Yale Real Living™ Key Free Touchscreen Deadbolt Installation and Programming Instructions x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination screws x2 M6x47mm Long through bolt 1 P/N AYRD-120-STANDALONE-INST-FUL Rev B
Preparing Door 2 P/N AYRD-120-STANDALONE-INST-FUL Rev B
1 Installing Latch & Strike Plate 2-3/8" position defaut x4 2-3/4" position O optional Pull Press Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
2 Installing Touchscreen Escutcheon Inside of Door Outside of Door ! Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
3 Installing Interior Mounting Plate Loosen screw to remove cover.
4 Attaching the Cable Assembly 6 P/N AYRD-120-STANDALONE-INST-FUL Rev B
5 Installing Interior Escutcheon x3 7 P/N AYRD-120-STANDALONE-INST-FUL Rev B
Testing Operation ! Bolt must be in retracted (unlocked) position before installing AA batteries.
Handing the Lock Press . Enter new Master PIN code (4-8 digits). Press to complete. After entering the Master PIN code, press any key to complete handing.
6 Installing Cover Congratulations, you've installed the Yale Real Living™ Key Free Touchscreen Deadbolt T1L! Turn sheet over for Programming Instructions to customize your product.
Programming Instructions Lock-out ModeTouchscreen Flashes Low Battery Warning Flashes RED Failsafe 9 volt Battery Connection (Use Alkaline battery) Master PIN Code must be created before any further programming. Max User Codes = 25 Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user's authority to operate the equipment.
1 Creating Master PIN Code Press Enter 4-8 digit Master PIN Code.
2 Creating User PIN Codes Master PIN code must be created first. *Max User Codes = 25 Enter Master PIN code Press Press Press Press Enter User number to be created (1-25)*.
3 Unlocking Door with PIN Code Enter PIN Press "Unlock" Code Chart Duplicate if necessary PIN Code Management (Up to 25 Users) User Type User Name User # Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ 14 P/N AYRD-120-STANDALONE-INST-FUL Rev B PIN Code
Resetting Lock to Factory Default When lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see "Factory Default Settings"). 1. Remove the battery cover. 2. Remove the batteries. 3. While pressing the reset button (minimum of 3 seconds) reinstall batteries. Release reset button. 4. Replace battery cover.
Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the touchscreen flashes 8 times and the lock beeps 3 times as well. Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone play-back for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code.
Feature Programming Through Menu Mode Using Master PIN code* key. 1. Enter the 4-8 digit Master PIN code followed by the 2. Enter digit corresponding to the function to be performed followed by the key. *The Master PIN code must be registered prior to any other programming of the lock. 1 M 2 User Number (UN) 1~25 M Master PIN Code Setting Register User PIN Code Registration U Delete Advanced Lock Settings Automatic Re-lock Enable Disable One Touch Locking Default settings in bold.
Programming Troubleshooting Symptom • • Lock does not respond – door is open and accessible. • • Suggested Action Press each touchscreen key for response when pressed. Check batteries are installed and oriented correctly (polarity) in the battery case. Check batteries are in good condition; replace batteries if discharged. Check to see if cable is fully connected and not pinched. Lock does not respond – door is locked and inaccessible. • Batteries may be completely discharged.
FCC: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Yale Real Living™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2014, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc.