Smart Mold Counter WIZCoN User Manual WIZCONNECTED Inc. 2nd Floor, Seongbo Bldg.
Contents 1. 2. 3. 4. 5. General………………………………………………………………………. 3 Connecting with the repeater……………………………………………… 4 LCD display massages……………………………………………………. .5 Dimensions…………………………………………………………………..
1.General The counter is used to count the number of cycles of injection molds, press tools, die castings or other devices performing cyclic operations. The counter is inactive and automatically activates when the counter is installed on the mold surface. Using the counter's mode switch to set up a repeater to be linked, it is possible to communicate with the linked repeater. The counter is basically active, or mounted on the mold surface, and can only be counted while the Active Switch is pressed.
Technical parameters 1. 2. 3. 4. 5. 6. Core: ARM Cortex M3 32bit Communication: IEEE 802.15.4 USN Sub-GHz 7-digit 7-Segment Display 6times/sec Shot cycle 3.6Volt Li-SoCl2(2/3AA 1650mA×2pcs) 5years battery life(8times/day) 7. Working temperature -20~+85℃(-4℉~185℉) 8. Dimensions 36.5 × 58 × 27 mm 9. Mounting screws; - M4 × 25mm Hex wrench bolt(Counter) - M4 × 10mm Hex wrench bolt(Magnet) General information The counter is inactive upon delivery.
3. LCD display messages The default count display screen. When the counter is detected the magnet in an active state, the count value is increased and displayed on the screen.
If user press the mode switch button for more than 2 seconds, the counter’s ID will be displayed and can enter the setting menu. Enter the setting menu, press the mode switch button short to move to "LEAVE" menu, and set when the mode switch button is pressed twice. It is an item that must be selected from the counter to enable communication with the repeater after channel synchronizing. * If the counter is interlocking with the repeater, the antenna icon disappears when "LEAVE" is set.
Antenna icon is displayed when the counter is communicating with repeater through channel settings. 4.
Magnet dimensions 5.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. There is one statement for this product: The device must carry a label stating "FCC ID: XXXXXXXXX”. Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance.