Wireless Communica on Base YS7A01-UC Installa on & User Guide Rev 1.
Thank you for purchasing YoLink products and for entrus ng us with your smart home needs! Your 100% sa sfac on is our goal. If you experience any problems with se ng up your new YoLink Wireless Communica on Base, please give us a chance to assist you, before returning your purchase. We at Customer Support are here for you.If you need any assistance installing , se ng up or using a YoLink product or our app. Find addi onal support and ways to reach us at: www.yosmart.
Contents A. B. C. D. E. F. G. H. I . J. K.
A. In the Box A. Wireless Communica on Base B. Quick Start Guide A. B.
B. Introduc on The YoLink Wireless Communica on Base, works with a detector head (ANKA Smoke & CO Alarm, model: AJ-939/AJ-933/AJ-938). Used in conjunc on with the Smoke & CO Alarm, it converts the Smoke & CO Alarm into a smart alarm device. Add the Wireless Communica on Base to the YoLink app, you can monitor the real- me status of smoke and carbon monoxide in the detec on area, and you can check the historical alarm record (including type, date and me) via the app.
The LED light indicates the current status of the wireless communica on base: Blinking Red Once, then Green Once Device turned on Blinking Red And Green Alternately Restoring to Factory Defaults Blinking Green Connec ng to Cloud Fast Blinking Green Establishing Connec on with YoLink System (YoLink Control) Slow Blinking Green Upda ng Blinking Red Once Device is connected to the cloud and is func oning normally Fast Blinking Red Removing Connec on to YoLink System (YoLink Control) Fast Blinking Red E
C. Set Up C-1. Set Up - First-Time YoLink Users (Exis ng users proceed to C-2. Add Device, next page) 1 Download the YoLink app through Apple App Store or Google Play Store (Search in the store or use the QR code on the right) Apple iPhone or tablet that is iOS 9.0 or higher, or an Android phone or tablet that is Android 4.4 or higher 2 Log in to the YoLink app 1.
C-2. Add Device ” bu on, then scan QR 1 Ta p “ Code on the device. Follow the steps to add the device 2 Press the SET bu on once to turn on the device. The Status LED will blink red once, then green several mes, indica ng your device has connected to the cloud and is ready to use SET Bu on 1. You will need to press the SET bu on once again if the device failed to connect to the cloud 2. Pressing the SET bu on at any other me a er this ini al process will result in the LED blinking red once, only.
D. Installa on (With Detector Head) 1. Please refer to the installa on manual packaged with the detector head (ANKA Smoke & CO Alarm, AJ-939) to complete the installa on of your Smoke & CO Alarm 2.
E. Using the YoLink App (With Detector Head) E-1.
E-2. Details page-1 a. Device Type b. Rename the Device c. Choose a Room for device d. Add/Remove from favorites e. Device History Smoke alarm; CO alarm; extremely high temperature warning and self-test history (self-test passed or detector head failed or failed to communicate with the detector head), logged with date & me f. Alert se ngs - Enable or disable alerts g. Alert interval - Set re-no fica on interval a er an alert (smoke or CO detec on, extremely high temperature warning).
E-2. Details page-2 j. Device Model k. Device EUI (unique) l. Device SN (unique) m. Temperature value - Updates when: 1. SET bu on pressed 2. On a device alert 3. Automa cally within 4 hours maximum n. Connec on Signal Status of wireless communica on base and Hub: Strong; Good; Weak o. Current Ba ery Level - Shown red if ba ery level is low p. Firmware Version - “#### ready now ” indicates a new update is available (refer to page 17 ) q.
E-3.
