Cover Material Carbon Steel
Actuator Material LCP
Actuator Flammability Rating UL94 V-0
Actuator Color Salmon
Frame Material PPA
Frame Flammability Rating UL94 HB
Frame Color Black
Contact Material Stainless Steel
Contact Plating Silver
Terminal Material Copper Alloy
Terminal Plating Silver
Material Properties:
Properties Test conditions Value Unit Tol.
Rated Current I
R
50 mA
Rated Voltage U
R
12 V (DC)
Contact Resistance Initial R 100 max.
Contact Resistance After Life
Test
R 2 Ω max.
Insulation Resistance R
ISO
500 V (DC) 100 min.
Withstanding Voltage 1 min 250 V (AC)
Bounce 10 ms max.
Electrical Properties:
Properties Value Unit Tol.
Operation Force 360 g ±80g
Life Cycle 200000 Times
Stroke 0.25 mm +0.2mm/-0.1mm
Mechanical Properties:
Operating Temperature -40 up to +85 °C
Storage Conditions (in original
packaging)
< 40 °C ; < 75 % RH
Moisture Sensitivity Level (MSL) 1
General Information:
Properties Value
Packaging Bulk
Packaging Unit Qty. 500
Packaging Properties:
Würth Elektronik eiSos GmbH & Co. KG
EMC & Inductive Solutions
Max-Eyth-Str. 1
74638 Waldenburg
Germany
Tel. +49 (0) 79 42 945 - 0
www.we-online.com
eiSos@we-online.com
CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION
METHOD
eLin 002.000 2018-12-03 DIN ISO 2768-1m
DESCRIPTION
WS-TATU THT Tact Switch
ORDER CODE
431256083736
SIZE/TYPE BUSINESS UNIT STATUS PAGE
6 x 6 mm Right Angled eiCan Valid 2/7
This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH
& Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety
must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance.