AM100 Series User Guide Safety Precautions Ursalink will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide. The device must not be disassembled or remodeled in any way. Do not place the device outdoors where the temperature is below/above operating range. Do not place the device close to objects with naked flames, heat source (oven or sunlight), cold source, liquid and extreme temperature changes.
AM100 Series User Guide Contents 1. Overview..........................................................................................................................................5 1.1 Description............................................................................................................................ 5 1.2 Features.................................................................................................................................5 1.3 Specifications........................
AM100 Series User Guide 8.2 Add a Ursalink LoRaWAN Gateway..................................................................................... 28 8.3 Add AM100/AM102 to Cloud..............................................................................................
AM100 Series User Guide 1. Overview 1.1 Description AM100 series is a compact indoor ambience monitoring sensor including motion, humidity, temperature, light, TVOC, CO2, barometric pressure for wireless LoRa network. AM100 series is a battery powered device and is designed to be wall-mounted. It is equipped with NFC (Near Field Communication) and can easily be configured via a smartphone or a PC software. Sensor data are transmitted in real-time using standard LoRaWAN protocol.
AM100 Series User Guide PIR Detection Area 94 ° Horizontal, 82 ° Vertical Detection Distance 5m Output Range 0-65535 Light Range 60000 lux (Visible + IR, IR) Accuracy ±30% CO2 Range 400 - 5000 ppm Accuracy ±30 ppm or ±3 % of reading TVOC Range 0 - 60000 ppb Accuracy ±15 % Long-term Stability 1.3 % accuracy drift per year N/A Barometric Pressure Range 300 - 1100 hPa (-40°C - 85°C) Accuracy ±1 hPa Display & Configuration Display Configuration 2.13-inch Black&White E-Ink Screen 1.
AM100 Series User Guide 1.4 Dimensions(mm) 2.Hardware Introduction 2.1 Packing List 1× 2× 1× 2× 1× 1× AM100/AM102 AA Batteries Mounting Mounting Warranty Quick (LR6) Sticker Screws Card Guide If any of the above items is missing or damaged, please contact your Ursalink sales representative. 2.
AM100 Series User Guide Back Panel: ⑥Power button ⑦Battery Cover ⑧Mounting Holes ⑨Type-C Port E-ink Screen: ①Battery Level ② Network Status Activated De-activated ③Temperature ④Humidity ⑤Time ⑥Date 3. Power Supply 3.1 Battery Installation Remove the battery cover and install two new AA/LR6 batteries. Batteries can be replaced on the fly. 3.2 External Power Supply AM100 series can be powered by type-C USB port (5V, 100mA).
AM100 Series User Guide Note: External power can't be used for charging battery. 4. Sensor Installation 4.1 PIR Detection Range There should not be any isolates or barriers in PIR detection range. 4.2 Installation Note In order to ensure the best detection and LoRaWAN communication effect, it is recommended to install AM100 series as follows: There should not be any isolates or barriers in PIR and light detection range.
AM100 Series User Guide 4.3 Wall Mounting 1. Attach the mounting sticker to the wall. 2. Mark the wall where the two mounting holes are according to the sticker’s mark(around 88mm). Note: The connecting line of two holes must be a horizontal line. 3. Drive two screws into wall at the marks using screw driver. 4. Mount the device on the wall. 5. Turn ON/OFF the Sensor AM100 series can be turned ON/OFF via smartphone or computer with NFC (Near Field Communication) or button.
AM100 Series User Guide 5.1 Turn ON/OFF via Smartphone APP 1. Download Ursalink configuration APP “Toolbox” and install it on your smartphone. The smartphone must support NFC. 2. Enable NFC on the smartphone and open the APP. 3. Attach the smartphone with NFC area to the device. Note: Ensure the location of your smartphone NFC area and it is recommended to take off phone case before using NFC. 4. Device information will be shown on the APP. 5.
AM100 Series User Guide 5.2 Turn ON/OFF via PC Software 1. Download Ursalink configuration software “Toolbox” and open the software. 2. Connect NFC reader to computer and attach the device to NFC reader. 3. Select type as NFC and serial port of NFC reader, then click “save”. 4.Device information will be shown on the software.
AM100 Series User Guide 5.Click “Power On” to turn on the device or “Power Off” to turn off the device. 6.Enter password (Default password:123456) and press Enter key to change device status. 5.3 Turn ON/OFF via Button Press and hold on the power button on the back panel for 3 to 10s to turn on or off the device. Press and hold on the power button on the back panel for over 10s to reset the device to factory default. 6.
AM100 Series User Guide 6.1.1 Read Configuration 1. Open APP “Toolbox” and click “Read” to read current information of device. 2.Attach the smartphone with NFC area to the device until the APP shows “Read Successful !”. Note: “Read Failed!” can be caused by long distance, wrong location or rapid movement. 6.1.2 Write Configuration 1. Open APP “Toolbox” and go to “Settings” page. 2. Change parameters as required and click “Write”.
AM100 Series User Guide 3. Enter password (default password: 123456). 4. Attach the smartphone with NFC area to the device and wait a few seconds until APP shows “Write Successfully!”. The device will automatically re-join the network if LoRaWAN paramters are changed. Note: ”Write Failed” can be caused by long distance, wrong location, or rapid movement. 6.1.3 Template Settings Template settings are used for easy and quick device configuration in bulk.
