User Manual

FN110
Field Wireless Communication Module
IM 01W03B01-01EN
IM 01W03B01-01EN
1st Edition
1. Introduction
Thank you for purchasing the Field Wireless Communication Module.
Your Field Wireless Communication Module was precisely calibrated at the factory before
shipment. To ensure both safety and efficiency, please read this manual carefully before you
operate the instrument.
Regarding This Manual
This manual should be provided to the end user.
The contents of this manual are subject to change without prior notice.
All rights reserved. No part of this manual may be reproduced in any form without Yokogawa’s
written permission.
Yokogawa makes no warranty of any kind with regard to this manual, including, but not limited to,
implied warranty of merchantability and fitness for a particular purpose.
If any question arises or errors are found, or if any information is missing from this manual,
please inform the nearest Yokogawa sales office.
The specifications covered by this manual are limited to those for the standard type under the
specified model number break-down and do not cover custom-made instruments.
Please note that changes in the specifications, construction, or component parts of the
instrument may not immediately be reflected in this manual at the time of change, provided that
postponement of revisions will not cause difficulty to the user from a functional or performance
standpoint.
Safety, Protection, and Modification of this Product
In order to protect the operator, product, and system controlled by the product, observe the
safety precautions described in this manual. If users handle contrary to these instructions, we
cannot guarantee the safety.
Modification of the product is strictly prohibited.
The following safety symbols are used in this manual:
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury or physical damage. It may also be used to alert against unsafe practices.
IMPORTANT
Indicates that operating the hardware or software in this manner may damage it or lead to
system failure.
1.1 Radio Wave
IMPORTANT
This product is equipped with a wireless module which is designated as a certification of
construction type as a wireless facility for 2.4 GHz band low-power data communication system
of the Radio Act.
Refer to “5.2 Regulatory Compliance Statements” for detail.
Due to the designated certification of construction type, users may be subject to legal
punishment in case of:
- Disassembling or modifying the wireless module or antenna in this instrument
Microwave ovens and other industrial, scientific and medical equipment, as well as local wireless
stations (license required) and specific low-power wireless stations (license not required) for
identifying mobile objects used in the production line of a factory, use the same frequency band
as this product. Prevent interference with other wireless stations.
Check that local wireless stations and specific low-power wireless stations are not being used in
the vicinity before using this product.
If this product causes radio interference in a local wireless station used for identifying mobile
objects, change the working frequency or stop the emission of radio waves immediately. For
details on how to prevent radio interference, contact our service office.
Although this product has been designed to resist high frequency electrical noise, if a radio
transceiver is used near the transmitter or its external wiring, this product may be affected by
high frequency noise pickup. To test this, start out from a distance of several meters and slowly
approach this product with the transceiver while observing the measurement loop for noise
effects. Thereafter use the transceiver outside the range where the noise effects were first
observed.
1.2 Warranty
The warranty shall cover the period noted on the quotation presented to the purchaser at the
time of purchase. Problems occurring during the warranty period shall basically be repaired
free of change.
If any problems are experienced with this instrument, the customer should contact the
Yokogawa representative from which this instrument was purchased or the nearest
Yokogawa office.
If a problem arises with this instrument, please inform us of the nature of the problem and the
circumstances under which it developed, including the model specification and serial number.
Any diagrams, data and other information you can include in your communication will also be
helpful.
The party responsible for the cost of fixing the problem shall be determined by Yokogawa
following an investigation conducted by Yokogawa.
The purchaser shall bear the responsibility for repair costs, even during the warranty
period, if the malfunction is due to:
Improper and/or inadequate maintenance by the purchaser.
Malfunction or damage due to a failure to handle, use, or store the instrument in accordance with
the design specifications.
Use of the product in question in a location not conforming to the standards specified by
Yokogawa, or due to improper maintenance of the installation location.
Failure or damage due to modification or repair by any party except Yokogawa or an approved
representative of Yokogawa.
Malfunction or damage from improper relocation of the product in question after delivery.
Reason of force majeure such as fires, earthquakes, storms/floods, thunder/lightening, or other
natural disasters, or disturbances, riots, warfare, or radioactive contamination.
