FCC ID: K6610583021/IC ID: 511B-10583021 VX-P820/-P870 SERIES OPERATING MANUAL VERTEX STANDARD CO., LTD. 4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan VERTEX STANDARD US Headquarters 10900 Walker Street, Cypress, CA 90630, U.S.A. YAESU EUROPE B.V. P.O. Box 75525, 1118 ZN Schiphol, The Netherlands 1 2 3 A 4 5 6 B 7 8 9 C 0 A B C YAESU UK LTD. D Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K. D 16-Key Version VERTEX STANDARD HK LTD.
FCC ID: K6610583021/IC ID: 511B-10583021 CONTENTS Note ................................................................................. 1 Warning! FCC RF Exposure Requirements ................ 2 Controls & Connectors (16-Key Version) .................... 4 Controls & Connectors (4-Key Version) ...................... 5 Controls & Connectors (Non-LCD Version) ............... 6 LCD Icons & Indicators (16- & 4-Key Versions) ........ 7 Before You Begin ..........................................................
FCC ID: K6610583021/IC ID: 511B-10583021 NOTE In order to maintain the specified water integrity performance, periodic maintenance is recommended. Should the radio sustain a severe shock (e.g. if it is dropped), the water integrity may be compromised, requiring service. Should this occur, contact your Authorized Vertex Dealer or Vertex Standard USA, Inc. Important Notice for North American Users Regarding 406 MHz Guard Band The U.S.
FCC ID: K6610583021/IC ID: 511B-10583021 WARNING! FCC RF EXPOSURE REQUIREMENTS This Radio has been tested and complies with the Federal Communications Commission (FCC) RF exposure limits for Occupational Use/Controlled exposure environment. In addition, it complies with the following Standards and Guidelines: FCC 96-326, Guidelines for Evaluating the Environmental Effects of Radio-Frequency Radiation.
FCC ID: K6610583021/IC ID: 511B-10583021 WARNING! RF EXPOSURE REQUIREMENTS The radio must be used with a maximum operating duty cycle not exceeding 50%, in typical Push-toTalk configurations. DO NOT transmit for more than 50% of total radio use time (50% duty cycle). Transmitting more than 50% of the time can cause FCC RF exposure compliance requirements to be exceeded. The radio is transmitting when the red LED on the top of the radio is illuminated.
FCC ID: K6610583021/IC ID: 511B-10583021 CONTROLS & CONNECTORS (16-KEY VERSION) VOL/PWR Knob LED Indicator Steady Red: Transmitting in progress Blinking Green: Busy Channel Steady Green: Tone Squelch in defeated condition Dealer Programmed Color : Emergency, 5-Tone Decoded, or 2-Tone Decoded CH (Channel) Selector Antenna Jack TOP SEL Key Speaker Microphone : one of “Flashing in white,” “Continuation changes in sequential colors,” or “toggling the two colors.
FCC ID: K6610583021/IC ID: 511B-10583021 CONTROLS & CONNECTORS (4-KEY VERSION) VOL/PWR Knob LED Indicator Steady Red: Transmitting in progress Blinking Green: Busy Channel Steady Green: Tone Squelch in defeated condition Dealer Programmed Color : Emergency, 5-Tone Decoded, or 2-Tone Decoded CH (Channel) Selector Antenna Jack TOP SEL Key Speaker Microphone : one of “Flashing in white,” “Continuation changes in sequential colors,” or “toggling the two colors.
FCC ID: K6610583021/IC ID: 511B-10583021 CONTROLS & CONNECTORS (NON-LCD VERSION) VOL/PWR Knob LED Indicator Steady Red: Transmitting in progress Blinking Green: Busy Channel Steady Green: Tone Squelch in defeated condition Dealer Programmed Color : Emergency, 5-Tone Decoded, or 2-Tone Decoded CH (Channel) Selector Antenna Jack TOP SEL Key Speaker Microphone : one of “Flashing in white,” “Continuation changes in sequential colors,” or “toggling the two colors.
