Yale Assure Lock SL Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD256/YRD456) ® ® ™ Optional Network Module Before you begin x4 x3 #7 wood & #8-32 #8-32 x 5/16" machine x 20mm Machine screws Combination screws DOWNLOAD THE BILT APP for step-by-step installation instructions & to register your product x2 M6x36mm PPHMS (2-1/4" ) OR x2 M6x44mm PPHMS (1-3/4-2" ) FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY 1 P/N
Preparing Door ! Refer to template for correct door prep 2 P/N YRL-SLKFTSINSTL-FUL Rev A
1 Installing Latch & Strike Plate 2-3/8" position defaut x4 2-3/4" position O optional Pull Press Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
2 Installing Touchscreen Escutcheon Inside of Door Outside of Door ! Bolt must be in retracted (unlocked) position. Note horizontal orientation of mechanism.
3 Installing Interior Mounting Plate Loosen screw to remove cover. x2 ! Choose through bolt appropriate for your door thickness.
4 Attaching the Cable Assembly 6 P/N YRL-SLKFTSINSTL-FUL Rev A
5 Installing Interior Escutcheon x3 7 P/N YRL-SLKFTSINSTL-FUL Rev A
Testing Operation 3 ! Bolt must be in retracted (unlocked) position before installing batteries.
6 Installing Batteries/Handing the Lock "Welcome to Yale Real Living." Lock automatically adjusts for proper handing. 7 Installing Optional Network Module ! Batteries must be removed prior to removing and/or inserting network module.
8 Installing Cover Tighten screw to replace cover. Congratulations, you've installed the Yale® Assure Lock™ SL Key Free Touchscreen Deadbolt (YRD256/YRD456)! Continue to Programming Instructions to customize your product.
Programming Instructions Exterior Escutcheon "P" Key (Return to Previous) Speaker Interior Escutcheon Low Battery Indicator Lockout Mode Failsafe 9 volt Battery Connection (Use Alkaline battery) Privacy Mode Button Lock Activation OR Master PIN Code must be created before any further programming. Max User Codes = 250 with Network Module. Max User Codes = 25 without.
1 Creating Master PIN Code Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed. "Register Master Code. Press the gear key to continue." Press "Enter a 4 to 8 digit PIN code followed by the gear key." Enter 4-8 digit Master PIN Code. "Registered.
2 Creating User PIN Codes Master PIN code must be created first. *Max user codes = 250 with Network Module. Max user codes = 25 without. Enter Master PIN code "Menu Mode, enter number, press the gear key to continue.
3 Unlocking Door with PIN Code Enter PIN Code Press Code Chart Duplicate if necessary PIN Code Management (With Network Module - Up to 250 Users) User Type User Name User # Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ 14 P/N YRL-SLKFTSINSTL-FUL Rev A PIN Code
Resetting Lock to Factory Default When lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see below). Reset Button 1. Remove the battery cover and batteries. 2. Remove the interior escutcheon to access the reset button. 3. The reset button (see image at right) is located beside the PCB cable connector. 4. While pressing the reset button (minimum of 3 seconds) reinstall batteries.
Definitions All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the RED locked padlock will appear on the screen. Automatic Re-lock Time: After a successful code entry and the unit unlocks, it will automatically re-lock after thirty (30) seconds. Inside Indicator Light: Located on the interior escutcheon.
Feature Programming Through Menu Mode Using Master PIN code* 1. Touch screen with back of hand or palm to activate. 2. Enter 4-8 digit master PIN code* followed by key. Lock Response: "Menu mode, enter number, press key to continue." 3. Enter digit corresponding to the function to be performed followed by the key. Follow the voice commands. *The Master PIN code must be registered prior to any other programming of the lock.
Programming Troubleshooting Symptom • Lock does not respond – door is open and accessible. • • • • Lock does not respond – door is locked and inaccessible. Unit is on for a while then shows no reaction. Lights dim. Unit chimes to indicate code acceptance, but the door will not open. Unit operates to allow access, but will not automatically re-lock. PIN codes will not register. Upon entering a PIN code and pressing key, the unit displays " invalid code" error or lock times out without responding.
Hardware Troubleshooting Cycle lock in both the locked and unlocked positions. If problems are found: Door is binding a. Check that door and frame are properly aligned and door is free swinging. b. Check hinges: They should not be loose or have excessive wear on knuckles. Bolt will not deadlock a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing the depth of the pocket for the bolt. b.
FCC: Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.