2. Notes on Handling
This chapter provides important information on how to handle this product. Read this carefully
before using this product.
This product is fully factory-tested upon shipment. When this product is delivered, check the
appearance for damage.
2.1 Check the Model and Specifications
The model name and specifications are written on the name plate attached to the case. Verify that
the specification indicated in the “Model and Suffix Code” in General Specification “GS
01W03B01-01EN” is in compliance with the specifications written on the order sheet.
2.2 Transport
To prevent damage while in transit, leave this product in the original shipping container until it
reaches the installation site.
2.3 Storage
When an extended storage period is expected, observe the following precautions.
1. Choose a storage location that satisfies the following requirements.
A location that is not exposed to rain or water.
A location subject to a minimum of vibration or impact.
The temperature and humidity limits refer to “5.1 General Specifications”.
2. If at all possible, store this product in factory-shipped condition, that is, in the original shipping
container.
3. Installation
3.1 Precautions
Before installing, refer to the users manual of the device to be connected to this product.
For additional information on the ambient conditions allowed at the installation location, refer to
“5.1 General Specifications”.
3.2 Mounting
The installation procedure is the following.
1. Check the direction of the pin, inserting the connector.
2. Tighten the lock nut to a torque of 1.2 Nm.
Removal is the reverse procedure of the installation.
1
2
Lock nut
IMPORTANT
The connector is covered with a cap at the time of delivery. Keep the cap attached until the
installation of this product to protect the inside connection part.
The unscrewed cap should be stored in order to replace it immediately after this product is
removed.
If there is a possibility that get wet with water, use the protection cap of the optional specification.
CAUTION
Use the dedicated remote antenna cable provided by Yokogawa as accessories for this
product.
The remote antenna cable and other cables should not be bundled together.
CAUTION
To maintain a good connection status between the modules, protect the connector from the
corrosive atmosphere by the following treatment. When winding the tape, do not wound on the
name plate.
1. Clean the connection to be protected.
2. Wind the butyl rubber self-bonding tape around the connection. See the manual of the tape
about the winding.
3. To protect the butyl rubber self-bonding tape from the environment such as ultraviolet rays and
so on, wind vinyl tape (or a vinyl type self-bonding tape) on it.
4. Operation
For the usage of this product, refer to the user ’s manual of the device to be connected to this
product.
5. Specifications
5.1 General Specifications
Communication Protocol:
ISA100.11aIEEE802.15.4
Data Rate:
250 kbps
Frequency:
2400 - 2483.5 MH license free ISM band
Radio Security:
AES 128 bit codified
RF Transmitter Power:
12dBm (Variable)
Antenna:
2 dBi (Omni directional)
Power Supply Voltage:
2.9 - 4.8 V
Consumption Current:
Max. 60 mA
Update Period:
1to 3600 s
Connection Interface:
5-pin round connector dedicated
Wired Communication:
RS485 compliant 9600 bps
Ambient Temperature Limits:
Operating: -40 to +85 (altitude: up to 3000 m) Storage: -40 to +85
Ambient Humidity Limits:
Operating:0 to 100% RH (non-condensation) Storage: 0 to 100% RH (non-condensation)
Temperature Gradient:
Operating: ±10/h or less Storage: ±10/h or less
Vibration Resistance:
0.21mm P-P (10 - 60 Hz), 3G (60 - 2k Hz)
Shock Resistance:
50G 11 ms
Grounding:
Class-D grounding (no sharing ground with others)
Weight:
100 g
5.2 Regulatory Compliance Statements
This device contains the wireless module which satisfies the following standards.
* Please confirm that an installation region fulfills an applicable standard. If additional regulatory
information and approvals are required, contact a Yokogawa representative.
Japanese Radio Law:
Construction Design Attestation Number: 006-000202
R&TTE Conformity Standards:
EN 300 328, EN 301 489-1, EN 301 489-17
We, Yokogawa Electric Corporation hereby declare that this equipment, model FN110 is in
compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The CE declaration of conformity for R&TTE for this product can be found at
http://www.yokogawa.com/fld/
Users
Manual
FN SERIES

Summary of content (2 pages)