Safety Handling • • • • • WARNING: Failure to follow these safety notices could result in fire, electric shock, other injuries, or damage to the Thermostat and other property. Read all the safety notices below before using the Thermostat. Avoid high humidity or extreme temperatures. Avoid long exposure to direct sunlight or strong ultraviolet light. Do not drop or expose the unit to intense vibration. Do not disassemble or try to repair the unit on your own.
Overview of this guide Part 1 Welcome Page4 A brief introduction to the smart thermostat Page4 Products in the box Page5-8 Check your old thermostat, and choose the guide you need Part 2 Part 3 Page9-12 In the box Installation Guide Installing with a C-wire Page13-21 Installing without a C-wire (Optional) Page22-24 Wiring diagrams Part 4 Further setup your device Part 5 Meet Your Thermostat Page26-29 Configuration of thermostat Page30-33 Introduction of main interfaces Page34-39 The prompt
1 Welcome The Wi-Fi Touchscreen thermostat makes it easier and smarter to control your household temperature. With the help of zone sensors, you can balance hot or cold spots throughout the home to achieve best comfort. You can schedule your thermostat working hours so it will work based on your plan. This guide will provide you with an overview of the product and will help you understand how to use it. 2 In the box PCT513 Wi-Fi Touchscreen Thermostat Wall Plate 2*Screws Label 1.
3 Installation Guide 3-1 Removing your old thermostat Step 1. Switch off your HVAC system Before you start, please switch off your HVAC system to protect you and avoid blowing a fuse. Wait a few minutes, try to adjust the temperature in your old thermostat to double check if the system is off. Breaker box Switch Step 2. Remove the old thermostat Remove the old thermostat from the wall, keep the wallplate with wires.
Step 3. Compatibility Check If you find a thick wire with wire nuts on the backplate of the old thermostat, or if the voltage of your old system is 120v or higher, it will not be compatibled with PCT513. If none of the above, then please proceed to the next step. OR 120V or higher Step 4. Take a photo Take a picture of the wires connected to the terminal of your old thermostat. You may need to reference this photo later.
Step 5. Label the Wires with Tags Label each wire on the wallplate with the tags (label 1) provided. Then carefully disconnect the wires. RC G Y1 W1 C RC RH G Y1 Y2 W1 W2 C O/B Note: If there are any jumper wires between Rh, Rc, or R terminals, do not label them. PCT513 does not need jumpers. Remove them and save along with your old thermostat.
3-2 Connect wires Do you have a C wire connected to your old thermostat? YES → 3-2-1 RC NO → 3-2-2 G Y1 W1 C RC RH G Y1 Y2 W1 W2 C O/B Terminal designation: Terminals RC RH C W1 W2 Y1 Y2 G O/B S What it means 24VAC primary for cooling 24VAC primary for heating 24VAC common 1st stage Primary heating relay / Aux heat 2nd stage Secondary heating relay / Aux heat 1st stage Primary compressor contactor 2nd stage Secondary compressor contactor Fan relay Changeover valve for heat pumps Optional wiring mod
3-2-1 Install the thermostat with a C-wire Step 1. Remove the wallplate Unscrew the wallplate from the wall, gently pull it out to ensure the wires ↑ ↑ will not fall back into the hole. RC G Y1 W1 C RC RH G Y1 Y2 W1 W2 C O/B Step 2. Attach the base of PCT513 to the wall Bundle and insert the wires through the hole of wall plate and the base of PCT513, then attach the base to the wall with the screws.
Step 3. Connect the wires Connect wires to the corresponding terminal in the base. Take a picture of the wires when you finished. You may need to refer it for the wirings in the setup wizard later.
Step 4. DIP Switch Adjust the DIP switch on the back of the thermostat to 'Disconnect' if you have connected both the RC-wire and the RH-wire to the wallplate, otherwise, switch it to the 'Connect' side. DIP switch RC&RH Connect Disconnect Step 5. Attach the PCT513 to the base Gently press the PCT513 into the base until it clicks.
Step 6. Power on your system Congratulation! The installation is finished. Please power on your HVAC system. Breaker box Switch When the power is successfully energized, the thermostat's screen will light up and go into wizard. You can complete the following configuration according to section 4.
3-2-2 Install the thermostat without a C-wire (Optional) Power module Power module requires your system to have the following wires: 4 wires: W/W1, Y/Y1, G, and R (or Rc or Rh) or 3 wires: Y/Y1, G, and R (or Rc or Rh) RC G Y1 W1 RC RH G Y1 Y2 W1 W2 C O/B If you do not have these wires, your system may not be compatible with the power module.
