cassette is not attached (used). The cassette condition is displayed by placing the cassette on the refill table on the [Search] screen. 1. Touch [CAN FIND]. • The screen is switched to the [Call Cassette] screen. 2. Touch [SEARCH]. • The screen is switched to the [Search] screen. 3. Search • Select the condition of the cassette to be searched and then touch [SEARCH]. (The cassette size display varies depending on the packing machine type.
■ Details of DTA filling Filling of the drug selected on the DTA drug list screen is displayed. 1. The DTA set wait screen is displayed at the time of issuing a DTA prescription or when the second filling is to be performed after the DTA set. (Up to 13 drugs are displayed at one time.) • If there are 14 drugs or more, press [NEXT PAGE]. • Other drugs are displayed. You can return to the previous screen displaying the 13 drugs by pressing [NEXT PAGE] again.
2. Touch the drug name. 3. You go to the DTA drug list screen. 4. Touch the drug name you want to display. Press the [DETAILS] button while the drug name is displayed within the black frame. 5. How to fill the drug selected in the DTA drug list is displayed. • Press [NEXT PAGE].
6. How to fill the unfilled drug that is next to the currently displayed drug is displayed. • When unequal tablets are to be set, a caution message is displayed. • Press [RETURN]. 7. If you return to this screen by pressing [RETURN] on the DTA details screen, you will notice that the background color for the drug name displaying the filling details have been changed, indicating that the drug has been already browsed. • Set DTA and press [RETURN]. 8. Dispensing starts and DTA starts delivering.