WT-9001 IP65 G GS SM MR Re em mo otte eC Co on nttrro oll A An nd d A em m Alla arrm mS Sy ysstte User Manual & Setting Instructions W R R R W T U A C O P O A T O N S D N B H D WIIIT TU UR RA AC CO OR RP PO OR RA AT TIIIO ON NS SD DN NB BH HD D
WT-9001 IP65 GSM Remote Control And Alarm System WT-9001 IP65 GSM REMOTE CONTROL AND ALARM SYSTEM WIRING DIAGRAM DESCRIPTION WT-9001 IP65 – USER MANUAL – Rev.3.1 – Technical Support: technical@witura.
WT-9001 IP65 GSM Remote Control And Alarm System Example of Trigger Input Connections Example of Controlling Output Connections WT-9001 IP65 – USER MANUAL – Rev.3.1 – Technical Support: technical@witura.
WT-9001 IP65 GSM Remote Control And Alarm System PACKAGE CONTENTS 1) 1 pc IP65 Enclosure 2) 1 pc WT-9001 Main Board with GSM Module mounted 3) 1 pc Power Adapter 4) 1 pc Battery Backup 5) 1 pc GSM Antenna 6) 1 pc LCD Display for Assisting in Programming CONTENTS 1. Introduction……………………………………………………………………………………………………………………5 2. Features…………………………………………………………………………………………………………………………5 3. Characteristic……………………………………………………………………………………………………………5 4. Installation Instruction………………………………………………………………………………………………8 5.
WT-9001 IP65 GSM Remote Control And Alarm System 1. INTRODUCTION WITURA WT-9001 IP65 GSM Remote Control and Alarm System allow you to use your mobile phone to monitor and control your business from any location. Its alarm facilities provide a flexible way to distribute critical alarm information to any number of mobile phone users. More versatile than a pager system. WT-9001 IP65 provides detailed alarm messages, secure alarm acceptance, full alarm reporting and even remote process control.
WT-9001 IP65 GSM Remote Control And Alarm System 3.1 Standalone Operation Housed in the weather and desk proof IP 65 enclosure complete with internal industrial modem, monitoring controller and flexible operating firmware. It is very easy to setup, install and use. 3.2 8 Digital Inputs Most equipment today does provide some form of alerting signal to interface to monitoring devices from reporting of various malfunction or abnormalities.
WT-9001 IP65 GSM Remote Control And Alarm System 3.4 Querying Inputs And Outputs Status Authorized groups can also query the status of an input or output. This is very useful feature to determine the present status of an input or output. The enquirer need not wait for an alarm to happen in order to receive the given I/O status. 3.5 Turning On/ Off Device Remotely Authorized users can send a SMS command to trigger on or off the digital output.
WT-9001 IP65 GSM Remote Control And Alarm System 3.9 Reliable Performance Besides running the necessary program to perform all the required functions, WT-9001 has diagnostic routines running alongside. Being a monitoring device, WT-9001 must have a very high operating reliability and stability. Every section of WT-9001 is monitoring each other. Should the modem fail to perform its required role, the controller will interrogate and restart the modem. 3.
WT-9001 IP65 GSM Remote Control And Alarm System 4.2 Installing Components: Antenna, LCD, Power Supply & SIM Card Installing the SIM Card Note: Installing the SIM Card. Please be sure the initial 4 digit PIN code of SIM card is disabled. This can be done by placing it in an unlocked Mobile phone and first checking if the SIM requested any PIN code. If this is the case the PIN code can be disabled using the security settings on the phone. Proceed as follows 1. Slide back the SIM door and lift it up 2.
WT-9001 IP65 GSM Remote Control And Alarm System You should install the WT-9001 in a place where there is GSM signal coming from the operator you want to use. Check it with a phone before proceeding with the installation. If you need to install the device in a place with little signal, you may consider using an external antenna that we may supply as an option to be purchased separately with 5m cable. 4.
WT-9001 IP65 GSM Remote Control And Alarm System 5. WT-9001 IP65 PROGRAMMING INSTRUCTIONS (via SMS Only) You can program the WT-9001 via SMS commands using your phone. Any programming command sent by SMS must be in CAPITAL letters. The fields between square brackets are parameters; do NOT enter the square brackets. When you send a command, you will receive the answer for the first time even if your GSM number is not in the administrator list.
WT-9001 IP65 GSM Remote Control And Alarm System OK WT-9001 And then the WT-9001 will reply a message back to you that the administrator number has been added. Example of Returned Message: TEL1=1111222233 Note: Programming the administrator numbers is necessary in order to operate all other functions and to receive text alerts when the relays activated 5.
WT-9001 IP65 GSM Remote Control And Alarm System Text Command: *RLY[N]#XXXXX N stands for Output number 1 - 8 XXXXX stands for 5 digits value: The number of seconds Example: To turn on the output relay number 5 for 1 hour, you can send the following text message to the unit. *RLY5#03600 Example of Returned Message: RELAY5=03600 Note: Sending the following SMS Message to unit will switch off the relay *RLY5#00000 5.3.
WT-9001 IP65 GSM Remote Control And Alarm System 5.3.3 SETTING THE RECIPIENT OF RELAY OFF ALERT The unit can generate text alerts to all 20 of the administrator’s Mobile phone numbers when the relay has turned off. To set the administrator to receive this alert, you would send the following commands by SMS message to the unit.
WT-9001 IP65 GSM Remote Control And Alarm System Example: To turn on input number 1, you can send the following text message to the unit. *CTR1#1 Sending the following SMS Message to unit would mean input 1 will be turned off *CTR1#0 The 1 indicates the ON command and the 0 (zero) indicates the OFF command 5.4.
