Installation Instructions

Smart Switch Installation
Instructions Manual
Model No. SNA042CLR3-ZB-1X600-
Rated Voltage 120-277V~
Rated Frequency 60Hz
Operating Voltage
120V~ 277V~
Load Range
Incand. 5A 3A
LED/CFL 5A 3A
Res 5A 3A
Motor 1/6 HP 1/6 HP
Communication
module
ZigBee
Operating
Environment
Temperature 0 - 40
Humidity10% R.H. - 90% R.H.
Usage Environment
Indoor use only
Model Size 105 mm×44 mm×33mm (L×W×H)
Model No. SNA042CLR3-ZB-1X1200-
Rated Voltage
120-277V~
Rated Frequency
60Hz
Operating Voltage
120V~ 277V~
Load Range
Incand. 10A/1200VA 8A/ VA
LED/CFL 10A/1200VA
Res 10A/1200VA
Motor 1/2 HP 1 HP
Communication
module
ZigBee
Operating
Environment
Temperature 0 - 40
Humidity10% R.H. - 90% R.H.
Usage Environment Indoor use only
Model Size 105 mm×44 mm×33mm (L×W×H)
!
WARNINGSAND CAUTIONS
To protect against the dangers of fire and electric shock, a
product has to be installed according to electrical codes and
standards.
This product should be use together with an upstream
air-switch.
Turn power off at circuit breaker or fuse and test that power is
off before installing.
If you are unsure about any part of these instructions, consult a
licensed electrician.
RF EXPOSURE STATEMENT
This equipment complies with the FCC RF radiation exposure limits
set forth for an uncontrolled environment. This equipment should be
installed and operated with a minimum distance of 20cm between the
radiator and any part of your body.
This equipment meets the exemption from the routine evaluation
limits in section 2.5 of RSS-102. It should be installed and operated
with a minimum distance of 20cm between the radiator and any part
of your body.
Cet équipement est conforme à l'exemption des limites d'évaluation
habituelle de la section 2.5 de la norme RSS-102. Il doit être installé
et utilisé à une distance minimale de 20 cm entre le radiateur et toute
partie de votre corps.
IC Information
This device contains licence-exempt transmitter(s) that comply with
Innovation, Science and Economic Development Canada’s
licence-exempt RSS(s). Operation is subject to the following two
conditions:(1) This device may not cause interference.and (2) This
device must accept any interference, including interference that may
cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent
appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes:
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même
si le brouillage est susceptible d’en compromettre le fonctionnement.
FCC Information
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
This device may not cause harmful interference, and (2) This device
must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician
for help.
FCC CAUTION
Any changes or modifications to this unit not expressly approved
by the manufacture could void the user's authority to operate the
equipment.
Function Parts Information
RESET
RESET
Short press: Within 0.5s .
Long press: Over 5s.
Status Indicator
Indicator lights red: OFF status.
Indicator lights green: ON status.
Green Indicator flashing: enter distribution network mode.
ON/OFF
Load power ON: When the load is powered off, press the ON
button once.
Load power OFF: When the load is powered on, press the OFF
button once.
Network mode: when the light is on, Long press ON or OFF for
5 seconds. After the status indicator blinks quickly, the phone
can be connected to the smart switch. (if it is not connected, exit
the network mode after 3 minutes).
Self-reset Switch
Network mode: when the light is on, Long press the reset switch
for 3 seconds. After the status indicator blinks quickly, the
phone can be connected to the smart switch. (if it is not
connected, exit the network mode after 3 minutes).
Power Cut -off Button
Put in the power cut-off button to connect the power.
Put out the power cut-off button to cut off the power.
Parts Information
RESET
Smart Switch
1pc
Jumper Wire(1pc)
Mounting
Frame(1pc)
Panel(1pc)
P3 Wire
connectors(6pcs)
Mounting
screw(2pcs)
Tools needed to install your smart switch
Φ3mm Slotted
Screwdriver
Φ5mm Philips
Screwdriver
Electrical
Tape
Cutters
Pliers Test Pencil Ruler
Installation and testing
Step 1
!
WARNING: To avoid fire and electrical shock,TURN
OFF POWER at circuit breaker or fuse and test that power is off
before wiring.
Step 2 Removing existing switch: Remove existing wall plate and
switch mounting screws. Carefully pull switch from wall box, identify
and take out the wires attached to the switch, then remove the switch.
DO NOT remove wires which are taken out from the switch at this
time.(If new configuration is without this step)
Step 3 Identifying your wiring application
NOTE:If the wiring in the wall box does not resemble any of
these configurations, consult an electrician.
Single-Pole
①Line (Hot)
②Neutral
③Ground
④Load
3-Way
①Line or Load
(See note below)
②Neutral
③Ground
④Traveler 1
⑤Traveler 2
Self-reset switch
Status Indicator
Power Cut -off Button
ON
OFF
P
P
2216