Datasheet

Dimensions: [mm]
35,4 ±1,0
21,3 ±1,0
0,8 defined airgap
19,2 ±1,0
Additional Features:
Safety Key to unlock 74271
STAR-CLIP Fixation 7427711
Applicable Cable Diameter: [mm]
4,5 - 8,0mm
Electrical Properties:
Properties Test conditions Value Unit Tol.
Impedance @ 25 MHz 1 turn Z 25 MHz 28 Ω ±25%
Impedance @ 25 MHz 2 turns Z 25 MHz 90 Ω ±25%
Impedance @ 100 MHz 1 turn Z 100 MHz 100 Ω ±25%
Impedance @ 100 MHz 2 turns Z 100 MHz 400 Ω ±25%
Impedance @ 200 MHz 1 turn Z 200 MHz 190 Ω ±25%
Impedance @ 200 MHz 2 turns Z 200 MHz 900 Ω ±25%
Impedance @ 300 MHz 1 turn Z 300 MHz 250 Ω ±25%
Impedance @ 300 MHz 2 turns Z 300 MHz 1750 Ω ±25%
Impedance @ 500 MHz 1 turn Z 500 MHz 345 Ω ±25%
Impedance @ 500 MHz 2 turns Z 500 MHz 1100 Ω ±25%
Certification:
RoHS Approval Compliant [2011/65/EU&2015/863]
REACh Approval Conform or declared [(EC)1907/2006]
Halogen Free Conform[JEDEC JS709B]
Halogen Free Conform [IEC 61249-2-21]
General Information:
Temperature during mounting
process
+15 °C up to +35 °C
Operating Temperature -25 up to +105 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 75 % RH
Storage Conditions (for single
parts)
15 °C up to +35 °C; 45 % up to 65 %
Test conditions of Electrical Properties: +20 °C, 33 % RH if not specified differently
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
NFi 003.000 2020-05-20 DIN ISO 2768-1m
DESCRIPTION
WE-STAR-GAP Snap Ferrite for RF
applications
ORDER CODE
74271633
BUSINESS UNIT STATUS PAGE
eiSos Valid 1/6
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.