User's Guide

User Guide
WIFI TYPE
Welcome
Thank you for your purchase.
In the box you will find
Thermostat
Screws
User Guide
1pc 4pc
2pc
QC Passed
1pc
SYSTEM TYPE
FEATURES
On Appearance
2. 4.8 inch large colorful display creates your colorful life.
4. Amazing silver frame opens your modern life.
7. Wall mounted
and Italy etc,.
10. 12 terminals are available for many systems.
2. 1/0.5accuracy keeps temperature within the level you set.
3. or choice.
4. 7 days four periods programmable.
5. Temporary programmable.
6. Holiday mode.
8. No limit to add thermostats in App.
9. Support Smart Scene.
10. Support to make two stage grouops.
11. Support device sharing.
12. Weather, UV index, humidity display help you decide what to wear today.
BHP-8000 Room Thermostat
Your new thermostat will provide uniform and comfortable temperature
control throughout every room in your peoperty. We bring together technology,
reliable product combined with sleek, contemporary design. Please read this
1. Warm air, hot water, high efficiency furnaces, heat pumps, steam, gravity.
2. Heat only--including power to open and close zone valves, and normally
open zone valves.
3. Heat only with fan.
4. Cool only.
TECHNICAL DATA
Power Supply: 24VDC/AC ±10%
Sensor: NTC3950, 10K
Set Temp. Range: 42-122(5~50)
Accuracy: ±1
Display Temp. Range: 41~210(5~99)
Ambient Temp: 32~113(0~45)
Ambient Humidity: 5~95%RH(Non Condensing)
Storage Temp: 23~113 (-5~45)
DIMENSION
Unit: mm (inch)
Timing Error: <1%
Shell Material: PC+ABS(Fireproof)
Hole Distance of 86±3mm (USA and Italy etc,.)
Wire Terminals: Wire 2×1.5mm2 or 1×2.5mm2
INSTALLATION
For wiring , please refer to another page.
CAUTION
Electrical Shock or Equipment Damage Hazard. Can shock individuals or
short equipment circuitry.
HOME SCREEN QUICK REFERENCE
1 2
3
4 5 6 87 9
10
11
12
13
141516171819
20
21
22
23
24
25
26
1
Wifi(AP mode)
4
2
3
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Wifi(EZ mode)
AUX Heat
1st Stage Heat
1st Stage Cool
Fan
Wind speed
Weather
Periods
Monday to Sunday
External sensor
Ultraviolet intensity
Outdoor Humidity
Down Button
Up Button
Clock
Permanent Hold/Temporary
Hold/Using Schedule/Hold Until (holiday)
Auto/Cool/Heat/Off/EMER
Power on/off
Time Display
Set temp.
Menu
Room Temp.
Fan On/Auto
System mode
26
Lock/Unlock
27
27
Filter Reminder
COOL — Thermostat controls the cooling system.
EMER — Emergency heat cycles to maintain temperature. Compressor is
locked out (used only for 2H/1C or 3H/2C heat pump systems) and auxiliary
heat turns on as second stage if needed.
:
Press to set the Permanent Hold, Temporary Hold, Using Schedule
Permanent Hold - Manual. In this mode, press / to set
temperature by manual.
Temporary Hold. During Using Schedule or in this mode, press /
next scheduled period.
Using Schedule. 7 days a week, four periods programmable daily.
Holiday Mode.
of days.
Press
Touch the icon / to set your minute.
Then press ,
; Touch the icon / to
set your hour.
Then press
set your week.
How to adjust your schedule?
Press the icon then use the / arrows to set the temp. for the 1st
period. Repeat this process for periods 2-4.
Get Up — Period when you awaken and want your home at a
comfortable temperature.
Go Out — Period when you are away from home and want an
energy-saving temperature.
Go Home — Period when you return home and want your home
back to a comfortable temperature.
Sleep — Period when you are asleep and want an energy saving
temperature.
Schedule Period Time
Setpoints
Heat Cool
Get Up 6:00 AM
72
(22
)
72
(22
)
Go Out 8:00 AM
72
(22
)
72
(22
)
Go Home 11:30 AM
72
(22
)
72
(22
)
Sleep 01:30 AM
72
(22
)
72
(22
)
How to adjust your holiday?
Press
displays and days flash on
the screen then click / arrows to set the days of holiday .
When the flashing of days stops, you can press / arrows
to set the temp. Holiday mode will be valid immediately.
:
Then press to change the dierent items. You can press /
Fact
4.
+1: 2nd Stage Heat
+1: 2nd Stage Cool
2cm (0.787 inch).
increase the
the temperature sensing accuracy.
130.0 (5.12)
103.8 (4.09)
20.9 (0.82)
17.2 (0.68)
104.5 (4.11)
82.3 ± 35.12 ± 0.12
60.0 ± 32.36 ± 0.12
90.0
3.54)
63.8 (2.51)
3. Installer must be a trained, experienced service technician.
BEFORE WIRING AND INSTALLING
Set Temp.
User Setup
Number
Function Setting and options Default
1 Fan ON / AUTO 0: Fan AUTO; 1: Fan ON 0
2 Temperature Calibration -8 ° F to 8 ° F (-4 ° C to 4 ° C) 0
3
Compressor delay time for heat
pump
0-5 minutes 0
4
Changeover Valve—O/B Terminal
Energized in Heating or Cooling
(Heat Pumps Only). Only shown if
heat pump system is chosen.
0: cooling O/B = 0,
heating O/B = 1;
1: cooling O/B = 1,
hea
ting O/B = 0;
1
5 Minimum setting temperature 42 ° F to 62 ° F (5 to 15 ° C) 42℉(5℃)
6 Maximum setting temperature
62 ° F to 122 ° F (15 to 45 °
C)
122℉(45℃)
7 Time display
0: 12-hour clock;
1: 24-hour clock
1
8
Dead-band temperature in Auto
mode for heat pump. Heating and
cooling setpoints can be set no
closer than chosen value. Shown
only if automatic changeover is
selected.
0 ° C to 5 ° C (0 ° F to 10 ° F) 3
9 Filter cleaning reminder 0-5 months 3
A Standby screen brightness 1-99 4
B
Temperature Indication
Scale
0: display; 1: displ
ay 1
C
Deadzone temperature for turning
on/off load
1 ° C to 5 ° C (2 ° F to 10 ° F) 1
D Fan Control in Heating
0: Without control;
1: With control
1
E
Change the system of heat pump
and air conditioning
0: Heat pump
1: Air conditioning
0
Your thermostat can be mounted horizontally on the wall or on a 4 in. x 2 in.
(101.6 mm x 50.8 mm) wiring box.
I
Don’t install your thermostat where it could be affected by:
— Hot or cold air from ducts.
— Radiant heat from sun or appliances.
— Concealed pipes and chimneys.
— Unheated (uncooled) areas.
Fig 1
Step 3. Complete the wiring according to the wiring diagram and select the appropriate
Fig 2
Fig 2
thermostat display panel. See Fig 3.
Fig 2
Fig 3
Step 1. Keep the electricity o.
See Fig 4.
Fig 4
Steps
OPERATION
to turn the thermostat on/off. Press1. Power On/off:
Press to select the mode AUTO, COOL,
HEAT, OFF, EMER
NO
NO
NO
YES
5FEET
(1.5METERS)

Summary of content (3 pages)