AM100 Series User Guide 1. Go to “Template” page of APP and save current settings as a template. 2. Attach the smartphone with NFC area to another device. 3. Select the template file from Toolbox and click “Write”. 4. Enter password of this device and keep the two devices close until the APP shows “Write successful!”.
AM100 Series User Guide 5. Slide the template item left to edit or delete the template. 6.2 Configuration via PC Make sure “Toolbox” is downloaded on your computer. 6.2.1 Read Configuration 1. Open software “Toolbox” and click “Read” to read current information of device. 2.Attach the device to the NFC reader until Toolbox shows “success”. Note: Failing to read can be caused by long distance, wrong location, or rapid movement.
AM100 Series User Guide 6.2.2 Write Configuration 1. Go to “Settings” page to change parameters as requirements and click “save”. 2. Click “Write” and enter the correct password (default password: 123456). 3. Press Enter key to write and attach the device close to NFC reader until “Write” button disappear. The device will automatically re-join the network if LoRaWAN paramters are changed.
AM100 Series User Guide Note: Keep the two devices close and don’t move them in order that you can get the best connectivity as possible when upgrading. Failing to upgrade can be caused by long distance, wrong location, or rapid movement. 6.2.3.2 FOTA 1. Make sure your computer can access the Internet. 2. Click “Check for Updates” to search for the latest firmware via computer Internet and upgrade.
AM100 Series User Guide 3. Click”Browse” to select the correct template from computer. 4. Click”Import”to import the template to the device. 6.2.4.2 Reset Click the”Reset” to reset the setting to factory default.
AM100 Series User Guide 7. Sensor Parameters (for App and PC) 7.1 LoRa WAN Settings 7.1.1 Basic Settings-OTAA Location: Ursalink ToolBox (PC): LoRaWAN Settings → Basic Ursalink ToolBox (APP): Device → Settings → LoRaWAN Settings Basic Settings-OTAA Item Description Enter the application EUI. The Network Server receives request and consults the entity associated with the App EUI APP EUI to validate the request. If permission is granted, it responds with a join-accept message. Select from: "OTAA" and "ABP".
AM100 Series User Guide After sending the attribute/data/battery packets to the network server, the device will resend these packets if it does not receive ACK bit from the Network Server. Confirmed Mode ADR Note: If the device doesn't receive ACK for a long time, the device will resend confirmed packets 3 times at most. However, the device will resend attribute package all the time. ADR : Adaptive Data Rate. Enabled: The Network Server will adjust the datarate by MAC command.
AM100 Series User Guide Under certain circumstances, end-devices can be activated by personalization. Activation by personalization directly ties an end-device to a specific network by-passing the join request - join accept procedure. Device Address Network Session Key Application Session Key Enter the device address. The device address identifies the end-device within the current network. Enter the network session key of the device. The network session key specific for the end-device.
AM100 Series User Guide LoRa frequency configuration is as follows if the sensor LoRa frequency is one of EU433/EU868/RU864/IN865/AS923/KR920: LoRa frequency configuration is as follows if the sensor LoRa frequency is one of CN470/US915/AU915: Enter the index of the channel to be enabled in the input box, separated by commas.
AM100 Series User Guide 8 channels numbered 64 to 71 utilize LoRa 500 kHz BW starting at 903.0 MHz and incrementing linearly by 1.6 MHz to 914.2. For AU915: 64 channels numbered 0 to 63 utilize LoRa 125 kHz BW starting at 915.2 MHz and incrementing linearly by 0.2 MHz to 927.8. 8 channels numbered 64 to 71 utilize LoRa 500 kHz BW starting at 915.9 MHz and incrementing linearly by 1.6 MHz to 927.1. For CN470: 80 channels numbered 0 to 79 utilize LoRa 125 kHz BW starting at 470.
AM100 Series User Guide Ursalink ToolBox (APP): Device → Settings → Data Collection Settings Note: The data displayed on the screen is the current value. The data reported to the gateway is the average of the reporting interval. 7.2.2 Data Calibration Location: Ursalink ToolBox (PC): Device Settings → Data Calibration Settings Ursalink ToolBox (APP): Device → Settings → Data Calibration Settings Data Calibration Settings Item Enable Current Raw Value Calibration Value Description Enable calibration.
AM100 Series User Guide Humidity Calibration Illumination Calibration TVOC Calibration (AM102 Only) CO2 Calibration (AM102 Only) Barometric Pressure Calibration (AM102 Only) Enter the calibration value for humidity. Note: only integer is allowed. Enter the calibration value for illumination. Note: only integer is allowed. Enter the calibration value for TVOC. Note: only integer is allowed. Enter the calibration value for CO2. Note: only integer is allowed.
AM100 Series User Guide 8.2 Add a Ursalink LoRaWAN Gateway 1. Enable “Ursalink” type network server and “Ursalink Cloud” mode in gateway web GUI. Note: Ensure gateway has accessed the Internet.
AM100 Series User Guide 2.Go to “My Devices->Gateway” of Ursalink Cloud and click “Add” to add gateway to Ursalink Cloud via SN. 3.Check if gateway is online in Ursalink Cloud. 8.3 Add AM100/AM102 to Cloud 1. Go to “Device->My Devices” and click “Add Device”. Fill in the SN of EM500-SWL and select associated gateway. 2.After AM100/AM102 is connected to Ursalink Cloud, Click or “History Data” to check the data on Ursalink cloud.
AM100 Series User Guide 3.Go to “Dashboard” page to add dashboard.
AM100 Series User Guide FCC Caution: Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.