Description: The C-wire is used to provide power to the thermostat. If your system does not have "C" wire, you can use the power module to power your thermostat using the exiting wires. To HVAC control board To thermostat Power module There are two sides with connections. One side (4 terminals) is for thermostat connections, the other side, pre-wired (5 terminals), is for the control board connections.
Step 1. Find the HVAC terminals Find the control board of your HVAC system. Open your HVAC system’s cover and take a picture of the wires connected to the terminals of your old thermostat. You may need to reference this photo later. HVAC Control Board W C G Y R W → C G Y R → Step 2. Label the wires Label only the wires from the control board to your old thermostat with the tags provided (label 2 control board). Label 1.
Step 3. Disconnect the wires Disconnect the W/W1, G, Y/Y1, R wires from the control board. Control Board ↓ W C G W G R Y R Y To thermostat Step 4. Connect the wiring module Reconnect them correspondingly to the 4 terminals side of the power module.
Step 5. Connect the wires Generally, the control board will have W, C, G, Y, R terminal, connect the pre-wired side of the power module (5 terminals) to the corresponding terminals. HVAC Control Board W C G Y R W G Y R To HVAC control board To thermostat Power module Step 6. Position the wiring module The power module should be installed between your thermostat wiring and your control board.
Step 7. Add new tags Add new tags to the following tags to simplify your wiring: R/RC/RH→ RC Label 1. C C If you have a C wire, you will not need the label 2 below. R RC RH O/B * R G RC Y/Y1 RH Y2 G→ C G Y/Y1 Y2 O/B W/W1 W/W1 * W2 W2 Label 2. RC S RC C S R RC RH R RC RC Thermostat Control board C Y/Y1→ S G G C RC W/W1 W/W1 RH Y/Y1 Y/Y1 G Y1 W1 S RC RH G Y1 Y2 W1 W2 C O/B Step 8.
Step 9. Attach the base of PCT513 to the wall Bundle and insert the wires through the hole of wall plate and the base of PCT513, then attach the base to the wall with the screws. Base ↑ ↑ Wall plate Step 10. Connect the wires First, connect 3 wires as shown below: ↑ RC, C, S Y1 Y2 M2 RC RC Y1 C G C RH O/B W1 W1 M1 S S RC G W2 Then connect other wires to the corresponding terminal in the base. Take a picture of the wires when you finished.
Step 11. DIP Switch Adjust the DIP switch on the back of the thermostat to the 'Connect' side. DIP switch RC&RH Connect Disconnect Step 12. Attach the PCT513 to the base Gently press the PCT513 into the base until it clicks.
Step 13. Power on your system Congratulation! The installation is finished. Please power on your HVAC system. Breaker box Switch When the power is successfully energized, the thermostat's screen will light up and go into wizard. You can complete the following configuration according to section 4.
Wiring diagrams Below are the wiring diagrams for common HVAC equipment. Conventional heating and cooling system G RC Y1 RH S C Y2 O/B M2 W2 M1 W1 Y1 Y2 C Air conditioner Y1 Y2 W1 W2 R Furnace C G For dual heat and cooling system, if applicable. Remove the jumper between Rh, Rc, or R terminals, adjust the DIP switch on the back of the thermostat to 'Disconnect' if you have connected both RC-wire and RH-wire to the wallplate, otherwise switch it to the 'Connect' side.
Heat pump (air or geothermal) with auxiliary heat G RC Y1 RH S C Y2 O/B M2 W2 M1 W1 O/B W1 W2 Y1 Heat pump Y2 R C O/B W1 W2 Y1 Y2 Air handler G R C For dual heat and cooling system, if applicable. Remove the jumper between Rh, Rc, or R terminals, adjust the DIP switch on the back of the thermostat to 'Disconnect' if you have connected both RC-wire and RH-wire to the wallplate, otherwise switch it to the 'Connect' side.
Boiler or radiant system with air handler and conventional cooling or heat pump G RC Y1 RH C S Y2 O/B M1 W1 M2 W2 Air handler Y1 Y2 R Y1 Y2 C C G O/B1 Air conditioner or Heat pump W1 R W2 Boiler For dual heat and cooling system, if applicable. 1 For heat pump only.
Congratulations, you have completed the wiring! To complete your setup, follow the instructions on the configuration guide below.
