WT-1010 G GS SM MF Fo orr A Alla arrm mS Sy ysstte em m User Manual W R C O R O R O N S D N W T U A P A T B H D SD OR NS DN NB WIIIT TU UR RA AC CO RP PO OR RA AT TIIIO ON BH HD D
WT-1010 GSM For Alarm System SKETCH OF THE WT-1010 ANTENNA The antenna must be POWER INDICATOR well (RED) connected before The turn on the terminal indicator is illuminated when main power is present NETWORK INDICATOR (GREEN) The indicator is illuminated when the terminal is connected to GSM Network INSTALLATION & CONNECTION OUTPUT TEL PORT 1 (ALARM INPUT) TEL PORT 2 Connect the RS232 DB15 female cable Connect to Alarm Panel / also Connect to PSTN Line to the terminal for controlling o
WT-1010 GSM For Alarm System WIRING DIAGRAM A (Main Unit) WIRING DIAGRAM B (DB15 Female Cable) WT-1010 – User Manual – Rev. 3.1 - Technical Support: technical@witura.
WT-1010 GSM For Alarm System Please Check The Following Packing List Items WT-1010 Main Unit Telephone Line DB15 (F) Cable Power Adapter 5m GSM Terminal Antenna User Manual 1. Quantity 1 1 1 1 1 1 Unit Set Pcs Pcs Pcs Pcs Copy Introduction to the WT-1010 GSM For Alarm System The WT-1010 GSM Terminal is a wireless communicator for alarm and fire panels that uses the cell phone network (GSM) to transmit alarms and other panel event.
WT-1010 GSM For Alarm System 2. 1. Main Features Of The WT-1010 Panel compatibility: Allows any contact ID alarm panel to transmit alarms over GSM using the GSM voice channel 2. Works over the GSM cell phone networks Units can be used wherever there is cell phone coverage 3. Telephone line backup: WT-1010 give priority to the lowest cost network. WT1010 uses the telephone line as the main transmission line and uses the GSM voice channel as backup WT-1010 – User Manual – Rev. 3.
WT-1010 GSM For Alarm System 4. The WT-1010 units can continuously watches if a Contact ID is directed towards the security monitoring station through the wired or GSM network, and if either of the preset report codes is noticed, it sends an appropriate SMS message with definable text to a mobile phone numbers. Using this function, the owner can get instant SMS messages not only of alarms but also every event of closing/ opening. 5.
WT-1010 GSM For Alarm System 2. SIM Card: Disable the PIN code and set it to 1234 (default) For Transmitter Mode (Data or SMS): as with any transmitter, it requires an identifier, receiver telephone numbers, etc (refer to the complete information on Programming page) 3. Line Input: Connect the line input to the PSTN or ISDN network. 4. Outputs (Back-Up Mode): Connect the RS232 DB15 to additional remote controlling outputs. 5.
WT-1010 GSM For Alarm System For Example: ZONE4 is connected to a electrical door, when there is intruder or the electrical door is opened illegally, WT-1010 will receive short-circuit impulse on ZONE4 and will automatically send a signal to the monitoring station and also send a SMS to notify the owner. Inputs and Outputs Wiring Diagram 3.3 Installing The SIM Card Note: Installing the SIM Card. Please be sure the initial 4 digit PIN code of SIM card is disabled.
WT-1010 GSM For Alarm System Proceed as follows: 1. Slide back the SIM door and lift it up 2. Slide the SIM card into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3. Close the SIM door 4. Slide the SIM door to lock the SIM card in place 3.
WT-1010 GSM For Alarm System 3.5 Phone Calls From The Attached Telephone Set Connect to TEL1 After the GSM module is connected to the GSM network, an attached fixed line phone can be used to make calls. If you pick up the phone, you will hear a dial tone. Simply dial the number you want to call (as if you are dialing from a normal fixed line phone). You can also dial the WT-1010 unit’s phone number from another phone, and its attached phone will ring as a normal landline phone would.
WT-1010 GSM For Alarm System 4.1 Reset The WT-1010 It is advised that you should reset the WT-1010 unit before proceeding to the below programming section. To reset the unit, you can send the following command by SMS to the unit. Text Command: *WLTE#123456 4.2 Programming The Administrator/ Central Station Number The 8 administrator/central station numbers can be programmed with a text command via SMS.
