User's Manual

Install Guide XF1500P-XF1500CS4
XF1500P XF1500CS4
1 - Installation Sheet
1 - Mounting Plate
1 - Cover
1 - Potted Reader
Assembly
2 - Mounting Screws
1 - Cover Assembly Screw
1 - Installation Sheet
1 - Mounting Plate
1 - Cover
1 - Potted Reader Assembly
2 - Mounting Screws
1 - Cover Assembly Screw
1 - Pigtail with Connector
XF1500P & XF1500CS4
MOUNTING THE READER
1. Determine an appropriate mounting position on a single gang box or wall. Be sure to account
for any applicable ADA height requirements.
2. For a single gang box mount, attach the back-plate to the holes in the single gang box using
the screws provided.
3. For a wall mount, drill two mounting holes between 2.5” (63.5mm) and 3.5” (88.9mm) apart
on the mounting surface. Drill one 3/4” (19.1 mm) diameter cable hole for the pigtail wire
connection.
4. Connect the mounting plate to the wall using the screws provided.
5. Wire the unit according to the color code chart below ensuring that all connections are made
through the center hole in the mounting plate.
6. When installing the XF1500CS4 version of the reader plug the connector end of the pigtail
into the back of the reader.
7. Hook the top of the potted case assembly to the top of the mounting plate.
8. Swivel the unit down into place and snap the cover over the potted reader assembly.
9. Install the screw from the bottom to fix the cover to the potted case to the mounting plate.
CABLE CONNECTIONS
1. XceedID XF1500P readers are supplied with a 12 conductor cable pigtail.
2. XceedID XF1500CS4 readers are supplied with a connector with pigtail.
3. Connect this pigtail with the host/panel being careful to match the color of each wire with the
chart shown in Figure 1.
4. Use a DC power source between 5 volts and 16 volts.
5. Be sure the reader is properly grounded by attaching the ground wire to an earth ground
connection at the power supply or panel end of the cable.
Testing the Reader
1. Power up the reader. The LED will light followed by a beeper tone. This indicates that the
reader is ready.
2. Present a proper card or token programmed to operate the reader and a green LED flash will
indicate successful operation. Note that a red flash could simply indicate an incorrect match or
miss-programmed card/token rather than a faulty reader installation.
Additional Notes
• The voltage specification for these products is 5*-16VDC.
• Typical cable gauge ranges from 18 to 22 gauge. Check with your cable supplier to determine
the best choice for your application and installation distance

Summary of content (2 pages)