4 Get started 4.1 To get started, you will need: • Connect your smart mobile phone to your home Wi-Fi network. • A mobile phone with a 'SmartLife' APP installed. Follow the wizard first to complete the thermostat setup based on your HVAC system. 4.2 Configuration: FRI 12:00 ← 1. Click the Wi-Fi icon on the home screen to configure Wi-Fi. 27.5 42% Cool to 26.
2. Select the network configuration mode. It may take a while to switch between the two modes. • EZ Mode (Default): To pair devices quickly. You can set all devices to this mode, and then add devices in batches on your phone. • AP Mode: If there are many devices, while you only want to pair one device. You can refer to FAQ 6.4 to configure network in this mode. 3. Open your APP. 4. Login with an existing account. If you are a new user, create an account first. 5.
7. Enter your home Wi-Fi account and password (Only support 2.4Ghz WiFi), then tap "Next" button. 8. Place the router, mobile phone and thermostat as close as possible to waiting for connection. Confirm the indicator on your device is rapidly blink, then tap "Next".
9. After successful connection, you can rename the thermostat and click "Done" to complete.
5 Meet Your Thermostat 5.1 Device Overview Main page Date&Time Indoor temperature FRI 12:00 Fan mode Hold mode Weather&Indoor Humidith Locked 27.5 42% Heat to 16.0 Cool to 29.0 Follow Schedule Menu Wi-Fi Turn up Target temperature Turn down System mode You can select the heating/cooling target temperature to adjust separately or press the up and down buttons to adjust it simultaneously.
• Heat: Heating only • Cool: Cooling only • Auto: Automatic control of heating and cooling based on ambient temperature • • Emergency Heat: This only works when the device connects Heat pump and W wire Off: Turn the system off Fan mode • Fan ON Auto Cir • On: Runs continuously • Auto: Automatically adjust fan according to the system mode • Cir: Runs at intervals to circulate air 31
Hold mode There are three hold modes you can select • Hold Temporary Hold • Permanent Hold Remove Hold Follow Schedule: Follow the settings of schedule to adjust the temperature. When you remove hold, the mode will turn to 'Follow Schedule' • • Permanent Hold: Always hold the current target temperature even meet the schedule. Temporary Hold: Keep the current target temperature until the next scheduled activity begins.
FRI 12:00 27.5 42% Hold until 14:00 Heat to 16.0 Cool to 29.0 Undo Hold temperature until next schedule Vacation mode You can set the vacation mode in 'Menu'->'Vacation'. Set the time of departure and return, as well as the highest and lowest temperatures during this period. The thermostat will automatically hold this temperature range. FRI 12:00 27.5 42% Follow Vacation Heat to 16.0 Cool to 29.0 Note: When the thermostat is under this mode, you cannot manually change the target temperature.
Display Here are some changes on the screen and what those mean: 1 FRI 12:00 Red: Heating 22.5 42% FRI 12:00 Heat to 23.0 Cool to 26.0 Follow Schedule Blue: Cooling 27.5 42% Follow Schedule Heat to 23.0 Cool to 26.0 2 FRI 12:00 31.0 42% Heat to 16.0 Cool to 29.0 Stars in 01:18 Compressor Protection Time When you turn on the compressor frequently, there will be a time countdown to protect the compressor.
3 When the outdoor temperature is below the 'Compressor Min Outdoor Temp' you set, the icon on system mode will display and the compressor will be turned off automatically. When the outdoor temperature is higher than the 'AUX Heat Max Outdoor Temp' you set, the icon on system mode will display and the AUX Heat will be turned off automatically. 4 The thermostat is connected to the router, but the router is not connected to the network There may be a problem with the Cooling.
Menu • Memu System Weather Sensors Vacation Lock Settings Schedule System • HVAC: Switch system mode (Heat/Cool/Auto/Emergency Heat/Off) • Fan: Switch fan mode (ON/Auto/Cir) Weather(Reserved) (In development). Sensors Add multi sensors to balance the current temperature throughout the home. Schedule Set schedule to change the temperature automatically. Vacation Set vacation to change the temperature automatically. Lock Multi-level keypad lockout to avoid others tampering with the settings.
corresponding settings icon will go dim. An icon of a small lock will appear on top of main page. • • • • Settings Date &Time: Set time format. You can also set the time manually when the device is not configured with a network. Fan Run Time: Set minimum fan run time in 'Cir' mode Wi-Fi: Display Wi-Fi information. Configurate or reset Wi-Fi.
When the heating/cooling stops, the fan shuts off with a delay. 2. Compressor Protect Time A time countdown to protect compressor to start frequently. 3. Compressor Min Outdoor Temp When the outdoor temperature is below this temperature, the compressor will not be used. 4. Compressor/(Aux) Heat min on time during heating/cooling cycles 5.