WT-1010 GSM For Alarm System Example: When *SECT#11110000 is applied, means only administrator 1, 2, 3 and 4 will receive alert messages. Note: You can only put 1 in the first 4 digits of the text command if there are only phone numbers stored in #TEL1, #TEL2, #TEL3 and #TEL4. The rest should be 0. When *SECT#00000000 is applied, means no SMS report. 4.
WT-1010 GSM For Alarm System Example: When *SETM#08:30:15 is applied, the time 08:30:15 will be displayed on the LCD screen. 4.6 Turn Off the feature of Password Request when Accessing the System By default every time calling the system, it will prompt you to input a login password to gain access to the system. To turn off this feature, you can send the following SMS command to the unit.
WT-1010 GSM For Alarm System 4.8 “PSTN Failure” Settings 4.8.1 Enable/Disable the function of Dialing the programmable Administrator/Central Station number when PSTN Failed To program the unit to dial the programmed administrator/central station number when PSTN failed, you can send the following SMS command to the unit. Text Command: *PSC?#X X stands for ON (1) or OFF (0) value When *PSC?#1 is applied, it will dial the administrator/central station number when PSTN failed.
WT-1010 GSM For Alarm System 4.8.3 Auxiliary PSTN Fail Output Facility via PIN15 In additional to the alarm and text alert on PSTN fail the system also has a second permanent +V output continuously via PIN15 output of the unit which will remain available for the period of PSTN unavailable. To turn On/Off this function, you can send the following SMS command to the unit. Text Command: *PSOF#X X stands for ON (1) or OFF (0) value When *PSOF#1 is applied, means it has +V output via PIN15 when PSTN failed.
WT-1010 GSM For Alarm System 4.9 4.9.1 “AC Failure” Settings Enable/Disable the function of Dialing the programmable Administrator/Central Station number when AC Failed To program the unit to dial the programmed administrator/central station number when AC failed, you can send the following SMS command to the unit. Text Command: *ACCA#X X stands for ON (1) or OFF (0) value When *ACCA#1 is applied, it will dial the administrator/central station number when AC failed.
WT-1010 GSM For Alarm System 4.9.3 Turning the Audible Alarm On/Off for AC failure The system has the function to sound the connected audible siren when power failure. This output is available on the connection PIN4 and ground on the main board. To turn On/Off this function, you can send the following SMS command to the unit. Text Command: *ADAL#X X stands for ON (1) or OFF (0) value When *ADAL#1 (Default) is applied, means audible alarm will sound when AC failed.
WT-1010 GSM For Alarm System 4.10.2 Enable/Disable the SMS Report of Auto Test The system has the function of sending auto test report by SMS to the programmable administrator/central station number. It is possible to enable or disable this function by sending the following SMS command to the unit.
WT-1010 GSM For Alarm System 4.10.4 Enable/Disable the function of Dialing the programmed Administrator number/Central Station number for Auto Test To program the unit to dial the programmed administrator/central station number for auto test report, you can send the following SMS command to the unit. Text Command: *DTC?#X X stands for ON (1) or OFF (0) value When *DTC?#1 is applied, it will dial the programmable administrator/central station number at the programmed report time interval.
WT-1010 GSM For Alarm System 4.11.2 Enable/Disable the function of generating an Alert Message when Inputs Triggered (Open) upon High Pulse The system has the function to send alert message to the user in the event of input triggered. It is possible to enable or disable this function by sending the following SMS command to the unit.
WT-1010 GSM For Alarm System 4.11.4 Editing the Inputs Alert Messages (Up to 50 Characters) The Input Alert Message can be edited and programmed up to 50 characters. You can change the displayed text by sending the following commands by SMS message to the unit. Text Command: *USE[N]#XXXXXX… N stands for Input number 1 – 3 XXXXXX… stands for alert message content Example: If you want the alert message to display “Garage Opened!” when input 1 triggered; you would send the following SMS message to the unit.
WT-1010 GSM For Alarm System 4.12 Output Settings 4.12.1 Activate Output Relay to Stay On for a Specific Time To activate the output relay, you can send a text command via SMS specifying the number of seconds the output should stay on to the unit.
