User Manual of DP series Handheld Thermal Imaging Camera User Manual of DP series Handheld Thermal Imaging Camera V2.
User Manual of DP series Handheld Thermal Imaging Camera User Manual of DP series Handheld Thermal Imaging Camera Version Date Modified Author Approved By Note number V1.0 202001 New V2.0 202008 Update some specification V2.1 202103 Add human body temperature feature V2.2 202202 Modify © 2021 Shenzhen Dian Yang Technology. All rights reserved. 2021 Copyright Shenzhen Dianyang Technology Co., Ltd. All rights reserved.
User Manual of DP series Handheld Thermal Imaging Camera Contents OVERVIEW.........................................................................................................................................1 1.1 APPEARANCE.......................................................................................................................... 1 1.2 POWER ON/OFF..................................................................................................................... 4 1.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.3.2 2.2.4 Alarm below threshold...................................................................25 WiFi.................................................................................................................... 25 2.2.4.1 Enable and Disable WiFi................................................................. 25 2.2.4.2 WiFi Configuration......................................................................... 25 2.2.5 LED......
User Manual of DP series Handheld Thermal Imaging Camera Overview 1.1 Appearance DP series handheld thermal imaging camera appearance is shown below, ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera The front of DP series handheld thermal imaging camera has 6 buttons, as shown below, OK & Homepage Up arrow Down arrow Left arrow Right arrow Return & Power ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera The back of DP series handheld thermal imaging camera has 1 button, Trigger ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 1.2 Power On/Off Press “Return & Power” key >1 second to power on DP series handheld thermal imaging camera, the thermal imaging will display later. Press “Return & Power” key >3 seconds to power off DP series handheld thermal imaging camera If DP series handheld thermal imaging camera has any abnormal issue, Press “Return & Power” key >8 seconds to force shutdown the camera. 1.
User Manual of DP series Handheld Thermal Imaging Camera Point the lens at the measured object as shown in the figure below, and the infrared image of the measured object will be displayed on the screen. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera If the temperature value is not displayed on the screen, press "OK & Homepage", then select the "Measurement" icon , and then select "Center Spot", "Hot Spot" and "Cold Spot" in the figure below to display the temperature, ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera Press the trigger button will freeze the image as the figure below, ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera As shown in the figure below, you can save the thermal image and visible light image by pressing the "trigger button" or "OK & Homepage", and press the "Return & Power" to cancel saving. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 1.4 Save, Delete and View Infrared Thermal Image Power on the thermal camera. Point the lens to the object. Press the "trigger" to freeze the thermal image and visible light image, continue to press the "trigger" or "OK & Homepage" to save the thermal image and visible light image, press the "Return & Power" cancel saving. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera Press Return will view the saved thermal images and visible images. Every time take pictures will save 3 frames into 1 picture, o 1st frame: the image frame of what you see is what you get ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera o 2nd frame: the raw image frame of thermal image o 3rd frame: the raw image frame of visible light image ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera In the album, press "OK & Homepage" to preview the image in full screen. You can view the 3 frames of each picture by using the up and down arrow keys. The left and right arrow keys select the previous or next picture. When previewing the picture in full screen, press "OK & Homepage" to choose deleting the picture, press "Return & Power" to return to the album. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 1.5 Main Page 1. Current Emissivity 2. Hot spot, cold spot and central spot 3. Time 4. WiFi 5. Battery 6. Color bar 7. Second level menu 8. First level menu 1.6 Control and trigger keys According to the below description to operate control and trigger keys, "OK & Homepage" is only used as the homepage key to open the menu when the main page interface is turned on, other times as the Ok key.
User Manual of DP series Handheld Thermal Imaging Camera 1.7 Charge and Export Pictures 1.7.1 Charge Open the charging and data interface silicone plug then can see the USB interface. You can use the accessory's USB data cable to charge the camera at any time. The camera can still be used during the charging process. The transformer chooses a universal USB interface 5V 2A or larger charger. If the camera is power on and charging, please return to the homepage and press the "OK & Homepage".
User Manual of DP series Handheld Thermal Imaging Camera Operation and Settings 2.1 Main Page Operation 2.1.1 Quick Operation 2.1.1.1 Quick Switch Color Palettes When there is no menu on the main page, you can press the left and right arrow keys to quickly switch between 8 types of color palettes. For details about color palettes, see 2.1.3.4 Color palette. (If the main page displaying visible light image, you cannot switch color palette) 2.1.1.
User Manual of DP series Handheld Thermal Imaging Camera 2.1.2 First Level Menu Power on the camera, press the "OK & Homepage" to display the first-level menu and the status bar on the top. In this state, press the "Return & Power" to close the first-level menu and status bar. The icon selected in the menu is the current operable function, and there is a text prompt on the top of icon. No.
User Manual of DP series Handheld Thermal Imaging Camera Select the image display mode, such as 4 Image Mode picture-in-picture, outline fusion etc. Select the effect of the image, such as high 5 Thermal AGC contrast, gentle and so on. Select the infrared thermal imaging palette, 6 2.1.3 Color palette such as iron, white hot, etc.
User Manual of DP series Handheld Thermal Imaging Camera 2.1.3.1 Measurement The function is shown below, No.
User Manual of DP series Handheld Thermal Imaging Camera 2.1.3.2 Image Mode The function is shown below, No.