WT-9001 IP65 GSM Remote Control And Alarm System Example of Returned Message: RER2=3,2,2,2,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0; 5.4.3 Editing the Input Alert Message For (When Input gets High Pulse) The Input Alert Message can be edited and programmed up to 100 characters long. You can change the displayed text by sending the following commands by SMS message to the unit.
WT-9001 IP65 GSM Remote Control And Alarm System 5.4.5 Setting the Counter Alert Value For Inputs An alert message will be sent when the increment of alarm counter reaches the alert value (Default: 500). It is possible to set the alert value up to maximum value of 65535 times. To set the counter alert value of input, you can send the following commands by SMS message to the unit.
WT-9001 IP65 GSM Remote Control And Alarm System Function 2: • Function as pulse counter • Activate the output relay number (according to which input number applied) to stay on • Sends a counter alert message once alarm counter reaches the alert value • Audible alarm will sound if the alarm function is turned on (*ALM[N]#1) Function 3: • • Function as pulse counter Activate the output relay number (according to which input number applied) to stay on • Sends a programmable input alert message (*ST
WT-9001 IP65 GSM Remote Control And Alarm System Function 7: • Sends a programmable input alert message (*STR[N]#) once input triggered Function 8: • Function as pulse counter • Sends a programmable input alert message (*STR[N]#) once input triggered • Sends a programmable input alert message (*STO[N]#) once input returned to normal • Audible alarm will sound when input return to normal Note: It is required to reset the Counter Alert Value (*CLA#) each time you change the input function.
WT-9001 IP65 GSM Remote Control And Alarm System Example: When *ALTM#03600 is applied, means the audible alarm will sound for 1 hour when triggered 5.5.3 Power Down Alarm The system has the function to send a text alert and also sound the audible siren in the event the main power is lost and the system is relying on battery back up. It is also possible to activate and also deactivate this function by sending the unit a SMS Message.
WT-9001 IP65 GSM Remote Control And Alarm System Example of Returned Message: REAC=2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1; 5.5.5 Anti-Theft Feature The system has an anti-theft function that can used to detect the person who hijacks the WT-9001 device. It allows the owner to identify the hijacker’s SIM Card number by sending a warning message to the programmed owner’s number when the SIM card has been switched.
WT-9001 IP65 GSM Remote Control And Alarm System Example: When SIM card has been changed, it will generate 3 SMS to administrators 1, 2, 3 and 1 SMS to the rest, you would send the following SMS message to the unit. *REAT#3,3,3,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1; Example of Returned Message: REAT=3,3,3,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1; 5.6 MISCELLANEOUS SETTINGS 5.6.1 Inquire All Programmed Administrator Numbers To check all the administrator number in the list, simply send the following SMS command.
WT-9001 IP65 GSM Remote Control And Alarm System 5.6.4 Reading The Alarm Time Value It is possible to read the alarm time value by sending the following SMS command to the unit. Send the following SMS Command: *ALT?# 5.6.5 Reading The Total Increment Counter Value To read the total increment counter value, you can send the following SMS message to the unit. Text Command: *COU?# 5.6.
WT-9001 IP65 GSM Remote Control And Alarm System 5.6.8 Sound The Audible Alarm Manually It is possible to sound the alarm manually by sending the following SMS command to the unit, which remain active for the period of time set. Text Command: *ALNF#X X stands for ON (1) or OFF (0) value When *ALNF#1 is applied, means audible alarm will sound. When *ALNF#0 (Default) is applied, means audible alarm will turn off. 5.6.
WT-9001 IP65 GSM Remote Control And Alarm System 5.6.11 Setting The Password For Reset Command To setup a password for reset command, you can send the following SMS command to the unit. Text Command: *PAWO#XXXXXX XXXXXX stands for 6 digits password: 123456 (Default) Example: To change the password to 654321, you would send the following SMS command to the unit. *PAWO#654321 5.6.
WT-9001 IP65 GSM Remote Control And Alarm System 5.6.13 Reset The WT-9001 (Method 2) To reset the unit using this method, you will need to give a pulse at the input 1 by supplying a DC 12 – 40V and turn on the unit. Once turn on, the LCD displays… Pulse Counter REST>>? 00 00 Timer At this time, the timer will start and you will need to trigger the input for 5 times (by disconnecting the DC voltage at the input and connect it again X5) within 8 seconds.
WT-9001 IP65 GSM Remote Control And Alarm System REST-D OK The unit is reset successfully. 5.6.14 Setting The Function Of Opening & Closing Time For Output Relay The system has the function to activate the relay for a specific time and then be deactivated for a specific time in a repeating process. To set the opening & closing time of the relays, you can send the following SMS command to the unit. Note: This function only applied in input function 5 and 6.
WT-9001 IP65 GSM Remote Control And Alarm System 5.6.16 Setting the Output Relays to Supply Voltage or use Dry Contact when Activated To set the output relays to supply DC voltage when activated, please adjust the jumper according to the below diagram Note: The Relays will supply DC voltage only according to the output DC voltage of adapter used. To set the output relays to dry contact (Default) when activated, please adjust the jumper according to the below diagram WT-9001 IP65 – USER MANUAL – Rev.3.
WT-9001 IP65 GSM Remote Control And Alarm System 6. TECHNICAL SPECIFICATIONS \ Item Description Model WT-9001 Operating Voltage 15VDC, 2W No of Inputs 8 Digital protected Inputs No of Outputs 8 Relay Outputs - 0.3A/125 ACV, 0.3A/110 DCV Communication Port GSM Modem GSM 900/1800Mhz or GSM 850/1900Mhz Humidity Less Than 80% RH Operating Temperature 0°C to 55°C Physical size 225 x 186 x 70 mm Weight 1.