WT-1010 GSM For Alarm System 4.13 Setting the Delay Time when Transmitting an Alarm The unit can be set to transmit an alarm within a specific time. To program the delay time of transmitting the alarm, you can send the following SMS command to the unit. Text Command: *DATM#XXXXX XXXXX stands for 5 digits value: the number of seconds (00000-65535) When *DATM#00007 is applied, the system will send out the alarm to the programmable administrator/central station number within 7 seconds from the alarm panel.
WT-1010 GSM For Alarm System 4.16 Setting for Adding 0 (Zero) when Transmitting an Alarm The system has the function of adding 0 automatically when dialing the number from the alarm panel. It is possible to enable or disable this function by sending the following SMS command to the unit. Text Command: *ZEAR#X X stands for ON (1) or OFF (0) value When *ZEAR#1 is applied, it will add 0 in front every time it dials the number from the alarm panel.
WT-1010 GSM For Alarm System 4.18.2 Inquire the status of the Recipients that will receive Alert Messages To inquire the status of the recipients that will receive alert messages, you can send the following SMS command to the unit. Text Command: *ASRE# 4.18.3 Checking Signal Strength To check the signal strength of the unit, you can send the following SMS command to the unit. Text Command: *CSQ?# 4.18.4 Inquire Time Status To check the time status, you can send the following SMS command to the unit.
WT-1010 GSM For Alarm System 4.18.6 Setting for GPRS function The system has the function of GPRS which can be used for data transmission. This function is available on the connection PIN2 (TXD) and PIN3 (RXD). It is possible to activate this function by sending the following SMS command. Text Command: *LINE# When *LINE# is applied, this unit is ready to be used for GPRS (For Transmitting Data Only) Note: To turn off this function or switch back to normal mode simply restart the unit. 4.18.
WT-1010 GSM For Alarm System 4.18.9 Changing the Login Password It is possible to change the login password by sending the following SMS command. Text Command: *PAWO#XXXXXX XXXXXX stands for 6 digits New Password 4.18.10 Permanent +V Output Facility There is a permanent +V output when the WT-1010 is power on. This output is available on the connection PIN8 and ground on the main board. The output voltage is according to power supply used on WT-1010. It can be used to power on other facility or device. 5.
WT-1010 GSM For Alarm System 1) Enter Programming Mode Pick up the handset or press hands free, press **123456# to enter programming mode. If the password is entered correctly, you should see “HAND FREE…” displayed on WT-1010 screen. Now you may proceed with programming settings. ENTER SETTING… When pick up the handset ENTER OK SETTING… Password entered correctly HAND FREE… Programming Mode 2) Changing the Login Password To change the 6 digits login password, you can press *0* to proceed.
WT-1010 GSM For Alarm System NEW WORD: 3) OK Programming the Administrator/Central Station Number Continue pressing *1* to start programming the administrator number 1 TEL: 1# TEL: 13232353646 1# Enter administrator number and ended with # TEL: OK 1# Number programmed successfully You may continue to program administrator number 2, 3, 4, 5, 6, 7 and 8 by pressing *2*, *3*,*4*, *5*, *6*, *7*, *8* 4) Deleting the Administrator/Central Station Number Example: To delete the programmed administrator num
WT-1010 GSM For Alarm System TEL: OK 1# 5) Programming the Area Code To program area code, you can press *9* to proceed. NEW AREA: NEW AREA: 03 Enter area code and ended with # NEW AREA: OK Area code programmed successfully 6) Setting the Access Control for Administrator Note: It is advised that the owner should set the system to allow programming access for administrators only after programmed the Administrator numbers. To set the access control for administrator, you can press *11* to proceed.
WT-1010 GSM For Alarm System ANDY–ON&OFF: OK 7) Setting the function of Adding 0 (Zero) when Transmitting an Alarm To set the function of adding 0, you can press *12* to proceed. ZEAR–ON&OFF: ZEAR–ON&OFF: 1 To enable this function simply press 1# To disable this function simply press 0# ZEAR–ON&OFF: OK 8) Enable/Disable the feature of Password Request when Login the System To enable/disable this function, you can press *13* to proceed.