FCC ID: K6610583021/IC ID: 511B-10583021 LCD ICONS & INDICATORS (16-KEY & 4-KEY VERSIONS) “CALL” Indicator This channel on “SCAN” List Priority Scan is activated Receiver Monitor “Talk-Around” is enabled Battery Indicator “DUAL WATCH” is activated Low Transmit Power Mode On SUB-LCD 888: Channel Group Number -P-: Priority Channel -H-: Home Channel In: ARTS “In Range” Out: ARTS “Out of Range” “Analog Transmission” is activated RSSI Indicator (four steps) “Group Scan” is enabled Encryption is activated
FCC ID: K6610583021/IC ID: 511B-10583021 BEFORE YOU BEGIN Battery Pack Installation and Removal To install the battery, hold the transceiver with your left hand, so your palm is over the speaker and your thumb is on the top of the belt clip. Carefully mate the battery’s four insertion slots with their corresponding alignment tabs on the transceiver case, while tilting the Belt Clip outward. Proper alignment occurs with the battery pack offset about 1/2 inch from the top edge of the battery compartment.
FCC ID: K6610583021/IC ID: 511B-10583021 BEFORE YOU BEGIN Battery Charging Insert the DC plug from the PA-39 AC Adapter into the DC jack on the bottom side of the VAC920 Desktop Rapid Charger, then plug the PA39 AC Adapter into the AC line outlet. Insert the battery pack into the VAC-920 Desktop Rapid Charger while aligning the slots of the battery pack with the guides in the nest of the VAC-920; refer to the illustration at the right for details on proper positioning of the pack.
FCC ID: K6610583021/IC ID: 511B-10583021 OPERATION Preliminary Steps Install a charged battery pack onto the transceiver, as described previously. Screw the supplied antenna onto the Antenna jack. Never attempt to operate this transceiver without an antenna connected. If you have a Speaker/Microphone, we recommend that it not be connected until you are familiar with the basic operation of the VX-P820/-P870. 10 Operation Quick Start Turn the top panel’s VOL/PWR knob clockwise to turn the radio on.
FCC ID: K6610583021/IC ID: 511B-10583021 OPERATION Rotate the VOL/PWR knob to set the volume level. If no signal is present, press and hold in the MONITOR button (under the PTT switch) more than 2 seconds; background noise will now be heard, and you may use this to set the VOL/PWR knob for the desired audio level. Press and hold the MONITOR button more than 2 seconds (or press the MONITOR button twice) to quiet the noise and resume normal (quiet) monitoring.
FCC ID: K6610583021/IC ID: 511B-10583021 OPERATION 2) When you press the PTT switch on the Speaker/Microphone, it disables the internal microphone, and vice versa. Do not remove/install the Speaker/Microphone in a hazardous location. If the Busy Channel Lockout feature has been programmed on a channel, the radio will not transmit when a carrier is present. Instead, the radio will generate short beep three times and indicate “* ERROR *” on the display (16-key and 4-key versions).
FCC ID: K6610583021/IC ID: 511B-10583021 NOTE VX-P820/-P870 SERIES OPERATING MANUAL 13 Vertex Standard Co., Ltd.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION For future reference, check the box next to each function that has been assigned to the Programmable key on your particular radio, and keep it handy. Programmable Key Functions All versions of the VX-P820/-P870 include the TOP SEL, SIDE SEL, MONITOR, and LAMP keys, and the TOGGLE switch. The 16-key and 4-key versions include the [A], [B], [C], and [D] function keys. Furthermore, the 16-key version includes the [ ] and [#] function keys.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION FUNCTION TOP SEL MONITOR LAMP [A ] PROGRAMMABLE KEY [B ] [C ] [ D] [ ] [# ] Follow-Me Dual Watch Group Up Group Down Channel Up Channel Down Set Call/Reset Call 1 Call 2 Call 3 Call 4 Call 5 Code Up Code Down Code Set Speed Dial Emergency Home Selectable Tone Direct Channel #1 Direct Channel #2 Direct Channel #3 Direct Channel #4 SQL AF Min Volume Audio PC (PIT) Lone Worker TA Scan Individual Call TX Mode VX-P820/-P870 SERIES OPERATING M
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION Description of Operating Functions MONITOR Press the assigned programmable key to cancel CTCSS- and DCS-controlled squelch; the BUSY/ TX indicator will glow green. Press and hold this button for 1.5 seconds to hear background noise (unmute the audio); the BUSY/TX indicator will blink green. LAMP Press the assigned programmable key to illuminate the LCD for five seconds.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION DUAL WATCH TALK AROUND (TA) The Dual Watch feature is similar to the SCAN feature, except that only two channels are monitored: The current operating channel; and The Priority channel. Press the assigned programmable key to activate the Talk Around feature when you are operating on duplex channel systems (separate receive and transmit frequencies, utilizing a “repeater” station).
