PTR 5610-S Bluetooth Low Energy Module Specification V1.1 Shenzhen Lanke Xuntong Technology Co., Ltd WWW.abluetech.com VERSION V1.0 V1.1 V1.2 COPYRIGHT ©2019 ALL RIGHTS RESERVED DATE 2019-4-15 2019-7-16 2019-12-20 Xun Tong Tech RELEASE NOTE First release update Modify pin assignment TEL: + 86 75526675941 E-mail: nrf@freqchina.
Index 1. Overview......................................................................................................................................... 1.1. Product introduction............................................................................................................ 1.2. Feature................................................................................................................................. √ Support Bluetooth 5.0 protocol, high-speed transmission.......................
.3. Common Command............................................................................................................. 3.3.1. Switch mode enable.................................................................................................. 3.3.2. Switch Transmission Mode to Command Line Mode.............................................. 3.3.3. Switch Command Line Mode to Transmission Mode.............................................. 3.4. Extended function command...............................
1. Overview 1.1. Product introduction PTR5610-S is a BLE module with a slave feature. The module is based on nRF52810 with an ARM Cortex-M4F processor from Nordic Semiconductor.Therefore the PTR5610-S features Bluetooth 5.0,high performance and ultra low power(ULP). The user's MCU is connected to the module through a serial port (UART), so that it enables bidirectional communication of data with the mobile device.
4. Most of “AT Commands” take effect immediately while some of them take effect after the module has been reset. 5. The “AT Command” setting is valid in the current running cycle. If the setting needs to be saved, it can be achieved by software reset . 6. In an environment where the amount of data is very large or the signal is not good, the original data cannot be sent to the peer device in time, which will cause the serial port buffer overflow problem.
Figure 2 Package diagram 2.2. Pin assignment The module pin assignments are shown in Figure 3 (TOP VIEW). Please see the PTR5610 module data sheet for details. Figure 2 Pin Distribution 2.3. Pin definition Serial num Abbreviation 1 WAKE Input/outp ut I COPYRIGHT ©2019 ALL RIGHTS RESERVED Explanation Rising edge: This pin is used as a wake-up function if the module enters deep sleep mode or low power advertise Xun Tong Tech TEL: + 86 75526675941 E-mail: nrf@freqchina.
mode. 2 3 4 5 TX RX SWDIO SWCLK O I / / 6 DON O 7 GPIO3 I/O 8 RESET I 9 10 GND VCC / / 11 STATE O 12 GPIO0 I/O 13 DIN O 14 15 GPIO1 GPIO2 I/O I/O TX pin of the serial port. RX pin of the serial port. / / Indicative signal of data output. Low level: No data is sent by the module . The signal is pulled down to low level after the data sending is complete.
3. AT Command 3.1. Basic function 3.1.1. Baud rate Command AT+BAUD=[Index] AT+BAUD=? ACK Instruction OK+BAUD [Index] 0:9600 (bps) 1:19200 (bps) 2:38400 (bps) 3:57600 (bps) 4:115200 (bps) 5:512000 (bps) 6:1000000 (bps) [Instance] Send:AT+BAUD=0 Return:OK+BAUD OK+BAUD=[Index] [Index]ditto [Instance] Send:AT+BAUD=? Return:OK+BAUD=0 Description:Set or check the baud rate of the module’s uart port.The default setting is 115200bps,8 data bit,1 stop bit,none parity.
AT+TXPW=? OK+TXPW=[Index] [Index]:ditto [Instance] Send:AT+TXPW=? Return:OK+TXPW=0 Description:Set or check the module’s transmit power.The default setting is 0 dbm. *The command takes effect immediately,and be saved after AT+RESET command is used. 3.1.3.
Return:OK+RATE=0 Description:Set or check the module’s transmission speed.The default setting is low speed. *Command takes effect immediately in the non-connected state, and the configure is saved after AT+RESET command is used. *In connected state,command takes effect after disconnected,and the configure is saved automatically. 3.1.5.
3.1.7. Factory default setting Command AT+FADR ACK Instruction OK+FADR [Instance] Send:AT+FADR Return:OK+FADR Description:The module will restart after 150ms,and recover all configuration to the default setting. *The command takes effect immediately. 3.1.8. Software reset Command AT+RESET ACK Instruction OK+RESET [Instance] Send:AT+RESET Return:OK+RESET Description:The module will reset and restart after 150ms,and retain all configuration. *The command takes effect immediately. 3.1.9.
AT+NAME=? OK+NAME=[Param] [Param]ditto [Instance] Send:AT+NAME=? Return:OK+NAME=XUNTONG Description:Set or check the advertise name,the length of the name is up to 29 bytes,the excess will be discarded.The default name is “XT_”+ “6-bytes MAC address of the Bluetooth chip” Notice: The advertise name can only be constituted by numbers, characters, or underscores. *Command takes effect immediately in the non-connected state, and the configure is saved after AT+RESET command is used.
AT+ADST=[Index] AT+ADST=? OK+ADST [Index] 0: stop advertising 1: start connectable advertisement 2: start non-connect advertisement 3: start low-power connectable advertisement 4: start low-power non-connect advertisement [Instance] Send:AT+ADST=0 Return:OK+ADST OK+ADST=[Index] [Index]ditto [Instance] Send:AT+ADST=? Return:OK+ADST=0 Description:Set or check the advertisement type,the default setting is connectable advertisement.
3.2.5.
3.2.7.
used for sending data to mobile device.) *The command takes effect and be saved after AT+RESET command is used. 3.2.9.
Return:OK+STRD=0 Description:If enable, the mode of the module can be switched between Transmission Mode and Command Line Mode.The default setting is “disable”. *The command takes effect and be saved after AT+RESET command is used. 3.3.2. Switch Transmission Mode to Command Line Mode Command ACK Instruction [Instance] When recent mode AT++++ OK+CMD is Transmission Mode Send:AT++++ Return:OK+CMD Description:Switch the working mode from Transmission Mode Command Line Mode.
Return:OK+EYPT AT+EYPT=? OK+EYPT=[Index-1,Index-2] [Index-1]ditto [Index-2]ditto [Instance] Send:AT+EYPT=? Return:OK+EYPT=0,0 Description:Set or check the encryption function,the default setting is “AT+EYPT=0,0”. Information encryption:For encryption of the information over the air. Passkey:If the peer do not transfer a right passkey,the link will be disconnected automatically. *The command takes effect immediately. 3.4.2.
[Instance] Send:AT+GPIOO=? Return: OK+GPIOO=0,0 .......Maximum: 4 Description:Set or check output state of GPIO,the default setting is “disable” . *The command takes effect immediately,and be saved after AT+RESET command is used. 3.4.4. GPIO input setting Command AT+GPIOI=[N, Effective,Data] AT+GPIOI=? ACK Instruction OK+GPIOI [N] The number of GPIO,range from 0 to 3. [Effective] 0:falling edge 1:rising edge 2:disable [Data] The length of customer data is up to 10 bytes.
“AT+ADST=?”(This AT command is related to section 3.3.3). Q: The module can not be connect. A: Check whether the status of the device is in the non-connect state by using AT command “AT+ADST=?”(This AT command is related to section 3.3.3). Q: No reaction when the AT command is sent. A: Check whether the AT Command is end with a “\r”,if there is a “\r”,please remove it. Q: The module can not communicate with the host(the command or data can not be sent through uart port) .
FCC Statement FCC standards: FCC CFR Title 47 Part 15 Subpart C Section 15.247 Integral antenna with antenna gain 0dBi This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.