Reset setting Reset schedule (Reset system schedule and clear vacation) • Reset all (reset the thermostat to default factory setting) About: Show device information 5.
Home: 1. Device list You can check the added device, tap one to enter control page. You can drop it down to refresh the list. 2. Location information Information about your local weather conditions 3. Home management Add or delete home and manage home names, rooms, locations, and members 4. Room management Manage room. You can create rooms and assign devices to each room 5. Voice control (In development) 6. Connection Prompt The prompt show up when the App can't connect to the thermostat.
Control page Indoor Humidity Device management Fan is working Indoor temperature Target temperature System mode Fan mode Hold mode Setting • System mode: Displays the current system mode. Tap it to switch the mode. • Fan mode: Displays the current fan mode. Tap it to switch the mode. • Hold mode: Displays the current hold mode. Tap it to switch the mode. • Device management: You can remove device, change device name, update firmware or share device.
6 FAQ 1.How to pair the thermostat with Remote Zone Sensors ? 1. Click the '+' button at the top right of the interface in 'Menu' -> 'Sensors' on the thermostat and tap 'Next'. • Sensors Pair Please press and hold the button on the back of the sensor for 3 seconds, the indicator will flash red, then tap ‘Next’. Next 2. Remove the rear cover of the sensor. 3. Press and hold the button on the back of the sensor for 3 seconds until the indicator on the front of the sensor flash red. 4.
2. Wi-Fi configuration of the thermostat failed - Confirm the device, mobile phone, and router are as close as possible. - Please confirm the network is stable: Put the phone besides your device and make sure they are in the same network environment, try to open a website to judge if the network can be used. - Confirm adding device is under 2.4G WI-FI channel. If 2.4G and 5G WIFI use the same name, it is recommended to change to a different name. - Confirm the entered router password is correct.
4. Configure the network in AP mode FRI 12:00 ← 1. Click the Wi-Fi icon on the home screen to configure Wi-Fi. 27.5 42% Cool to 26.o Follow Schedule 2. Select the AP mode. It may take a while to switch between the two modes. 3. Open your APP. 4. Login with an existing account. If you are a new user, create an account first. 5. Please click the '+' button at the top right corner of the App to add devices. 6. Select 'Thermostat' in "Small Home Appliances" list to add manually.
← ← 7. Enter your home Wi-Fi account and password (Only support 2.4Ghz WiFi), then tap "Next" button.
8. Switch the network configuration mode to AP mode at the upper right corner of the APP. Then confirm the indicator on your device is slowly blink, tap "Next". ← 9. Place the router, mobile phone and thermostat as close as possible to waiting for connection. Confirm the indicator on your device is slowly blink, then tap "Next".
10. Find and connect the device's hotspot in the Wi-Fi list. 11. After the connection succeeds, you can rename the thermostat and click "Done" to complete the configuration.
Technical specifications Thermostat: Compatibility Compatible systems System Mode Fan Mode Advanced • Conventional: 2-stage heating and 2-stage cooling HVAC systems • Heat Pump: 2-stage heating, 2-stage cooling, 2-aux heating • Supports natural gas, electric, hot water, steam or gravity, gas fireplaces (24 Volts), oil heat sources • Supports heat pump, dual fuel HVAC Control Functions • Heat, Cool, Auto, Off • Emergency Heat (Heat Pump only) • On, Auto, Circle(adjustable) • Setting temperature local
Wireless Connectivity Wi-Fi Radio LCD Screen • 802.11 B/G/N20/N40 @ 2.4GHz • 915MHZ Physical Specifications • 4.3-inch color touch screen PIR Sensor • Sensing Distance 3m, Angle 70° Electrical Rating • 24 VAC, 1A Carry; 5A Surge 50/60 Hz Max. Load Current • 1A Operating Environment Storage Temperature Wiring Dimensions Mounting Type • 0~ 50° C, 32 ~122° F • Humidity range: 5%~95% • -30 ~ 60° C , -22° F ~ 140° F • 18 AWG, Requires both R and C wires from the HVAC System • 131(L) × 78 (W)× 29.
Remote Zone Sensor: Battery • DC 3V (2*AAA batteries) Radio • 915MHZ LED • 2-color LED (Red, Green) PIR Operating Environment Dimension Mounting Type • Detect occupancy • Sensing Distance 5m, Angle 120° • 0~ 50° C, 32 ~122° F (Indoor only) • Humidity range: 5%~95% • 62(L) × 62 (W)× 15.