V3.1 Supplementary Manual This supplementary manual explains mainly the functions that have been added or changed in QL5/QL1 firmware V3.1. Use it in conjunction with the QL5/QL1 V3 Owner's Manual and Reference Manual.
Contents Contents Input channels .......................................................................... 3 Added pan function (Monaural input channels only) ............................................... 3 Changing input signal processing when setting LR-MONO (Stereo input channels only) ......................................................................... 4 I/O Devices window .................................................................. 5 Added supported devices .............................
Input channels Input channels Added pan function (Monaural input channels only) The pan setting for signals sent to the STEREO bus enables you to select PAN LAW settings. You can select one of the following: CENTER NOMINAL The pan level is nominal at center and +3dB when panned 100% either left or right. LR NOMINAL The pan level is -3dB at center and nominal when panned 100% either left or right. NOTE The settings are also applied to the signals sent to the stereo MIX buses. STEP 1.
Input channels Changing input signal processing when setting LRMONO (Stereo input channels only) You can also check the status of PAN LAW settings in the window shown below. For channels where the mark is on, PAN LAW is set to LR NOMINAL. • TO STEREO/MONO window (CH1–32, CH33–64/ST IN (QL5), ST IN (QL1)) In order to ensure the appropriate level, the signal processing regarding the LR-MONO setting has been changed as follows.
I/O Devices window 3 SLOT 1 - 4 LOCK indicators I/O Devices window This indicates the word clock status for slots 1 to 4. If the word clock is operating normally, this indicator will be green. Added supported devices Off The RSio64-D is now supported. You can operate the RSio64-D in the I/O Devices window. Green (On) LOCK I/O Devices window (I/O page) Q RSio64-D display 1 2 3 45 B There is no card in the slot. Or, an unsupported card is in the slot.
I/O Devices window 8 USER PATTERN button • WORD CLOCK SLOT1 1/2 indicator • WORD CLOCK DANTE indicator Indicates the word clock source status for the RSio64-D. Press this button to open the window for setting the audio routing user pattern in the RSio64-D. Patch to the desired output ports of the slots and Dante. NOTE WCLK IN On when using the word clock signal being input from the WORD CLOCK IN connector on the rear panel of the RSio64-D. Flashes*1 if there is no valid word clock input.
I/O Devices window Added third-party equipment’s HA control function NOTE The indicator on the right side of the rack indicates the control status of the device. It is now possible to control supported third-party equipment’s head amps (HA) from the console. You can control HA by registering supported devices in the DANTE SETUP window. Searching for device to be controlled NOTE While in PREVIEW mode, changes made to HA parameters from the console are not applied to the device.
Setup window Setup window • DCA 1 - 8 cue • DCA 1 - 8 DCA MUTE TARGET (DCA group mute targets) NOTE Even if the cue mode is LAST CUE, the cue for the target DCA will come on at the same time for consoles linked by cascade connections. Added functions for cascade connections The number of operations that can be linked when making cascade connections between QL series consoles has been increased. You can now select multiple operations. An attenuator is now built into the CASCADE input signal.
Setup window CASCADE window (CASCADE IN ATT page) 1 1 ATT knobs Display the attenuator values (-96.0dB to 0.0dB) for cascade input signals. You can adjust these values using multifunction knobs 1 - 8 in the Centralogic section or the [TOUCH AND TURN] knob. NOTE You can use these knobs as SUB IN with adjustable input level. Doing so allows you to sum the signals from other consoles to a bus, without using up inputs and buses. 9 V3.
Channel job Channel job GLOBAL RECALL SAFE window The following parameters have been added. CASCADE IN Added parameters to Recall Safe function CASCADE OUT Parameters that can be excluded from recall operations have been added. CASCADE IN PATCH and CASCADE IN ATT settings CASCADE OUT PATCH settings RECALL SAFE MODE window CASCADE IN and CASCADE OUT have been added to the GLOBAL RECALL SAFE field. 10 V3.
Scene memory Scene memory Added parameters to Focus Recall function Parameters that can be set in the Focus Recall operations have been added. Additional parameters are the same as those in the Recall Safe function. Added parameters to Global Paste function CASCADE IN and CASCADE OUT have been added as parameters that can be selected for the Global Paste function. GLOBAL PASTE window (PATCH/OTHERs page) The following parameters have been added.
SAVE/LOAD window SAVE/LOAD window Added remount function to USB flash drives If USB flash drive is not mounted, the FORMAT button will become a USB REMOUNT button. Press this button to mount a USB flash drive. Use this button if a USB flash drive is not recognized after it has been removed and reinserted. 12 V3.
Other functions Other functions Added update function to Dante firmware You can now update the firmware for the Dante module in the QL console from a USB flash drive, without using Dante Firmware Update Manager. If the following window is displayed, the console has entered the mode for updating the Dante module firmware. For details about this operation, refer to the “QL5/QL1 Firmware Update Guide”. Do not power-off the console while the update is proceeding. To exit this mode, press the CANCEL button.
Yamaha Pro Audio Global Web Site http://www.yamahaproaudio.com/ Yamaha Manual Library http://www.yamaha.co.