WT-1010 GSM For Alarm System PASSWORD–ON&OFF: OK 9) Setting the Function of Adding Area Code when Transmitting an Alarm To turn on/off this function, you can press *14* to proceed. AREA–ON&OFF: AREA–ON&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# AREA–ON&OFF: OK 10) Reset the Main Unit To reset the unit, you can press *15* to proceed. REST–ON&OFF: REST–ON&OFF: 1 To reset the unit simply press 1# To turn back simply press 0# WT-1010 – User Manual – Rev.
WT-1010 GSM For Alarm System REST–ON&OFF: OK 11) Time Setting To setup time, you can press *16* to proceed. TIME: TIME: : : 8 : 30 : 00 Example: To set the time at 8.30am Simply input digits and ended with # TIME: 8 : 30 : 00 OK 12) Setting the Auto Test Report Time Interval To set the auto test report time interval, you can press *17* to proceed. DSTM: DSTM: : : 12 : 00 : 00 Example: To set the auto test report time at 12.
WT-1010 GSM For Alarm System DSTM: 12 : 00 : 00 OK 13) Setting the Recipient that will receive Alert Messages To do this setting, you can press *18* to proceed. SECT: SECT: 11111111 Example: To turn on this function for all recipients Simply input 11111111# SECT: 11111111 OK Note: Only Value: ON (1) or OFF (0) is allowed 14) Inquire the status of the Recipients that will receive Alert Messages To inquire the status of the recipients, you can press *19* to proceed.
WT-1010 GSM For Alarm System 15) Inquire the signal strength To inquire the signal strength, you can press *20* to proceed. CSQ <23> The signal strength will be displayed on screen 16) Activate Output Relay to stay on for a specific time To activate output relay 1 to stay on for a specific time, you can press *21* to proceed.
WT-1010 GSM For Alarm System IN1: OP: 1 CL: 1 AL: 1 CA: 1 Example: Setting the input 1 to generate an SMS, call the administrators and sound the audible alarm when it triggered.
WT-1010 GSM For Alarm System 19) Enable/Disable the generation of SMS Report for Auto Test To turn on this function, you can press *28* to proceed. DTIMEM – ON&OFF: DTIMEM – ON&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# 20) Setting for Calling a group of administrator numbers To program the unit to dial a certain group of numbers when PSTN/AC failed or Auto Test, you can press *29* to proceed.
WT-1010 GSM For Alarm System 21) “PSTN Failure” Setting To do this setting, you can press *30* to proceed. PST: ME: OU: AL: CA: PST: ME: 1 OU: 1 AL: 1 CA: 1 Example: Setting the unit to generate an Alert Message, call the administrators, generate a pulse (+V) and sound the audible alarm when PSTN failed.
WT-1010 GSM For Alarm System Note: “ME” stands for generation of SMS when PSTN failed “OU” stands for generation of pulse (+V) when PSTN faile “AL” stands for sounding the audible alarm when PSTN failed “CA” stands for calling the administrators when PSTN failed Value: ON (1) or OFF (0) 23) Inquire all Administrator numbers To inquire all administrator numbers, you can press *32* to proceed.
WT-1010 GSM For Alarm System 25) Setting the Delay Time when Transmitting an Alarm To set the delay time, you can press *34* to proceed. BOHAO: BOHAO: 00007 Example: To set the delay time at 7 seconds Simply press 00007# 26) Enable/Disable the GPRS function To enable the GPRS function, you can press *35* to proceed.
WT-1010 GSM For Alarm System ATACC: 9999 Example: To set the account number as 9999 Simply press 9999# Note: The account number must entered in 4 digits 6. 1. Technical Specifications Working condition Environment temperature: 0~+50°C Relative humidity: 10%~95% Air pressure: 86~106kpa Environment yawp: ≤60dB (A) 2. Working frequency: GSM900MHz/GSM1800MHz 3. Stability of frequency: better than 2.5PPM 4. Signal sensitivity: -103dBM 5. Transmit power: <2w 6. Power: 220v±15% AC 7.
WT-1010 GSM For Alarm System WARRANTY Witura Corporation Sdn Bhd warrantees all WT-1010 GSM For Alarm System against defective parts and workmanship for 1 year warranty. Witura Corporation Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch.