;our One Shop For Complete High-Speed Wireless Internet Systems!!! Model AMP2440 MODEL AMP2440 POLE MOUNTED BI-DIRECTIONAL REMOTE BI-DIRECTIONAL POWER POWER AMPLIFIERS FOR 2.4 GHz AMPLIFIERS FOR 2.4 GHz w w w.ydi.com Installationand and Installation Operation OperationManual Manual or Contact Our Sales Department Toll Free at: 888-297 -9090 or call 703-237 -9090 Ver 2.3 Version 2.0 Jan 2001 May 2000 Young Design Inc 146B Hillwood Ave.
Limited Warranty Young Design, Inc. (YDI) warrants that your device is free of defects in material and workmanship for a period of one year after initial purchase. YDI will, in this period of time, repair or replace, any YDI product returned to the factory, freight prepaid. The YDI warranty covers repairs or replacement (at YDI’s option) of the product only. YDI is not responsible for the cost of removal, reinstallation, or shipping to the place of repair.
NOTES: TABLE OF CONTENTS 1. DESCRIPTION............................................................................................................1 2. AMPLIFIER FEATURES............................................................................................1 2.1 GENERAL SPECIFICATIONS...............................................................................2 3. AMPLIFIER KIT..........................................................................................................3 4.
1. Description The AMP2440 is a bi-directional amplifier designed for extending the range of 2.4 GHz wireless radio modems, Wireless LAN cards, Access Points and wireless bridges. The units provide transmit power amplification as well as receive signal gain. The amplifier is installed right at the antenna’s feed point, providing maximum effectiveness of transmit power. This has the effect of compensating for signal loss in the transmitter cable to the antenna.
NOTES: 2.1 General Specifications Receiver Low Noise Amplifier (LNA) Operating Range: 2400-2483 MHz Receive Gain: Operating Mode: Bi-directional, half-duplex. Senses RF carrier from transmitter and automatically switches from receive to transmit mode.
3. Amplifier Kit IMPORTANT: Only mount the amplifier with the connectors facing downward. Do not mount it with the connectors facing sideways or upwards. Each Amplifier Kit Includes: • • • • Bi-directional remote mounted amplifier DC Power Injector 12 VDC, 110/220 VAC Power Supply Stainless Steel U-Bolts and mounting bracket for amp • Installation Manual NOTE: 1. MPE distance figures are based on a conservative “worst case” prediction, i.e.
Safety Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment when installed as directed. This equipment should be installed and operated with fix-mounted antennas that are installed such that the main lobe(s) of these antennas will have a minimum of 2 meters of separation distance between the antenna and all persons’ body during normal operation.
5. Amplifier Connections and Indicators CAUTION: Only use high quality N-type connectors. Do not use PL259 “CB” type UHF connectors. Doing so will ruin the N-Female jacks and void your warranty. Transmit LED: Receive LED: DC Injector Connection: Antenna Connection: This LED glows RED when the amp has switched to the transmit mode. This occurs when the amp detects RF power at the jack labeled “To DC Injector”.
Table A - Conversions from dBm to Watts dBm 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 dBm 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 60 Watts 1.0 mW 1.3 mW 1.6 mW 2.0 mW 2.5 mW 3.2 mW 4.0 mW 5.0 mW 6 mW 8 mW 10 mW 13 mW 16 mW 20 mW 25 mW 32 mW 40 mW 50 mW 64 mW 80 mW 100 mW 128 mW 160 mW 200 mW 250 mW 320 mW Watts 400 mW 500 mW 640 mW 800 mW 1.0 W 1.3 W 1.6 W 2.0 W 2.5 W 3.0 W 4.0 W 5.0 W 6.0 W 8.
Page 7 C o nn ec tor re qu ired b y ra dio N -fe m a le N -fe m a le To e na ble the D C p o w e r sup p ly to po w e r bo th th e D C Injector a nd th e ra dio, th e a m p kit sho u ld b e o rd e re d w ith th e D U A L-D C op tion a lo ng w ith th e a pp ro pria te D C Ju m pe r cab le. To Netw ork R adio M odem , A cc es s Point, W LA N C ard, etc DC PO W E R INJEC TO R RF + DC 12 VD C B a rrel P lug 12 VDC S hort le n gth o f R G 58 /U O ption a l J u m pe r C a ble (C A B -D C -2.
Page 7 C o nn ec tor re qu ired b y ra dio N -fe m a le N -fe m a le To e na ble the D C p o w e r sup p ly to po w e r bo th th e D C Injector a nd th e ra dio, th e a m p kit sho u ld b e o rd e re d w ith th e D U A L-D C op tion a lo ng w ith th e a pp ro pria te D C Ju m pe r cab le. To Netw ork R adio M odem , A cc es s Point, W LA N C ard, etc DC PO W E R INJEC TO R RF + DC 12 VD C B a rrel P lug 12 VDC S hort le n gth o f R G 58 /U O ption a l J u m pe r C a ble (C A B -D C -2.
Table A - Conversions from dBm to Watts dBm 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 dBm 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 60 Watts 1.0 mW 1.3 mW 1.6 mW 2.0 mW 2.5 mW 3.2 mW 4.0 mW 5.0 mW 6 mW 8 mW 10 mW 13 mW 16 mW 20 mW 25 mW 32 mW 40 mW 50 mW 64 mW 80 mW 100 mW 128 mW 160 mW 200 mW 250 mW 320 mW Watts 400 mW 500 mW 640 mW 800 mW 1.0 W 1.3 W 1.6 W 2.0 W 2.5 W 3.0 W 4.0 W 5.0 W 6.0 W 8.
5. Amplifier Connections and Indicators CAUTION: Only use high quality N-type connectors. Do not use PL259 “CB” type UHF connectors. Doing so will ruin the N-Female jacks and void your warranty. Transmit LED: Receive LED: DC Injector Connection: Antenna Connection: This LED glows RED when the amp has switched to the transmit mode. This occurs when the amp detects RF power at the jack labeled “To DC Injector”.
Safety Notice This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment when installed as directed. This equipment should be installed and operated with fix-mounted antennas that are installed such that the main lobe(s) of these antennas will have a minimum of 2 meters of separation distance between the antenna and all persons’ body during normal operation.
3. Amplifier Kit IMPORTANT: Only mount the amplifier with the connectors facing downward. Do not mount it with the connectors facing sideways or upwards.
NOTE: 1. MPE distance figures are based on a conservative “worst case” prediction, i.e. +24 dBm into antenna using formula S=EIRP/(4piR2) and no calculaton for duty factor. In practice the minimum distance will be much shorter. 2. The minimum MPE distance has been calculated for the maximum allowed Power Density (S) limit os 1.0 mW/cm2 in the Frequency range 1500 - 100,000 MHz for uncontrolled environments (Ref. 2).
Limited Warranty Young Design, Inc. (YDI) warrants that your device is free of defects in material and workmanship for a period of one year after initial purchase. YDI will, in this period of time, repair or replace, any YDI product returned to the factory, freight prepaid. The YDI warranty covers repairs or replacement (at YDI’s option) of the product only. YDI is not responsible for the cost of removal, reinstallation, or shipping to the place of repair.