User's Manual

80mm
150mm
WYZE SCALE
QUICK START GUIDE
1 × Wyze Scale
4 × 1.5V AAA Batteries
1 × Quick Start Guide
26.6mm306mm
306mm
IN THE BOX
@wyzecam
NOTE
3
2
1
4
SETUP
Download the Wyze App and login or create an account.
App Store
Google Play
TIPS
No wet feet Don't wear socks
Don't keep your
knees together.
Wyze
LED DISPLAY
·Abnormal electrical impedance
measurement
·Connection error between the body
fat scale and the weight
measurement module.
·Overweight
·Current weight data is unstable
·Flash access error
·Error in firmware upgrade
·Connection error between the body
fat scale and the Wyze app.
·The battery is low, please replace
with new battery as soon as
possible.
·The battery is running out, please
replace with new battery.
1.Place the Wyze Scale on a hard, flat surface during use. Using
the scale on a soft surface like carpet or linoleum may impact the
accuracy of measurement.
2.Please make sure the information you entered in the Wyze app is
correct to get the most accurate results.
3.The primary user who installed the device can share it with up to
7 family members.
4.If the Wyze Scale is shared by users with similar weights, make
sure that the phone's Bluetooth is enabled and the scale is
nearby. If the scale is not connected to the Wyze app, data may
not be recorded accurately.
5. The primary user can set the "Connected Measurement Only"
and "Weight-Only" in the Wyze app.
6.Wyze Scale is intended for daily family use and not considered as
a medical device.
7.The following should use the Wyze Scale only as reference as the
body fat rate will be different from the average measurement:
People who are under 18 years of age, over 65 years old,
pregnant women, patients with osteoporosis or very low bone
density, patients with edema, or artificial dialysis.
Need Help?
Contact Our Support Team.
www.wyzecam.com/support
Monday-Friday 9AM-5PM PST
support@wyzecam.com
1-844-WYZECAM
Install 4 AAA batteries into the compartment. Please note
the positive and negative sign.
Add your device when prompted by the Wyze app. Please
make sure your phone's Bluetooth is enabled and the Wyze
Scale is nearby to establish connection.
After the connection is established, perform measurement
by standing on the scale with barefoot.
Never use this product in combination with medical electronic
devices such as:
(1) Medical electronic implants such as pacemakers.
(2) Electronic life support systems such as artificial heart/lungs.
(3) Portable electronic medical devices such as electrocardio-
graphs.
This product could cause these devices to malfunction posing a
considerable health risk to users of these devices.
INTENDED USE
The Wyze Scale is a precision electronic instrument intended for
adult use. The Scale utilizes ITO biology and pressure sensors
to measure body composition components automatically. The
measurements are displayed and stored on iOS or Android
device with date and time.
1.Do not stand on the edge of Scale, as you may fall over or
influence the accuracy of the measurement.
2.Do not use the Scale on a tiled or wet floor, as this may result in a
fall.
3.Make sure the surface of the Scale is clean and dry before you
step onto it, to prevent any slippage.
4.Treat your Scale with care. Do not drop it or jump on it. The Scale
is designed to be stood on; misuse or abuse may break the
electronic sensors, cause injury, or result in inaccurate
measurements.
5.Avoid using this Scale near strong magnetic fields, such as
microwave ovens, etc.
6.This device complies with part 15 of the FCC Rules. Its operation
is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
7.
Changes or modifications not expressly approved by the party
NOTE: This equipment has been tested and found to comply
with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that
interfer
ence will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment to an outlet on a circuit different from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for
help.
8.This device contains licence-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development
Canada’s licence-exempt RSS(s). Operation is subject to the
following two conditions: (1)This device may not cause
interference.(2)This device must accept any interference,
including interference that may cause undesired operation of the
device.
L’émetteur/récepteur exempt de licence contenu dans le présent
appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes :(1)L’appareil ne doit pas produire de
brouillage; (2)L’appareil doit accepter tout brouillage radioélec-
trique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
9.This equipment complies with IC RSS102 radiation exposure
limits set forth for an uncontrolled environment. This transmitter
must not be co-located or operating in conjunction with any
other antenna or transmitter.
Cet équipement est conforme aux limites d'exposition aux
radiations IC CNR102 établies pour un environnement non
contrôlé. Cet émetteur ne doit pas être situé au même endroit ou
fonctionner avec une autre antenne ou un autre émetteur.
WARRANTY INFORMATION
The Wyze scale is warranted to be free from defects in materials
and workmanship appearing within 1 year from the date of
purchase, when used in accordance with the instructions provided.
The above warranties extend only to the original retail purchaser. We
will, at our option, repair or replace without charge any product
covered by the above warranties. Repair or replacement is our only
responsibility and your only remedy under the above warranties.
1.Avoid high temperatures and irradiation.
2.If the Scale is stored close to freezing point, allow it to acclimate
to room temperature before use.
3.Remove the batteries if the Scale is not going to be used for 3
months or more.
4.Clean the Scale with a soft damp cloth. Do not use abrasive or
solvent-based cleaners, and never immerse it in water.
5.The Scale will maintain its safety and performance features for
at least 10,000 measurements or two years of use.
Please recycle where facilities exist. Waste
electrical products should not be disposed of with
household waste. Check with your local authority
or retailer for recycling advice
Keep dry
Refer to the User Manual
Warning
1. Product name: Wyze Scale
2. Model: HS2S
3. Product Size: 306×306×26.6mm
4. Product weight: 1.84kg
5. Classification: internally powered, type BF applied part (four
electrodes)
6. Power: 4×1.5V AAA batteries
Battery life: approx. 3 months with daily usage
7. Display units: Ib/kg
8. Compatibility: Android 5.0+, iOS 9.0+
9. Measurement range:
Body Weight: 11 lb-400 lb/5 kg-180 kg
Body Fat: 5.0%-65.0%
Scale resolution:0.lb/0.1kg
10. Accuracy:
Body Weight: ±1.1 lb/0.5 kg(11-110 lb / 5 kg-50 kg);
±1% (110-400 lb / 50 kg-180 kg)
Body Fat: ±1%
11. Operating temperature: 41°F-104°F (5°C - 40°C)
12. Operating humidity: 20 - 85%RH
13. Storage and transport temperature: -4°F-131°F (-20°C - 55°C)
14. Storage and transport humidity: ≤90%RH
SPECIFICATIONS
GENERAL SAFETY & PRECAUTIONS
CARE & MAINTENANCE
CONTRAINDICATION
Pregnant women need to consult their healthcare provider
before use. Some physical conditions could affect hydration
levels that may lead to inaccurate results. Please consult your
healthcare provider for more information.
EXPLANATION OF SYMBOLS ON UNIT
10.Under Industry Canada regulations, this radio transmitter may
only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and
its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that necessary for
successful communication.
11.Bluetooth® associated logos are registered trademarks owned
by Bluetooth SIG, Inc. and any use of such marks by Wyze Lab
Inc.is permitted under license.
Other trademarks and trade names are those of their respective
owners.
responsible for compliance could void the user's authority to operate
the equipment.

Summary of content (1 pages)