Device alerts with no fica ons when either of the following condi on is met Extremely High Temperature Exceeding 135°F (57°C) Detector Head Failed Wireless Communica on Base Ba ery is Low Detector Head Ba ery is Low Yo u w i l l n e e d to re p l a c e t h e w i re l e s s communica on base if ba ery is low, and you will need to replace the detector head if ba ery is low 11
E-4. Automa on (Set Up Rules For “If This Then Do That”) Go to the “Smart” screen, tap “Automa on” Wireless Communica on Base can be set as a trigger only, with three trigger op ons: Smoke Alarm; CO Alarm; Extremely High Temperature Alarm a. b-1 b-2 b-5 b.
E-5. Voice Assistants (Under Developing, Not Support Now) C o n n e c t Yo L i n k w i t h t h i r d - p a r t y v o i c e a s s i s t a n t s t o m o n i t o r t h e s t a t u s o f y o u r d e v i c e s through voice commands Tap “ ” in the upper le corner to go to My Profile Go to Se ngs > Voice Assistants for the applicable voice assistant integra on guide YoLink Wireless Communica on Base is integrated with Google Assistant, and is also integrated with IFTTT.
F. About YoLink Control (With Detector Head) YoLink Control is our unique device-to-device control technology. Using YoLink Control, YoLink devices can be controlled without the Hub or an internet connec on. (Use of YoLink Control is op onal; you can use the Automa on feature in the app OR use YoLink Control, but YoLink Control offers the benefit of opera on without the Hub or internet connec on.) One device controls another, directly. A device that sends out commands is called the controller.
2 To c o n fi g u r e a G a s / Wa t e r Va l v e Controller as the responder, ensure the Gas/Water Valve Controller has already been bound to the YoLink app. Using the app, CLOSE the valve ( ve r i f y t h e va l ve i s s h ow n to b e Closed on the app, or press the Close bu on if it is shown as Open) (FOR GAS VALVE CONTROL). Press and hold the SET bu on for 5-10 seconds un l the LED quickly blinks green , then, release the bu on Refer to the Gas/Water Valve Controller manual for more informa on: a.
Opera on When the smoke & CO alarm a c vate s ( S M O K E A L A R M / CO ALARM/ EXTREMELY HIGH TEMPERATURE ALARM), the Yo L i n k G a s / W a t e r V a l v e Controller will now immediately close the valve. The valve will remain closed un l opened via the app or using the SET bu on; the restoral of the smoke & co alarm to normal (no smoke /CO/extremely high temperature detected) does not open the valve More advanced sequences, controlling mul ple outputs (e.g.
F-2.
G. Maintenance G-1. Firmware Update To ensure our customers have the best user experience, we highly recommend you update to the newest version firmware when an update is available In “Firmware”, if a new version is listed as available (#### ready now), click it to start the firmware update process The device's firmware will be updated automa cally within 4 hours (maximum).
G-2. Factory Reset Factory reset will erase all of your se ngs and restore it to factory defaults (Removes access network informa on and YoLink Control se ngs).
H. Specifica ons Input Voltage: 3V DC (2 - AA lithium/Alkaline Non-rechargeable ba ery) Ba ery Life: 10 years Device Current Draw: ≤ 135mA (working), ≤ 5uA (standby) Detec on Contents: Smoke; carbon monoxide; temperature Temperature Value Accuracy: 1 (°F/°C) Detec on Temperature: -4°F-122°F, ±3.6 °F (-20°C-50°C, ±2°C ) Dimensions: Φ4.80 x 0.
I. Troubleshoo ng Symptoms: 1.
J. Warning Please install, operate and maintain the Wireless Communica on Base only as outlined in this manual.
If you have any difficul es installing or using your Wireless Communica on Base, please contact our Customer Service department during business hours: US Live Tech Support: 1-949-825-5958 M-F 9am - 5pm PST Email: service@yosmart.com YoSmart Inc.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons, may cause harmful interference to radio communica ons.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica ons to this equipment. Such modifica ons could void the user’s authority to operate the equipment. FCC RF Radia on Exposure Statement This equipment complies with FCC RF radia on exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or opera ng in conjunc on with any other antenna or transmi er.