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION TX SAVE DISABLE FOLLOW-ME SCAN Press the assigned programmable key to disable the Transmit Battery Saver, if you are operating in a location where high power is almost always needed. The “Follow-Me” Scan feature checks a User-assigned Priority Channel regularly as you scan other channels.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION FOLLOW-ME DUAL WATCH GROUP UP/DOWN To set up a “Dual Watch” frequency pair using the “Follow-Me” feature, select a channel using the CH Selector knob. Now press the assigned programmable key; pressing the assigned programmable key locks the current channel as the User-assigned Priority Channel. Now rotate the CH Selector knob to select another channel (not the “Scanning Start” channel).
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION “-SCAN Stop-” will appear on the LCD for one second after pressing the assigned programmable key. CHANNEL UP/DOWN Press the assigned programmable key to send a 2tone/5-tone sequential tone group which is pre-defined. Press the assigned programmable key to select a different channel within the current group. CODE UP/DOWN SET Press the assigned programmable key to activate the “User Set” (Menu) Mode.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION EMERGENCY SQL The VX-P820/-P870 series include an “Emergency” feature which may be useful for alerting another party monitoring on the same frequency as your transceiver’s channel. You can manually adjust the squelch level using this function: Press the assigned programmable key. A tone will sound, and the current squelch level will appear on the display. Press the MONITOR/LAMP button to select the desired squelch level.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION DTMF CODE SET (16-KEY VERSION ONLY) INDIVIDUAL CALL (16-KEY VERSION ONLY) You may send the desired telephone number manually. Press the assigned programmable key to enable the Individual Calling on the APCO Project 25 Digital System. To dial a number manually, press the assigned programmable key, then press the desired numbers on the front panel’s numeric key. Now, press the PTT switch to send the telephone number.
FCC ID: K6610583021/IC ID: 511B-10583021 ADVANCED OPERATION TX Mode Press the assigned programmable key to select the TX mode. Available selections are: TX Mixed: The VX-P820/-P870 transmits in the Analog Mode, when after receiving the analog signal. Meanwhile, the VX-P820/-P870 transmits in the Digital Mode, when after receiving the digital signal. TX Digital: The VX-P820/-P870 transmits in the Digital Mode. TX Analog: The VX-P820/-P870 transmits in the Analog Mode.
FCC ID: K6610583021/IC ID: 511B-10583021 RSSI BEEP LOCK This feature allows you to inform the Receiving Signal Level while operating on the APCO Project 25 Digital System. In order to prevent accidental channel change or inadvertent transmission, various aspects of the VX-P820/-P870’s knob, soft keys, and PTT switch may be locked. The precise lockout configulation is programmed by your Dealer. When the Receiving Signal Level is weaken, the alert will sound every one second.
FCC ID: K6610583021/IC ID: 511B-10583021 USER SET MODE The VX-P820/-P870 Series includes a “User Set (Menu)” Mode which allows the user to define or configure various settings, such as Beep On/Off, Squelch, LCD contrast, etc. To activate the “User Set (Menu)” Mode: Press the assigned programmable key for the “SET” function to enter the “User Set Mode.” Select the User Set Mode Item you want change using the CH selector knob. Press the MONITOR/LAMP button to select the status of the selected item.
FCC ID: K6610583021/IC ID: 511B-10583021 OPTIONAL ACCESSORIES 26 FNB-V86LI FNB-V87LI FNB-V92LIIS FBA-34 VAC-920 PA-39 MH-50D7A MH-65B7A MH-66A7A MH-66B7A CLIP-820 ATV-8A ATV-8B ATV-8C ATV-6XL 7.4V, 1150 mAh Lithium-Ion Battery 7.4V, 2000 mAh Lithium-Ion Battery 7.
FCC ID: K6610583021/IC ID: 511B-10583021 NOTE VX-P820/-P870 SERIES OPERATING MANUAL 27 Vertex Standard Co., Ltd.
FCC ID: K6610583021/IC ID: 511B-10583021 NOTE 28 VX-P820/-P870 SERIES OPERATING MANUAL Vertex Standard Co., Ltd.
FCC ID: K6610583021/IC ID: 511B-10583021 Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the user’s authorization to operate this device. Vertex Standard Co., Ltd.
FCC ID: K6610583021/IC ID: 511B-10583021 Copyright 2006 VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual may be reproduced without the permission of VERTEX STANDARD CO., LTD. Printed in Japan E C 0 5 8 N 2 6 0 Vertex Standard Co., Ltd.