User Manual of DP series Handheld Thermal Imaging Camera 2.1.3.3 Thermal AGC The function is shown below, No. Function Icon Description Choose high contract mode to view infrared 1 High contrast thermal image Choose legacy mode to view infrared thermal 2 Legacy image Choose gentle mode to view infrared thermal 3 2.1.3.4 Gentle image Color Palette ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera The function is shown below, No. 2.2 Function 1 Tyrian 2 White Hot 3 Black Hot 4 Rainbow 5 Glory 6 Iron 7 Hottest 8 Coldest Icon Description Settings The settings interface is shown below, 2.2.1 Language Select the language in the setting interface, click "OK & Homepage" to select the following different languages, ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera No. Language 1 English 2 Simplified Chinese 3 Spanish 4 French 5 Japanese 6 Korean 7 Russian 8 Arabic 9 Traditional Chinese ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.2 Emissivity Select the emissivity in the setting interface, and press "OK & Homepage" to set different emissivity of the object, or you can manually edit the emissivity. No. 2.2.3 Emissivity Value 1 Matt 0.95 2 Semi-matt 0.80 3 Semi-glossy 0.60 4 Glossy 0.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.3.1 Alarm above threshold Edit the upper limit alarm value, and then turn on the upper limit alarm switch (these two steps are in no particular order). If the temperature value in the screen area is higher than the set threshold temperature, an alarm icon will pop up on the screen. When the temperature value in the screen area is lower than the set threshold temperature, the alarm icon will disappear.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.3.2 Alarm below threshold Edit the lower limit alarm value, and then turn on the lower limit alarm switch (these two steps are in no particular order). If the temperature value in the screen area is higher than the set threshold temperature, an alarm icon will pop up on the screen. When the temperature value in the screen area is lower than the set threshold temperature, the alarm icon will disappear. 2.2.4 WiFi 2.2.4.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.5 LED Select the LED in the setting interface, and press "OK & Homepage" to turn the LED on or off. 2.2.6 More Select More in the setting interface, and press "OK & Homepage" to set more settings. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.6.1 Temperature Unit Temperature unit support below, Celsius Fahrenheit Kelvin 2.2.6.2 Storage In the storage option, you can view the current and used capacity of the internal storage memory, and you can choose to format the storage memory. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.6.3 Date Date setting can set the current date and time. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.6.4 Automatic Power Off Automatic power off can be selected for the following duration if without operating the camera 5 minutes 10 minutes 30 minutes 60 minutes Never 2.2.7 Temperature Bar This option can display or not display temperature bar in the home page. ©2021 All rights reserved Shenzhen Dianyang Technology Co., Ltd.
User Manual of DP series Handheld Thermal Imaging Camera 2.2.8 Brightness This option can adjust the brightness of the screen. 2.2.9 Restore factory settings Restore factory settings will perform default factory settings on the handheld thermal imaging camera. Please proceed with caution. 2.2.
User Manual of DP series Handheld Thermal Imaging Camera When the human body mode is on, a human head frame is displayed in the screen, let the head frame to aim at the people, by adjusting the distance between the DP series thermal camera and people, let the head of people to fill the head frame of DP series thermal camera, the measuring distance is approximately 0.75m. DP series thermal camera will start hottest tracing to measure human body temperature. The default fever temperature degree is 37.
User Manual of DP series Handheld Thermal Imaging Camera The accuracy of human body temperature measurement is higher than the general specification, in order to get the accurate temperature measurement result, please pay attention to the following operating items: The distance between the people and the DP series thermal camera is 0.75m. Make sure the DP series thermal camera working temperature to be 25°C. It is better to power on the DP series for 15 minutes then measuring.
User Manual of DP series Handheld Thermal Imaging Camera Maintenance 3.1 Battery Service and Replacement If the battery cannot be charged and needs to be replaced, please contact your local distributor for repair and replacement. 3.2 Calibration The camera is calibrated in the factory. If calibration is required, please contact your local distributor. 3.3 Clean If necessary, wipe the case with a damp cloth.
User Manual of DP series Handheld Thermal Imaging Camera Specification The DP series Infrared thermal imaging camera specification is below, Specification Parameter DP22 DP21 Resolution 320x240 220x160 Frequency band 8~14um 8~14um Frame rate 9Hz 9Hz NETD 70mK@25°C (77°C) 70mK@25°C (77°C) Field of view Horizontal 56°, vertical 42° Horizontal 35°, vertical 26° Infrared Lens 4mm 4mm Thermal Temperature range -10°C ~ 450°C (14°F ~ 842°F) -10°C ~ 450°C (14°F ~ 842°F) Imaging Temperat
User Manual of DP series Handheld Thermal Imaging Camera Simultaneous storage of infrared thermal Simultaneous storage of infrared thermal imaging, visible light and fusion images imaging, visible light and fusion images TIFF format, support full frame pictures TIFF format, support full frame pictures temperature analysis temperature analysis Windows platform analysis Provide professional analysis functions to Provide professional analysis functions to software analyze full pixels temperature an
User Manual of DP series Handheld Thermal Imaging Camera Appendix 5.1 Emissivity The emissivity of common materials is as follows, Material Emissivity Material Emissivity Asphalt 0.90 - 0.98 Cloth (black) 0.98 Concrete 0.94 Skin (human body) 0.98 Cement 0.96 Leather 0.75 - 0.80 Sand 0.9 Charcoal (powder) 0.96 Soil 0.92 - 0.96 Paint 0.80 - 0.95 Water 0.92 - 0.96 Lacquer (matte) 0.97 Ice 0.96 - 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 - 0.95 Glass 0.90 - 0.
User Manual of DP series Handheld Thermal Imaging Camera Technical Support Please access Shenzhen Dianyang Technology Co., Ltd. website to get more technical support, http://www.dianytech.com/ FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.