OPZ1ZT92 Copyright Statement ZiFiSense owns the copyright on this specification. No part of this specification may be reproduced in any form or means, without the prior written consent of ZiFiSense. Disclaimer This specification is preliminary and is subject to change at any time without prior notice. ZiFiSense assumes no responsibility for any errors contained herein. ZiFiSense is not responsible for any patent infringement of third party on its use or as a result of its uses.
OPZ1ZT92 Table of Contents 1. Product Description...............................................................................................................................4 2. Applications........................................................................................................................................... 4 3. Features................................................................................................................................................. 4 4. Specifications.
OPZ1ZT92 1. Product Description ZETA Light Sensor is a low power illuminance detect sensor which is able to quantify the illuminance value and provide alarm signals if the threshold values are exceeded. 2. Applications Room lighting detection, lamp aging detection 3.
OPZ1ZT92 4. Specifications Product No. Wireless Features Electrical Features Physical Features Sensor Characteristics Working Environment OPZ1ZT92 Transmission protocol Frequency band Output power Power supply Battery capacity Stand-by current Working current Size Enclosure material Waterproof level Antenna Range Precision Operating temperature Storage temperature 5.
OPZ1ZT92 6. Installation There are three installation methods: Screw, 3M Adhesive and cable ties. 6.1. Screw 6.1.1.Auxiliary material No. 1 2 3 4 Materials self tapping screw (M3*20) #4 expanded plastic pipe Percussion drill,#4 drill bit,hammer slotted screwdriver, cross screwdriver 6.1.2.Installation instructions Quantity 2/device 2 1 1 Open the device case Use a slotted screwdriver to open the top cover from the bottom edge.
OPZ1ZT92 Use the self-tapping screws to secure the device in the mounting position. mounting hole mounting hole Power on Insert the power plug into the upper power socket, install two 14505 batteries (remove the insulation sheet for the existing battery), and close the upper cover.
OPZ1ZT92 6.2. Adhesive 3M 6.2.1.Auxiliary material No. 1 2 Materials 3M seamless thickened double-sided adhesive Slotted screwdriver, utility knife Quantity 5CM 2 6.2.2.Installation instructions Installation position Select a flat mounting position, and clean it up. Open the device case Use a slotted screwdriver to open the top cover from the bottom edge.
OPZ1ZT92 power socket Adhesive device Take the appropriate amount of 3M adhesive, attach it to the back of the sensor, remove the protective film of the 3M adhesive, and install the device to the specified position. 6.3. Cable Ties 6.3.1.Auxiliary material No. 1 2 Materials Metal cable ties(5*300mm) Slotted screwdriver, utility knife Quantity 2 6.3.2.Installation instructions Open the device case Use a slotted screwdriver to open the top cover from the bottom edge.
OPZ1ZT92 opening Fixation Pass the 2 cable ties through the device and secure to the installation rod Installation position 10
OPZ1ZT92 Power on Insert the power plug into the upper power socket, install two 14505 batteries (remove the insulation sheet for the existing battery), and close the upper cover.
OPZ1ZT92 7. Use of Device 7.1. Steps for usage Place the device within the coverage of the ZETA network Install the battery, and wait for the device to go online. After the device is online, the current device status is reported. According to the usage scenario, set the policy configuration such as alarm enable status and alarm threshold. Daily maintenance and data viewing. 7.2. Support function Version number: Report the software version number of the sensor only once after power-on.
OPZ1ZT92 current light intensity, alarm enable information. Query version number: You can query the software version number of the current sensor. 8. Common faults and handling Ensure ZETA signal coverage Ensure that the device is powered on, and the ZETA network device management platform can observe that the ZETA module is on line Check the battery usage of the device. When the battery is low, replace the battery in time.
FCC WARNING Any Changes expressly or modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
OPZ1ZT92 14